Failure Analysis of CO Shift Gas Heat Exchanger Tubes

被引:0
|
作者
Cao, Huaixiang [1 ]
Zhang, Hao [1 ]
Song, Mingda [1 ]
Shen, Xiaomin [1 ]
机构
[1] Shandong Special Equipment Inspect Inst, High Tech Zone, 939 Tianchen RD, Jinan 250101, Shandong, Peoples R China
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Tubes of a heat exchanger in a chemical plant leaked frequently, and such tubes will be replaced in one or two years. Therefore, it is necessary to find the leak causes and put in place preventive measures. In this paper, analysis methods such as macroscopic examination, the chemical composition test, metallurgical structure analysis, scanning electron microscopy (SEM) observation, energy spectrum (EDS) and X-ray diffraction (XRD) analysis of corrosion products and condensate water analysis are described that were conducted to analyze the leak causes of the heat exchanger tubes. After analyzing operating parameters (temperature, pressure) and the structure of the bottom area of the heat exchanger, it was found that the heat exchanger tubes inlet was operating in the vapor dew point zone. The results indicate that process parameters (temperature, pressure) were not properly selected and there were substantial SO42- in the process of production. As a result of that dew point corrosion in the form of pitting corrosion and stress corrosion cracking (SCC) which caused the leak occurred on heat exchanger tubes. Finally, relevant preventive measures were recommended according to the analysis results.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Failure Analysis of Duplex Stainless Steel for Heat Exchanger Tubes with Seawater Cooling Medium
    Ardy, Husaini
    Albatros, Thomas
    Sumboja, Afriyanti
    METALS, 2023, 13 (07)
  • [22] Investigation of failure of tubes in a heat exchanger for corrosion of dissolved oxygen
    Huang, Song
    Chen, Jie
    Zhang, Wenpin
    Xiong, Shutao
    2019 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2020, 440
  • [23] Failure Assessment of Heat Exchanger Tubes Due to Grooving Corrosion
    Ranjbar, Khalil
    Sharifi, Emad
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (02) : 739 - 750
  • [24] The effect of plugging of tubes on failure of shell and tube heat exchanger
    Farrahi, G. H.
    Chamani, M.
    Kiyoumarsioskouei, A.
    Mahmoudi, A. H.
    ENGINEERING FAILURE ANALYSIS, 2019, 104 : 545 - 559
  • [25] Failure Assessment of Heat Exchanger Tubes Due to Grooving Corrosion
    Khalil Ranjbar
    Emad Sharifi
    Journal of Failure Analysis and Prevention, 2023, 23 : 739 - 750
  • [26] Failure analysis of BLC heat exchanger
    Kobayashi, H
    Yoshioka, T
    Takehana, T
    INTERNATIONAL JOURNAL OF FATIGUE, 1998, 20 (02) : 155 - 160
  • [27] Failure Analysis of Authentic Stainless Steel Tubes in a Vertical Fixed Shell–Tube Heat Exchanger
    Wang S.
    Xu S.
    Huang S.
    Journal of Failure Analysis and Prevention, 2018, 18 (2) : 405 - 412
  • [28] COMPREHENSIVE ANALYSIS OF HEAT EXCHANGER FAILURE
    Prochazka, Miloslav
    EUROPEAN NDT DAYS IN PRAGUE 2007: NDE FOR SAFETY, PROCEEDINGS, 2007, : 197 - 208
  • [29] Failure Analysis of a Heat Exchanger Shell
    Al-Shahrani, S.
    Al-Meshari, A.
    van Zyl, G. N.
    Ahmad, S.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2013, 13 (01) : 20 - 25
  • [30] Corrosion failure analysis for heat exchanger
    Jing, Hongyang
    Shang, Jin
    Xu, Lianyong
    Han, Yongdian
    Hanjie Xuebao/Transactions of the China Welding Institution, 2016, 37 (09): : 1 - 4