Hybrid self-calibration method for reference surface elimination in subaperture stitching interferometry

被引:2
|
作者
Liu, WeiJian [1 ]
Gao, Zhishan [1 ]
Wang, Ruoyan [1 ]
Che, Xiaoyu [1 ]
Wang, Lingjie [2 ]
Lei, Lihua [3 ]
Guo, Zhenyan [1 ]
Yuan, Qun [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Xiao Lingwei Rd 200, Nanjing 210094, Jiangsu, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Key Lab Opt Syst Adv Mfg Technol, Changchun 130033, Peoples R China
[3] Shanghai Key Lab Online Test & Control Technol, Shanghai 201203, Peoples R China
基金
中国国家自然科学基金;
关键词
Subaperture stitching; Wavefront interferometry; Error elimination; LARGE FLAT;
D O I
10.1016/j.optcom.2022.128278
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Subaperture stitching interferometry (SSI) is an essential method for the map testing of large-aperture optical components. The surface map of a reference surface is a typical error source. In this study, we propose a hybrid self-calibration method to eliminate the reference surface error in SSI by combining the modified shift-rotation method and the maximum likelihood method. The traditional shift-rotation method is a general full-aperture absolute interferometric measurement that can retain localized irregularities. The shift-rotation operations are leveraged to generate a couple of subapertures covering the surface under test, whereby a ring of subapertures and a central subaperture are acquired by rotations and a lateral shift, respectively. The modified shift-rotation method is proposed to obtain the rotationally asymmetric components of the test surface in the ring of subapertures. The same components within the central subaperture are retrieved using the maximum likelihood method. Then, the rotationally symmetric components of the test surface are acquired using the least squares method, utilizing the measured data before and after the shift. Reference surface maps are sufficiently eliminated from the measured data. High-frequency components of the test surface are also retained, which engender high-accuracy SSI. Simulations are conducted to verify the proposed method. The positioning errors of the proposed method are analysed and discussed. Subaperture testing experiments of a 100-mm aperture flat are performed and compared with full-aperture absolute measurement results. The stitched errors with 0.018 2 PV and 0.003 2 RMS are obtained.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A method of self-calibration for integrated capacitive sensors
    Johnson, PM
    Thiel, DV
    James, D
    Cornelius, M
    SMART STRUCTURES, DEVICES, AND SYSTEMS II, PT 1 AND 2, 2005, 5649 : 486 - 491
  • [42] Stage Cartesian self-calibration: a second method
    Takac, MT
    Whittey, J
    18TH ANNUAL SYMPOSIUM ON PHOTOMASK TECHNOLOGY AND MANAGEMENT, 1998, 3546 : 498 - 504
  • [43] A Self-Calibration Method for Rotational Stereo Vision
    Guo, Beili
    Guan, Qiu
    Chen, S. Y.
    2009 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, VOL III, PROCEEDINGS, 2009, : 128 - 132
  • [44] Measurement data self-calibration fusion method
    Fu H.
    Yang H.
    Wen X.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2019, 34 (08): : 1759 - 1763
  • [45] Self-calibration of hybrid central catadioptric and perspective cameras
    Deng, Xiaoming
    Wu, Fuchao
    Wu, Yihong
    Duan, Fuqing
    Chang, Liang
    Wang, Hongan
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2012, 116 (06) : 715 - 729
  • [46] Testing aspheric surface with annular subaperture stitching method based on Hartmann Shack sensor
    Xu, Hongyan
    Xian, Hao
    Zhang, Yudong
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656
  • [47] Robust subaperture stitching method based on three-dimensional surface data matching
    Li, Lulu
    Liu, Qian
    Huang, Wen
    OPTICAL ENGINEERING, 2019, 58 (03)
  • [48] A WEIGHTED ITERATIVE METHOD FOR ROBUST SELF-CALIBRATION
    Liu Shigang Wu Chengke Tang Li Jia Jing National Key Laboratory of ISN Xidian University Xian China
    JournalofElectronics, 2006, (05) : 713 - 717
  • [49] The self-calibration method of IR mixer with low IF
    Andrzej Szymański
    Ewa Kurjata-Pfitzner
    Jan Lesiński
    Jerzy Wąsowski
    Analog Integrated Circuits and Signal Processing, 2008, 55 : 115 - 124
  • [50] A Process Variation Insensitive Bandgap Reference with Self-Calibration Technique
    Du, Ling
    Ning, Ning
    Wu, Kejun
    Liu, Yang
    Yu, Qi
    2013 IEEE 10TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2013,