A thin, flexible multielectrode grid for high-density surface EMG

被引:129
|
作者
Lapatki, BG
van Dijk, JP
Jonas, IE
Zwarts, MJ
Stegeman, DF
机构
[1] Univ Freiburg, Sch Dent Med, Dept Orthodont, D-79106 Freiburg, Germany
[2] Univ Med Ctr Nijmegen, Inst Neurol, Dept Clin Neurophysiol, NL-6500 HB Nijmegen, Netherlands
[3] Interuniv Inst Fundamental & Clin Human Movement, NL-1081 BT Amsterdam, Netherlands
关键词
electrode array; single motor unit analysis; multichannel EMG; electromyography; facial muscles;
D O I
10.1152/japplphysiol.00521.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Although the value of high-density surface electromyography (sEMG) has already been proven in fundamental research and for specific diagnostic questions, there is as yet no broad clinical application. This is partly due to limitations of construction principles and application techniques of conventional electrode array systems. We developed a thin, highly flexible, two-dimensional multielectrode sEMG grid, which is manufactured by using flexprint techniques. The material used as electrode carrier (Polyimid, 50 mum thick) allows grids to be cut out in any required shape or size. One universal grid version can therefore be used for many applications, thereby reducing costs. The reusable electrode grid is attached to the skin by using specially prepared double-sided adhesive tape, which allows the selective application of conductive cream only directly below the detection surfaces. To explore the practical possibilities, this technique was applied in single motor unit analysis of the facial musculature. The high mechanical flexibility allowed the electrode grid to follow the skin surface even in areas with very uneven contours, resulting in good electrical connections in the whole recording area. The silver-chloride surfaces of the electrodes and their low electrode-to-skin impedances guaranteed high baseline stability and a low signal noise level. The electrode- to-skin attachment proved to withstand saliva and great tensile forces due to mimic contractions. The inexpensive, universally adaptable and minimally obstructive sensor allows the principal advantages of high-density sEMG to be extended to all skeletal muscles accessible from the skin surface and may lay the foundation for more broad clinical application of this noninvasive, two-dimensional sEMG technique.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 50 条
  • [31] HIGH-DENSITY SURFACE EMG BIOFEEDBACK FROM THE TRAPEZIUS FOR REAL-TIME POSTURAL CORRECTION
    Gaffney, Brecca M.
    Maluf, Katrina S.
    Davidson, Bradley S.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [32] Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
    Del Vecchio, A.
    Holobar, A.
    Falla, D.
    Felici, F.
    Enoka, R. M.
    Farina, D.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2020, 53
  • [33] Functional mapping of the pelvic floor and sphincter muscles from high-density surface EMG recordings
    Yun Peng
    Jinbao He
    Rose Khavari
    Timothy B. Boone
    Yingchun Zhang
    International Urogynecology Journal, 2016, 27 : 1689 - 1696
  • [34] Fasciculations and their F-response revisited: High-density surface EMG in ALS and benign fasciculations
    Kleine, Bert U.
    Boekestein, Werner A.
    Arts, Ilse M. P.
    Zwarts, Machiel J.
    Schelhaas, H. Jurgen
    Stegeman, Dick F.
    CLINICAL NEUROPHYSIOLOGY, 2012, 123 (02) : 399 - 405
  • [35] High-density Surface and Intramuscular EMG Data from the Tibialis Anterior During Dynamic Contractions
    J. Cortney Bradford
    Andrew Tweedell
    Logan Leahy
    Scientific Data, 10
  • [36] Properties of Motor Units of Elbow and Ankle Muscles Decomposed Using High-Density Surface EMG
    Hassan, Altamash S.
    Kim, Edward H.
    Khurram, Obaid U.
    Cummings, Mark
    Thompson, Christopher K.
    McPherson, Laura Miller
    Heckman, C. J.
    Dewald, Julius P. A.
    Negro, Francesco
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3874 - 3878
  • [37] Detecting motor unit abnormalities in amyotrophic lateral sclerosis using high-density surface EMG
    Nishikawa, Yuichi
    Holobar, Ales
    Watanabe, Kohei
    Takahashi, Tetsuya
    Ueno, Hiroki
    Maeda, Noriaki
    Maruyama, Hirofumi
    Tanaka, Shinobu
    Hyngstrom, Allison S.
    CLINICAL NEUROPHYSIOLOGY, 2022, 142 : 262 - 272
  • [38] Surface EMG vs. High-Density EMG: Tradeoff Between Performance and Usability for Head Orientation Prediction in VR Application
    Sugiarto, Tommy
    Hsu, Chun-Lung
    Sun, Chi-Tien
    Hsu, Wei-Chun
    Ye, Shu-Hao
    Lu, Kuan-Ting
    IEEE ACCESS, 2021, 9 : 45418 - 45427
  • [39] Surface oxidation defect detection of high-density flexible integrated circuit substrate
    Hu, Yueming
    Li, Lu
    Luo, Jiaxiang
    Jisuanji Jicheng Zhizao Xitong/Computer Integrated Manufacturing Systems, CIMS, 2020, 26 (09): : 2379 - 2387
  • [40] Hardware considerations of a spatial filter for decorrelating high-density multielectrode neural recordings
    Thomson, Kyle E.
    Oweiss, Karim G.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 5364 - +