Monte Carlo simulations of the dosimetric characteristics of a new multileaf collimator

被引:0
|
作者
Tacke, M
Szymanowski, H
Schulze, C
Nuss, S
Wehrwein, E
Leidenberger, S
Oelfke, U
机构
[1] German Canc Res Ctr, D-6900 Heidelberg, Germany
[2] Siemens Med Solut, Heidelberg, Germany
关键词
D O I
10.1118/1.1998023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of the work was to investigate the dosimetric characteristics of a new multileaf collimator (160MLC™, Siemens) with the help of Monte Carlo (MC) simulations during the design phase. Method and Materials: The MLC was implemented in the MC code Geant4. For the simulation of the 6 MV treatment beam an experimentally validated phase space and a virtual source model were used. For the simulation of the geometry in Geant4 the jaws and the two leaf packages were implemented with the help of CAD data. First, transmission values for different tungsten sinters were extracted using the simulation codes Geant4 and BEAMnrc and compared to experimental measurements. In a second step, high resolution simulations were performed to detect the leakage at depth of maximum dose. The 20%–80% penumbra along the leaf travel direction was determined for different 10×10 cm2 fields shifted along the x‐axis. The simulated results were compared with measured data obtained with a prototype. Results: The simulation of the transmission values for different tungsten sinters showed a good agreement with the experimental measurements (within 2.0%). This gave an accurate estimation of the absorption coefficient for various leaf materials. Simulations with varying source sizes showed that the leakage and the penumbra depended very much on this parameter: e.g. source sizes of 2 mm and 4 mm result in the interleaf leakages below 0.3% and 0.75% respectively. The results for the leakage and the penumbra are in good agreement with the measurements. Conclusion: This study showed that Geant4 is appropriate for the investigation of the dosimetric characteristics of a multileaf collimator. In particular we could quantify the leakage and the penumbra and evaluate the influence of the beam parameters such as the virtual source size. Conflict of Interest: Research supported by Siemens Oncology Care Systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2018 / 2018
页数:1
相关论文
共 50 条
  • [41] A novel 2D binary collimator for IMRT dose delivery: dosimetric characterization using Monte Carlo simulations
    Altenstein, G.
    Nill, S.
    Heller, J.
    Heid, O.
    Oelfke, U.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (19): : N345 - N364
  • [42] A Comprehensive Geant4 Monte Carlo Model of Multileaf Collimator for Varian TrueBeam Linac
    Kandlakunta, P.
    Zhang, T.
    Mutic, S.
    Khan, R.
    MEDICAL PHYSICS, 2017, 44 (06) : 2909 - 2909
  • [43] Qualitative analysis of irregular fields delivered with dual electron multileaf collimator: A Monte Carlo study
    Inyang, Samuel Okon
    Chamberlain, Alan
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2016, 22 (01) : 5 - 9
  • [44] Assesing multileaf collimator effect on the build-up region using Monte Carlo method
    Zarza Moreno, M.
    Teixeira, N.
    Jesus, A. P.
    Mora, G.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (03): : 163 - 182
  • [45] Design of Diagnostic Multileaf Collimator Based On the Monte Carlo Simulation for Dose Reduction of Diagnostic Radiography
    Han, S.
    Ji, Y.
    Kim, K.
    Choi, S.
    Jung, H.
    Park, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3405 - 3405
  • [46] Characterizing a Geant4 Monte Carlo model of a multileaf collimator for a TrueBeam™ linear accelerator
    Kandlakunta, Praneeth
    Momin, Shadab
    Sloop, Austin
    Zhang, Tiezhi
    Khan, Rao
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 1 - 12
  • [47] Dosimetric comparison of multileaf and fixed cone collimator plans with cyberknife
    Abakay, C. Demiroz
    Kiray, Z.
    Cetintas, S.
    Kurt, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1770 - S1771
  • [48] Physical characteristics of a miniature multileaf collimator
    Xia, P
    Geis, P
    Xing, L
    Ma, C
    Findley, D
    Forster, K
    Boyer, A
    MEDICAL PHYSICS, 1999, 26 (01) : 65 - 70
  • [49] Dosimetric Aspects in the Transmission Factor Determination of a Multileaf Collimator (MLC)
    Gonzalez, G. Resendiz
    Pastenes, M. Perez
    Medina, E. Figueroa
    MEDICAL PHYSICS, 2008, 35 (06)
  • [50] Dosimetric performance of the new high-definition multileaf collimator for intracranial stereotactic radiosurgery
    Dhabaan, Anees
    Elder, Eric
    Schreibmann, Eduard
    Crocker, Ian
    Curran, Walter J.
    Oyesiku, Nelson M.
    Shu, Hui-Kuo
    Fox, Tim
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (03): : 197 - 211