Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation

被引:5
|
作者
Schotanus, Martijn G. M. [1 ]
Thijs, Elke [1 ]
Boonen, B. [1 ]
Kerens, B. [2 ]
Jong, B. [3 ]
Kort, Nanne P. [1 ]
机构
[1] Zuyderland Med Ctr, Dept Orthoped Surg & Traumatol, Dr H vd Hoffpl 1, NL-6162 AG Sittard Geleen, Netherlands
[2] AZ St Maarten, Mechelen, Belgium
[3] Zuyderland Med Ctr, Dept Radiol, Sittard Geleen, Netherlands
关键词
Patient-specific instruments; PSI; Revision; Partial knee arthroplasty; PKA; Unicompartmental knee arthroplasty; UKA; Total knee arthroplasty; TKA; CT-based; Outliers; Planning; Alignment; ALIGNMENT; REPLACEMENT; METAANALYSIS; CT; COMPONENTS; OUTCOMES; LEVEL; MRI;
D O I
10.1007/s00167-017-4674-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations > 3.0A degrees from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1A degrees (1.4A degrees). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. Prospective cohort study, Level II.
引用
收藏
页码:1656 / 1661
页数:6
相关论文
共 50 条
  • [1] Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation
    Martijn G. M. Schotanus
    Elke Thijs
    B. Boonen
    B. Kerens
    B. Jong
    Nanne P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1656 - 1661
  • [2] Revision of total knee arthroplasty with the use of patient-specific instruments: an alternative surgical technique
    Leon-Munoz, Vicente J.
    Parrinello, Andrea
    Lopez-Lopez, Mirian
    Martinez-Martinez, Francisco
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (08) : 795 - 806
  • [3] Patient-specific Instruments for Total Knee Arthroplasty
    Lachiewicz, Paul F.
    Henderson, Robert A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2013, 21 (09) : 513 - 518
  • [4] Patient-specific instruments in total knee arthroplasty
    Conteduca, Fabio
    Iorio, Raffaele
    Mazza, Daniele
    Ferretti, Andrea
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) : 259 - 265
  • [5] Patient-specific instruments in total knee arthroplasty
    Fabio Conteduca
    Raffaele Iorio
    Daniele Mazza
    Andrea Ferretti
    International Orthopaedics, 2014, 38 : 259 - 265
  • [6] A comparison of conventional and patient-specific instruments in total knee arthroplasty
    Kiriakos Daniilidis
    Carsten O. Tibesku
    International Orthopaedics, 2014, 38 : 503 - 508
  • [7] A comparison of conventional and patient-specific instruments in total knee arthroplasty
    Daniilidis, Kiriakos
    Tibesku, Carsten O.
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (03) : 503 - 508
  • [8] Total knee arthroplasty. Patient-specific instruments and implants
    Steinert, Andre F.
    Holzapfel, Boris M.
    Sefrin, Lukas
    Arnholdt, Joerg
    Hoberg, Maik
    Rudert, Maximilian
    ORTHOPADE, 2016, 45 (04): : 331 - +
  • [9] Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty
    Stone, Andrea H.
    Sibia, Udai S.
    MacDonald, James H.
    SURGICAL INNOVATION, 2018, 25 (05) : 470 - 475
  • [10] Reply to letter to editor: Patient-specific instruments in total knee arthroplasty
    Mazza, Daniele
    Conteduca, Fabio
    Iorio, Raffaele
    Ferretti, Andrea
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (06) : 1339 - 1340