Hybrid self-calibration method for reference surface elimination in subaperture stitching interferometry

被引:2
|
作者
Liu, WeiJian [1 ]
Gao, Zhishan [1 ]
Wang, Ruoyan [1 ]
Che, Xiaoyu [1 ]
Wang, Lingjie [2 ]
Lei, Lihua [3 ]
Guo, Zhenyan [1 ]
Yuan, Qun [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Xiao Lingwei Rd 200, Nanjing 210094, Jiangsu, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Key Lab Opt Syst Adv Mfg Technol, Changchun 130033, Peoples R China
[3] Shanghai Key Lab Online Test & Control Technol, Shanghai 201203, Peoples R China
基金
中国国家自然科学基金;
关键词
Subaperture stitching; Wavefront interferometry; Error elimination; LARGE FLAT;
D O I
10.1016/j.optcom.2022.128278
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Subaperture stitching interferometry (SSI) is an essential method for the map testing of large-aperture optical components. The surface map of a reference surface is a typical error source. In this study, we propose a hybrid self-calibration method to eliminate the reference surface error in SSI by combining the modified shift-rotation method and the maximum likelihood method. The traditional shift-rotation method is a general full-aperture absolute interferometric measurement that can retain localized irregularities. The shift-rotation operations are leveraged to generate a couple of subapertures covering the surface under test, whereby a ring of subapertures and a central subaperture are acquired by rotations and a lateral shift, respectively. The modified shift-rotation method is proposed to obtain the rotationally asymmetric components of the test surface in the ring of subapertures. The same components within the central subaperture are retrieved using the maximum likelihood method. Then, the rotationally symmetric components of the test surface are acquired using the least squares method, utilizing the measured data before and after the shift. Reference surface maps are sufficiently eliminated from the measured data. High-frequency components of the test surface are also retained, which engender high-accuracy SSI. Simulations are conducted to verify the proposed method. The positioning errors of the proposed method are analysed and discussed. Subaperture testing experiments of a 100-mm aperture flat are performed and compared with full-aperture absolute measurement results. The stitched errors with 0.018 2 PV and 0.003 2 RMS are obtained.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Self-calibration approach for optical long-baseline interferometry imaging
    Meimon, Serge
    Mugnier, Laurent M.
    Le Besnerais, Guy
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2009, 26 (01) : 108 - 120
  • [32] A self-calibration method for robotic measurement system
    Gong, CH
    Yuan, JX
    Ni, J
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 174 - 181
  • [33] Subaperture stitching wavelength scanning interferometry for 3D surface measurement of complex-shaped optics
    Seo, Yong Bum
    Joo, Ki-Nam
    Ghim, Young-Sik
    Rhee, Hyug-Gyo
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (04)
  • [34] Digital self-calibration method for MEMS sensors
    Colinet, E
    Juillard, J
    Nicu, L
    Bergaud, C
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (04) : 1438 - 1443
  • [35] Self-calibration method for robotic measurement system
    Gong, Chunhe
    Yuan, Jingxia
    Ni, Jun
    American Society of Mechanical Engineers, Manufacturing Engineering Division, MED, 1999, 10 : 879 - 888
  • [36] A Self-Calibration Method of Microbolometer With Vacuum Package
    Liu, Chao
    Fu, Jianyu
    Hou, Ying
    Zhou, Qiong
    Chen, Dapeng
    IEEE SENSORS JOURNAL, 2020, 20 (15) : 8570 - 8575
  • [37] A Self-Calibration Method for an Implantable Displacement Sensor
    Hao, Shiying
    2013 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, COMMUNICATIONS, ANTENNAS AND ELECTRONICS SYSTEMS (IEEE COMCAS 2013), 2013,
  • [38] A linear method for camera pair self-calibration
    Melanitis, Nikos
    Maragos, Petros
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2021, 210
  • [39] The self-calibration method of IR mixer with low IF
    Szymanski, Andrzej
    Kurjata-Pfitzner, Ewa
    Lesinski, Jan
    Wasowski, Jerzy
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2008, 55 (02) : 115 - 124
  • [40] A WEIGHTED ITERATIVE METHOD FOR ROBUST SELF-CALIBRATION
    Liu Shigang Wu Chengke Tang Li Jia Jing (National Key Laboratory of ISN
    Journal of Electronics(China), 2006, (05) : 713 - 717