A realistic simulation of gamma-ray detectors

被引:5
|
作者
Manfredotti, C [1 ]
Fizzotti, F [1 ]
Polesello, P [1 ]
Vittone, E [1 ]
机构
[1] NATL INST NUCL PHYS,TURIN,ITALY
关键词
D O I
10.1016/S0168-9002(96)00329-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Simulation of gamma-ray semiconductor detector generally makes assumptions such as electric field uniformity, constancy of mobilities and trapping times respect to electric field, etc. At least a part of these assumptions are not valid. A way to overcome this problem is to measure the collection efficiency as a function of depth directly. By a particular version of the micro-IBIC technique we measured the collection efficiency on a section of a CdTe detector and we used the experimental data as input for the Monte Carlo code ISIDE for simulating pulse height spectra produced by Co-57. The results obtained by this more realistic approach are presented and can be compared both with other kinds of simulations and with available experimental data.
引用
收藏
页码:145 / 147
页数:3
相关论文
共 50 条
  • [1] Realistic simulation of gamma-ray detectors
    Univ of Torino, Torino, Italy
    Nucl Instrum Methods Phys Res Sect A, 1-2 (145-147):
  • [2] Simulation studies of CZT detectors as gamma-ray calorimeter
    Jung, I.
    Krawczynski, H.
    Komarov, S.
    Sobotka, L.
    ASTROPARTICLE PHYSICS, 2006, 26 (02) : 119 - 128
  • [3] Gamma-ray tracking detectors
    Lee, IY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 195 - 200
  • [4] GERMANIUM GAMMA-RAY DETECTORS
    PEHL, RH
    PHYSICS TODAY, 1977, 30 (11) : 50 - 60
  • [5] Simulation and experimental results on monolithic CdZnTe gamma-ray detectors
    d'Aillon, EG
    Gentet, MC
    Montémont, G
    Rustique, J
    Verger, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4451 - 4455
  • [6] Simulation and experimental results on monolithic CdZnTe gamma-ray detectors
    d'Aillon, EG
    Gentet, MC
    Montémont, G
    Rustique, J
    Verger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3096 - 3102
  • [7] The spatial response of CdZnTe gamma-ray detectors as measured by gamma-ray mapping
    Brunett, BA
    Van Scyoc, JM
    Schlesinger, TE
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 76 - 84
  • [8] COMPUTER-SIMULATION OF AN ARRAY OF GE DETECTORS FOR GAMMA-RAY IMAGING
    ARISTE, JEN
    ALBERNHE, F
    VEDRENNE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 357 (01): : 170 - 177
  • [9] Charge sharing on monolithic CdZnTe gamma-ray detectors:: A simulation study
    d'Aillon, Eric Gros
    Tabary, Joachim
    Gliere, Alain
    Verger, Loick
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 124 - 127
  • [10] APPLICATIONS OF GERMANIUM GAMMA-RAY DETECTORS
    SHIRLEY, DA
    NUCLEONICS, 1965, 23 (03): : 62 - &