A thin, flexible multielectrode grid for high-density surface EMG

被引:129
|
作者
Lapatki, BG
van Dijk, JP
Jonas, IE
Zwarts, MJ
Stegeman, DF
机构
[1] Univ Freiburg, Sch Dent Med, Dept Orthodont, D-79106 Freiburg, Germany
[2] Univ Med Ctr Nijmegen, Inst Neurol, Dept Clin Neurophysiol, NL-6500 HB Nijmegen, Netherlands
[3] Interuniv Inst Fundamental & Clin Human Movement, NL-1081 BT Amsterdam, Netherlands
关键词
electrode array; single motor unit analysis; multichannel EMG; electromyography; facial muscles;
D O I
10.1152/japplphysiol.00521.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Although the value of high-density surface electromyography (sEMG) has already been proven in fundamental research and for specific diagnostic questions, there is as yet no broad clinical application. This is partly due to limitations of construction principles and application techniques of conventional electrode array systems. We developed a thin, highly flexible, two-dimensional multielectrode sEMG grid, which is manufactured by using flexprint techniques. The material used as electrode carrier (Polyimid, 50 mum thick) allows grids to be cut out in any required shape or size. One universal grid version can therefore be used for many applications, thereby reducing costs. The reusable electrode grid is attached to the skin by using specially prepared double-sided adhesive tape, which allows the selective application of conductive cream only directly below the detection surfaces. To explore the practical possibilities, this technique was applied in single motor unit analysis of the facial musculature. The high mechanical flexibility allowed the electrode grid to follow the skin surface even in areas with very uneven contours, resulting in good electrical connections in the whole recording area. The silver-chloride surfaces of the electrodes and their low electrode-to-skin impedances guaranteed high baseline stability and a low signal noise level. The electrode- to-skin attachment proved to withstand saliva and great tensile forces due to mimic contractions. The inexpensive, universally adaptable and minimally obstructive sensor allows the principal advantages of high-density sEMG to be extended to all skeletal muscles accessible from the skin surface and may lay the foundation for more broad clinical application of this noninvasive, two-dimensional sEMG technique.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 50 条
  • [41] Unsupervised Spike Sorting for Large-Scale, High-Density Multielectrode Arrays
    Hilgen, Gerrit
    Sorbaro, Martino
    Pirmoradian, Sahar
    Muthmann, Jens-Oliver
    Kepiro, Ibolya Edit
    Ullo, Simona
    Ramirez, Cesar Juarez
    Encinas, Albert Puente
    Maccione, Alessandro
    Berdondini, Luca
    Murino, Vittorio
    Sona, Diego
    Zanacchi, Francesca Cella
    Sernagor, Evelyne
    Hennig, Matthias Helge
    CELL REPORTS, 2017, 18 (10): : 2521 - 2532
  • [42] Identification of Motor Unit Discharge Patterns from High-Density Surface EMG during High Contraction Levels
    Holobar, A.
    Minetto, M. A.
    Botter, A.
    Farina, D.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 1165 - +
  • [43] Compression of high-density EMG signals for trapezius and gastrocnemius muscles
    Cinthia Itiki
    Sergio S Furuie
    Roberto Merletti
    BioMedical Engineering OnLine, 13
  • [44] THIN METALLIC FILMS FOR HIGH-DENSITY
    BATE, G
    IEEE TRANSACTIONS ON MAGNETICS, 1965, MAG1 (03) : 193 - &
  • [45] Compression of high-density EMG signals for trapezius and gastrocnemius muscles
    Itiki, Cinthia
    Furuie, Sergio S.
    Merletti, Roberto
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [46] Introduction to EMG for the Study of Movement: From Bipolar to High-Density
    Soedirdjo, S. D. H.
    Afsharipour, B.
    Cattarello, P.
    Merletti, R.
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION II, VOLS 1 AND 2, 2017, 15 : 117 - 121
  • [47] HIGH-DENSITY MICRO FLEXIBLE DISK DRIVES
    ADACHI, O
    SUGITA, K
    YANO, N
    REVIEW OF THE ELECTRICAL COMMUNICATIONS LABORATORIES, 1987, 35 (03): : 247 - 251
  • [48] A FLEXIBLE REDUNDANCY TECHNIQUE FOR HIGH-DENSITY DRAMS
    HORIGUCHI, M
    ETOH, J
    AOKI, M
    ITOH, K
    MATSUMOTO, T
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1991, 26 (01) : 12 - 17
  • [49] MOTOR UNIT PROPERTIES OF BICEPS BRACHII IN CHRONIC STROKE PATIENTS ASSESSED WITH HIGH-DENSITY SURFACE EMG
    Kallenberg, Laura A. C.
    Hermens, Hermie J.
    MUSCLE & NERVE, 2009, 39 (02) : 177 - 185
  • [50] Topographical characteristics of motor units of the lower facial musculature revealed by means of high-density surface EMG
    Lapatki, BG
    Oostenveld, R
    Van Dijk, JP
    Jonas, IE
    Zwarts, MJ
    Stegeman, DF
    JOURNAL OF NEUROPHYSIOLOGY, 2006, 95 (01) : 342 - 354