Modulation of the plasma uniformity by coil and dielectric window structures in an inductively coupled plasma

被引:5
|
作者
Sun, Xiaoyan [1 ]
Zhang, Yuru [2 ]
Ye, Jing [3 ]
Wang, Younian [2 ]
He, Jianxin [1 ]
机构
[1] Zhongyuan Univ Technol, Text & Garment Ind Res Inst, Zhengzhou 450007, Peoples R China
[2] Dalian Univ Technol, Sch Phys, Minist Educ, Key Lab Mat Modificat Laser Ion & Electron Beams, Dalian 116024, Peoples R China
[3] Zhongyuan Univ Technol, Sch Text, Zhengzhou 450007, Peoples R China
基金
中国国家自然科学基金;
关键词
fluid simulation; gradient coil; vertical coil; stepped dielectric window; plasma uniformity; ETCH;
D O I
10.1088/2058-6272/ac0c6b
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The effects of coil and dielectric window structures on the plasma distribution are examined in a cylindrically symmetric planar inductively coupled plasma (ICP). A two-dimensional (2D) fluid model is employed to investigate the design issues of ICP source for etching. When the gradient coil structure is applied at 400 W and 20 mTorr, the ionization rate caused by the power deposition decreases at the reactor center as compared to that in a reactor with a planar coil above the planar dielectric window, and a rather uniform plasma is obtained. However, for the vertical coil geometry, all the coils move to the position of the outermost coil, and the peaks of the power deposition and ionization rate appear at the radial edge of the substrate. In this case, the plasma density is characterized by an edge-high profile. Further, it is observed that the plasma uniformity is improved by increasing the source power under a gas pressure of 20 mTorr and becomes better when the gas pressure increases to 30 mTorr with the source power being fixed at 400 W in the gradient coil configuration, but the uniformity of plasma worsens with the rising source power or pressure due to the strong localization in the vertical coil geometry. Moreover, when the discharge is sustained in a reactor with a stepped dielectric window at r = 0.135 m, the best plasma uniformity is obtained at 400 W and 20 mTorr because the ionization rate is enhanced at the outermost coil, and the dielectric window at r = 0.135 m blocks the diffusion of plasma towards the axis. In addition, higher source power and lower gas pressure produce more uniform plasma for the designs with a stepped window near the symmetry axis. When the dielectric window is stepped at r = 0.135 m, the non-uniformity of plasma initially decreases and then increases with the increase in source power or gas pressure. When the dielectric window is stepped at the radial edge of the chamber, the plasma uniformity is improved by increasing the source power and gas pressure due to the enhanced ionization at the larger radius caused by the severe localization.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] DECAY OF AN INDUCTIVELY COUPLED ARGON PLASMA ABOVE THE LOAD-COIL
    HUANG, M
    LIU, KL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (02) : 153 - 156
  • [42] ANALYTE EXCITATION IN THE INDUCTIVELY COUPLED PLASMA STUDIED BY POWER MODULATION
    OLESIK, JW
    BRADLEY, KR
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) : 377 - 392
  • [43] A Simulation Study on Large-Area Inductively Coupled Plasma for Uniformity Optimization
    Son, Eui-Jeong
    Cho, Sung-Hwan
    Lee, Ho-Jun
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (05) : 2259 - 2266
  • [44] A Simulation Study on Large-Area Inductively Coupled Plasma for Uniformity Optimization
    Eui-Jeong Son
    Sung-Hwan Cho
    Ho-Jun Lee
    Journal of Electrical Engineering & Technology, 2020, 15 : 2259 - 2266
  • [45] High-Uniformity Inductively Coupled Plasma Source With Magnetic Multicusp Confinement
    Biloiu, Costel
    Olson, J. C.
    Scheuer, J. T.
    Renau, A.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (11) : 2456 - 2457
  • [46] Uniformity studies of inductively coupled plasma etching in fabrication of HgCdTe detector arrays
    Bommena, R.
    Velicu, S.
    Boieriu, P.
    Lee, T. S.
    Grein, C. H.
    Tedjojuwono, K. K.
    INFRARED TECHNOLOGY AND APPLICATIONS XXXIII, 2007, 6542
  • [47] Optical computer aided tomography measurements of plasma uniformity in an inductively coupled discharge
    Benck, EC
    Roberts, JR
    CHARACTERIZATION AND METROLOGY FOR ULSI TECHNOLOGY, 1998, 449 : 431 - 435
  • [48] The experimental research on uniformity of argon inductively coupled plasma at different cylinder heights
    Wang, Songbai
    Zhang, Xianhui
    Wang, Hongzhe
    Liu, Linying
    Zhou, Renwu
    Yang, Size
    Liu, Dongping
    APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 686 - +
  • [49] Reduced electron temperature in a magnetized inductively-coupled plasma with internal coil
    Monreal, J. Arancibia
    Chabert, P.
    Godyak, V.
    PHYSICS OF PLASMAS, 2013, 20 (10)
  • [50] Correlation between Coil Configurations and Discharge Characteristics of a Magnetized Inductively Coupled Plasma
    Cheong, Hee-Woon
    JOURNAL OF MAGNETICS, 2016, 21 (02) : 222 - 228