Spatial resolution in PET and the effect of gamma-ray interaction depth in block detectors

被引:0
|
作者
St James, S [1 ]
Thompson, C [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ H3A 2T5, Canada
关键词
D O I
10.1118/1.2030972
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The spatial resolution in PET is poorer than that of CT or MRI. All modern PET scanners use block detectors, i.e. clusters of scintillation crystals coupled to four photomultiplier tubes (PMTs). Some of the loss of spatial resolution in PET is attributed to the use of block detectors, because a photon that interacts with one crystal in the cluster may be incorrectly positioned, resulting in blurring of the reconstructed image, called the “block effect”. We examined the effect of changing gamma‐ray interaction depth in the scintillation crystals in detectors from the CTI HR+ and GE Advance PET scanners. We postulated that the depth at which the gamma‐ray interacts may contribute to the “block effect” blurring. The “block effect” was measured for both detectors, and it was found to be 1.2 mm for the central crystals and negligible for the edge crystals in the CTI HR+ block. However, it was 0.9 mm in all crystals of the GE Advance detector. In the CTI HR+ detector, a depth dependence on the positioning of the event was observed, as was a dependence on the crystal location (edge vs. centre). In the GE Advance detector, no such dependence was observed. These results suggest that the depth of interaction of an annihilation photon may contribute to the block effect in detectors that use crystals cut from a single scintillation crystal (pseudo‐discrete crystals). In detectors that use discrete crystals no additional blurring as a function of gamma‐ray interaction depth in the detectors was observed. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2408 / 2408
页数:1
相关论文
共 50 条
  • [21] GAMMA-RAY IMAGING WITH GERMANIUM DETECTORS
    MAHONEY, WA
    CALLAS, JL
    LING, JC
    RADOCINSKI, RG
    SKELTON, RT
    VARNELL, LS
    WHEATON, WA
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1993, 97 (01): : 385 - 388
  • [22] Sensitivity of gamma-ray detectors to polarization
    Yadigaroglu, IA
    EXPERIMENTAL ASTRONOMY, 1997, 7 (03) : 221 - 237
  • [23] A realistic simulation of gamma-ray detectors
    Manfredotti, C
    Fizzotti, F
    Polesello, P
    Vittone, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 145 - 147
  • [24] ADVANCES IN CDTE GAMMA-RAY DETECTORS
    SERREZE, HB
    ENTINE, G
    BELL, RO
    WALD, FV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 404 - 407
  • [25] DIIODIDE CRYSTALS FOR GAMMA-RAY DETECTORS
    ZALETIN, VM
    NOZHKINA, IN
    FOMIN, VI
    SHUSTOV, NV
    PROTASOV, II
    SOVIET ATOMIC ENERGY, 1980, 48 (03): : 191 - 194
  • [26] Realistic simulation of gamma-ray detectors
    Univ of Torino, Torino, Italy
    Nucl Instrum Methods Phys Res Sect A, 1-2 (145-147):
  • [27] Testing the 130 GeV gamma-ray line with high energy resolution detectors
    Li, Ye
    Yuan, Qiang
    PHYSICS LETTERS B, 2012, 715 (1-3) : 35 - 37
  • [28] CZT detectors as MeV gamma-ray calorimeters with excellent position and energy resolution
    Jung, I
    Perkins, J
    Krawczynski, H
    Sobotka, L
    Komarov, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4383 - 4387
  • [29] Energy resolution of some new inorganic-scintillator gamma-ray detectors
    van Eijk, CWE
    Dorenbos, P
    van Loef, EVD
    Krämer, K
    Güdel, HU
    RADIATION MEASUREMENTS, 2001, 33 (05) : 521 - 525
  • [30] Effect of depth of interaction resolution on the spatial resolution of SIAT aPET
    Kuang, Zhonghua
    Zhang, Ling
    Ren, Ning
    Kinyanjui, Samuel M.
    Liu, Zheng
    Sun, Tao
    Hu, Zhanli
    Yang, Yongfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (22):