Rapid and selective determination of UV filters in seawater by liquid chromatography-tandem mass spectrometry combined with stir bar sorptive extraction

被引:65
|
作者
Nguyen, Kieu T. N. [1 ]
Scapolla, Carlo [1 ]
Di Carro, Marina [1 ]
Magi, Emanuele [1 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, I-16146 Genoa, Italy
关键词
Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Electrospray; Atmospheric pressure chemical ionization; Stir bar sorptive extraction-liquid desorption (SBSE-LD); UV filters; Seawater; PRESSURE CHEMICAL-IONIZATION; ELECTROSPRAY-IONIZATION; WATER SAMPLES; MICROEXTRACTION; OPTIMIZATION; BIOCIDES; SLUDGE; MS;
D O I
10.1016/j.talanta.2011.07.085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fast liquid chromatography coupled to triple-quadrupole tandem mass spectrometry was employed for the determination of six UV filters in seawater. The separation of the analytes was achieved in less than 5 min; polarity switching was used as four of the analytes were ionized in positive mode and the remaining two in negative mode. Two ionization sources were employed and compared: atmospheric pressure chemical ionization (APCI) gave better results than electrospray ionization (ESI) for all analytes, with higher reproducibility and lower detection limits. Therefore APCI was chosen for the determination of the analytes in seawater samples using stir bar sorptive extraction-liquid desorption (SBSE-LD). Quantitative analysis was performed in multiple reaction monitoring (MRM) mode; fragmentation pathways of the analytes with regard to the formation of the MRM ions were also proposed. For the analysis of seawater samples, calibration curves were drawn using SBSE in spiked seawater. All figures of merit of the method were satisfactory; limits of detection were particularly low for the four analytes ionized in positive mode, being in the range 8-31 ng/L. The method was applied to the determination of the six UV filters in seawater samples from Liguria, Italy. Only benzophenone-3 (BP-3) and ethylhexyl methoxycinnamate (EHMC) were measured in the analyzed samples; some of the remaining analytes were also detected but always below the limit of quantitation. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2375 / 2384
页数:10
相关论文
共 50 条
  • [41] Determination of five booster biocides in seawater by stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry
    Giraldez, I.
    Chaguaceda, E.
    Bujalance, M.
    Morales, E.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1271 : 17 - 26
  • [42] Novel coatings for stir bar sorptive extraction to determine pharmaceuticals and personal care products in environmental waters by liquid chromatography and tandem mass spectrometry
    Gilart, Nuria
    Miralles, Nuria
    Maria Marce, Rosa
    Borrull, Francesc
    Fontanals, Nuria
    ANALYTICA CHIMICA ACTA, 2013, 774 : 51 - 60
  • [43] Continental bottled water assessment by stir bar sorptive extraction followed by gas chromatography-tandem mass spectrometry (SBSE-GC-MS/MS)
    Guart, Albert
    Calabuig, Ignacio
    Lacorte, Silvia
    Borrell, Antonio
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (04) : 2846 - 2855
  • [44] Continental bottled water assessment by stir bar sorptive extraction followed by gas chromatography-tandem mass spectrometry (SBSE-GC-MS/MS)
    Albert Guart
    Ignacio Calabuig
    Silvia Lacorte
    Antonio Borrell
    Environmental Science and Pollution Research, 2014, 21 : 2846 - 2855
  • [45] Determination of Synthetic Musks and UV Filters in Surface Water by Stir Bar Sorption Extraction and Gas Chromatography-Mass Spectrometry
    Tong L.
    Pan M.
    Yang Z.-P.
    Tian Q.
    Song S.-L.
    Journal of Chinese Mass Spectrometry Society, 2019, 40 (03) : 233 - 243
  • [46] Determination of Polycyclic Aromatic Hydrocarbons in Air by Stir Bar Sorptive Extraction-Thermal Desorption-Gas Chromatography Tandem Mass Spectrometry
    Li Xiao-Min
    Zhang Qing-Hua
    Wang Pu
    Li Ying-Ming
    Jiang Gui-Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (11) : 1641 - 1646
  • [47] Determination of polycyclic aromatic hydrocarbons in air by stir bar sorptive extraction-thermal desorption-gas chromatography tandem mass spectrometry
    Li X.-M.
    Zhang Q.-H.
    Wang P.
    Li Y.-M.
    Jiang G.-B.
    Fenxi Huaxue/ Chinese Journal of Analytical Chemistry, 2011, 39 (11): : 1641 - 1646
  • [48] Use of experimental design in the investigation of stir bar sorptive extraction followed by ultra-high-performance liquid chromatography-tandem mass spectrometry for the analysis of explosives in water samples
    Schramm, Sebastien
    Vailhen, Dominique
    Bridoux, Maxime Cyril
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1433 : 24 - 33
  • [49] Development of monolith-based stir bar sorptive extraction and liquid chromatography tandem mass spectrometry method for sensitive determination of ten sulfonamides in pork and chicken samples
    Xiaojia Huang
    Linli Chen
    Dongxing Yuan
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6885 - 6889
  • [50] Development of monolith-based stir bar sorptive extraction and liquid chromatography tandem mass spectrometry method for sensitive determination of ten sulfonamides in pork and chicken samples
    Huang, Xiaojia
    Chen, Linli
    Yuan, Dongxing
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (21) : 6885 - 6889