Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty

被引:11
|
作者
Stone, Andrea H. [1 ]
Sibia, Udai S. [1 ]
MacDonald, James H. [1 ]
机构
[1] Anne Arundel Med Ctr, Annapolis, MD USA
关键词
patient-specific instrumentation; Knee Society Scores; total knee arthroplasty; mechanical alignment; blood loss; MATCHED INSTRUMENTATION; ALIGNMENT; STANDARD; TRIAL;
D O I
10.1177/1553350618787074
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Patient-specific instruments (PSIs) were developed to improve mechanical axis alignment for patients undergoing total knee arthroplasty (TKA) as neutral alignment (180 degrees) is a predictor of long-term success. This study examines alignment accuracy and functional outcomes of PSI as compared with standard instruments (SIs). Methods. We retrospectively reviewed a consecutive series of TKA procedures using PSI. A total of 85 PSI procedures were identified, and these were compared with a matched cohort of 85 TKAs using SI. Intraoperative decision-making, estimated blood loss, efficiency, Knee Society Scores, and postoperative radiographs were evaluated. Results. One hundred and seventy patients with comparable patient demographics were reviewed. Eighty-one percent of the PSI procedures were within target (180 +/- 3 degrees) mechanical alignment, while the SI group had 70% of cases within the target plane (P = .132). Mean target alignment (2.0 degrees PSI vs 2.2 degrees SI, P = .477) was similar between groups. Twenty-seven percent of patients in the PSI group had surgeon-directed intraoperative recuts to improve the perceived coronal alignment. The change in hematocrit was reduced in the PSI group (8.89 vs 7.21, P = .000). Procedure time and total operating room time were equivalent. Knee Society Scores did not differ between groups at 6 months or at 1 year. Conclusion. Patient-specific instrumentation decreased change in hematocrit, though coronal alignment and efficiency were equivalent between groups. Surgeons must evaluate cuts intraoperatively to confirm alignment. Functional outcomes are equivalent for PSI and SI groups.
引用
收藏
页码:470 / 475
页数:6
相关论文
共 50 条
  • [41] Efficacy of Patient-Specific Instruments in Total Knee Arthroplasty A Systematic Review and Meta-Analysis
    Thienpont, Emmanuel
    Schwab, Pierre-Emmanuel
    Fennema, Peter
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (06): : 521 - 530
  • [42] Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation
    Martijn G. M. Schotanus
    Elke Thijs
    B. Boonen
    B. Kerens
    B. Jong
    Nanne P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1656 - 1661
  • [43] Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation
    Schotanus, Martijn G. M.
    Thijs, Elke
    Boonen, B.
    Kerens, B.
    Jong, B.
    Kort, Nanne P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) : 1656 - 1661
  • [44] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Meng Zhu
    Jerry Yongqiang Chen
    Hwei Chi Chong
    Andy Khye Soon Yew
    Leon Siang Shen Foo
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2567 - 2572
  • [45] Functional Outcome and Quality of Life After Patient-Specific Instrumentation in Total Knee Arthroplasty
    Prakash, Jatin
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 923 - 924
  • [46] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Zhu, Meng
    Chen, Jerry Yongqiang
    Chong, Hwei Chi
    Yew, Andy Khye Soon
    Foo, Leon Siang Shen
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (08) : 2567 - 2572
  • [47] Functional Outcome and Quality of Life after Patient-Specific Instrumentation in Total Knee Arthroplasty
    Chen, Jerry Yonggiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1724 - 1728
  • [48] Accuracy of Patient-Specific Instrument for Cylindrical Axis Implementation in Kinematically Aligned Total Knee Arthroplasty
    Kim, Kwang-Kyoun
    Song, Jaehwang
    CLINICS IN ORTHOPEDIC SURGERY, 2023, 15 (05) : 760 - 769
  • [49] Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial
    Chun Hoi Yan
    Kwong Yuen Chiu
    Fu Yuen Ng
    Ping Keung Chan
    Christian Xinshuo Fang
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3637 - 3645
  • [50] Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial
    Yan, Chun Hoi
    Chiu, Kwong Yuen
    Ng, Fu Yuen
    Chan, Ping Keung
    Fang, Christian Xinshuo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3637 - 3645