Monte Carlo simulations of the dosimetric characteristics of a new multileaf collimator

被引:0
|
作者
Tacke, M
Szymanowski, H
Schulze, C
Nuss, S
Wehrwein, E
Leidenberger, S
Oelfke, U
机构
[1] German Canc Res Ctr, D-6900 Heidelberg, Germany
[2] Siemens Med Solut, Heidelberg, Germany
关键词
D O I
10.1118/1.1998023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of the work was to investigate the dosimetric characteristics of a new multileaf collimator (160MLC™, Siemens) with the help of Monte Carlo (MC) simulations during the design phase. Method and Materials: The MLC was implemented in the MC code Geant4. For the simulation of the 6 MV treatment beam an experimentally validated phase space and a virtual source model were used. For the simulation of the geometry in Geant4 the jaws and the two leaf packages were implemented with the help of CAD data. First, transmission values for different tungsten sinters were extracted using the simulation codes Geant4 and BEAMnrc and compared to experimental measurements. In a second step, high resolution simulations were performed to detect the leakage at depth of maximum dose. The 20%–80% penumbra along the leaf travel direction was determined for different 10×10 cm2 fields shifted along the x‐axis. The simulated results were compared with measured data obtained with a prototype. Results: The simulation of the transmission values for different tungsten sinters showed a good agreement with the experimental measurements (within 2.0%). This gave an accurate estimation of the absorption coefficient for various leaf materials. Simulations with varying source sizes showed that the leakage and the penumbra depended very much on this parameter: e.g. source sizes of 2 mm and 4 mm result in the interleaf leakages below 0.3% and 0.75% respectively. The results for the leakage and the penumbra are in good agreement with the measurements. Conclusion: This study showed that Geant4 is appropriate for the investigation of the dosimetric characteristics of a multileaf collimator. In particular we could quantify the leakage and the penumbra and evaluate the influence of the beam parameters such as the virtual source size. Conflict of Interest: Research supported by Siemens Oncology Care Systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2018 / 2018
页数:1
相关论文
共 50 条
  • [31] Dosimetric comparison of MapCheck with Monte Carlo simulations
    Luo, W.
    Yin, F.
    Ma, C.
    Fan, J.
    Song, H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2440 - 2440
  • [32] Dosimetric comparison of an integrated multileaf-collimator versus a conventional collimator
    Georg, D
    Julia, F
    Briot, E
    Huyskens, D
    Wolff, U
    Dutreix, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11): : 2285 - 2303
  • [33] Monte Carlo Modeling of Modulated Electron Beams Delivered Through a Photon Multileaf Collimator
    Tynan, P.
    Stathakis, S.
    Esquivel, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [34] Calculations of a millennium multileaf collimator using the DPM and BEAM/DOSXYZ Monte Carlo codes
    Tyagi, N
    Chetty, I
    Fraass, B
    Bielajew, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1230 - 1230
  • [35] A method for determining dosimetric leaf separation of a multileaf collimator
    Kulmala, A.
    Rintala, A.
    Pennanen, J.
    Tenhunen, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S749 - S750
  • [36] Implementation of Monte Carlo Dose Calculation for a Multileaf Collimator Equipped Robotic Radiotherapy System
    Li, J. S.
    Fan, J.
    Ma, C-M
    MEDICAL PHYSICS, 2015, 42 (06) : 3442 - 3442
  • [37] 6 MV dosimetric characterization of the 160 MLC™, the new Siemens multileaf collimator
    Tacke, Martin B.
    Nill, Simeon
    Haring, Peter
    Oelfke, Uwe
    MEDICAL PHYSICS, 2008, 35 (05) : 1634 - 1642
  • [38] Dosimetric study of grid therapy using a multileaf collimator
    Ha, J
    Zhang, G
    Naqvi, S
    Regine, W
    Yu, C
    MEDICAL PHYSICS, 2005, 32 (06) : 2021 - 2021
  • [39] Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study
    Molazadeh, Mikaeil
    Zeinali, Ahad
    Robatjazi, Mostafa
    Shirazi, Alireza
    Geraily, Ghazale
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 113 - 124
  • [40] Monte Carlo simulations and dosimetric studies of an irradiation facility
    Belchior, A.
    Botelho, M. L.
    Vaz, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 70 - 72