Rapid and selective determination of UV filters in seawater by liquid chromatography-tandem mass spectrometry combined with stir bar sorptive extraction
被引:65
|
作者:
Nguyen, Kieu T. N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Genoa, Dept Chem & Ind Chem, I-16146 Genoa, ItalyUniv Genoa, Dept Chem & Ind Chem, I-16146 Genoa, Italy
Nguyen, Kieu T. N.
[1
]
Scapolla, Carlo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Genoa, Dept Chem & Ind Chem, I-16146 Genoa, ItalyUniv Genoa, Dept Chem & Ind Chem, I-16146 Genoa, Italy
Scapolla, Carlo
[1
]
Di Carro, Marina
论文数: 0引用数: 0
h-index: 0
机构:
Univ Genoa, Dept Chem & Ind Chem, I-16146 Genoa, ItalyUniv Genoa, Dept Chem & Ind Chem, I-16146 Genoa, Italy
Di Carro, Marina
[1
]
Magi, Emanuele
论文数: 0引用数: 0
h-index: 0
机构:
Univ Genoa, Dept Chem & Ind Chem, I-16146 Genoa, ItalyUniv Genoa, Dept Chem & Ind Chem, I-16146 Genoa, Italy
Liquid chromatography-tandem mass spectrometry (LC-MS/MS);
Electrospray;
Atmospheric pressure chemical ionization;
Stir bar sorptive extraction-liquid desorption (SBSE-LD);
UV filters;
Seawater;
PRESSURE CHEMICAL-IONIZATION;
ELECTROSPRAY-IONIZATION;
WATER SAMPLES;
MICROEXTRACTION;
OPTIMIZATION;
BIOCIDES;
SLUDGE;
MS;
D O I:
10.1016/j.talanta.2011.07.085
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Fast liquid chromatography coupled to triple-quadrupole tandem mass spectrometry was employed for the determination of six UV filters in seawater. The separation of the analytes was achieved in less than 5 min; polarity switching was used as four of the analytes were ionized in positive mode and the remaining two in negative mode. Two ionization sources were employed and compared: atmospheric pressure chemical ionization (APCI) gave better results than electrospray ionization (ESI) for all analytes, with higher reproducibility and lower detection limits. Therefore APCI was chosen for the determination of the analytes in seawater samples using stir bar sorptive extraction-liquid desorption (SBSE-LD). Quantitative analysis was performed in multiple reaction monitoring (MRM) mode; fragmentation pathways of the analytes with regard to the formation of the MRM ions were also proposed. For the analysis of seawater samples, calibration curves were drawn using SBSE in spiked seawater. All figures of merit of the method were satisfactory; limits of detection were particularly low for the four analytes ionized in positive mode, being in the range 8-31 ng/L. The method was applied to the determination of the six UV filters in seawater samples from Liguria, Italy. Only benzophenone-3 (BP-3) and ethylhexyl methoxycinnamate (EHMC) were measured in the analyzed samples; some of the remaining analytes were also detected but always below the limit of quantitation. (C) 2011 Elsevier B.V. All rights reserved.
机构:
Water Res Inst, Slovak Natl Water Reference Lab, Nabrezie arm gen L Svobodu 5, Bratislava 81249, Slovakia
Slovak Univ Technol Bratislava, Inst Analyt Chem, Fac Chem & Food Technol, Radlinskeho 9, Bratislava 812 37, SlovakiaWater Res Inst, Slovak Natl Water Reference Lab, Nabrezie arm gen L Svobodu 5, Bratislava 81249, Slovakia
Nagyova, Slavka
Tolgyessy, Peter
论文数: 0引用数: 0
h-index: 0
机构:
Water Res Inst, Slovak Natl Water Reference Lab, Nabrezie arm gen L Svobodu 5, Bratislava 81249, SlovakiaWater Res Inst, Slovak Natl Water Reference Lab, Nabrezie arm gen L Svobodu 5, Bratislava 81249, Slovakia
Tolgyessy, Peter
Hrouzkova, Svetlana
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Inst Analyt Chem, Fac Chem & Food Technol, Radlinskeho 9, Bratislava 812 37, SlovakiaWater Res Inst, Slovak Natl Water Reference Lab, Nabrezie arm gen L Svobodu 5, Bratislava 81249, Slovakia
机构:
China Agr Univ, Coll Vet Med, Beijing 100193, Peoples R ChinaChina Agr Univ, Coll Vet Med, Beijing 100193, Peoples R China
Wang, Ze Ping
Shen, Jian Zhong
论文数: 0引用数: 0
h-index: 0
机构:
China Agr Univ, Coll Vet Med, Beijing 100193, Peoples R ChinaChina Agr Univ, Coll Vet Med, Beijing 100193, Peoples R China
Shen, Jian Zhong
Linhardt, Robert J.
论文数: 0引用数: 0
h-index: 0
机构:
Rensselaer Polytech Inst, Ctr Biotechnol & Interdisiplinary Studies, Troy, NY 12180 USAChina Agr Univ, Coll Vet Med, Beijing 100193, Peoples R China
Linhardt, Robert J.
Jiang, Hui
论文数: 0引用数: 0
h-index: 0
机构:
China Agr Univ, Coll Vet Med, Beijing 100193, Peoples R ChinaChina Agr Univ, Coll Vet Med, Beijing 100193, Peoples R China
Jiang, Hui
Cheng, Lin Li
论文数: 0引用数: 0
h-index: 0
机构:
China Agr Univ, Coll Vet Med, Beijing 100193, Peoples R China
Rensselaer Polytech Inst, Ctr Biotechnol & Interdisiplinary Studies, Troy, NY 12180 USAChina Agr Univ, Coll Vet Med, Beijing 100193, Peoples R China
Cheng, Lin Li
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,
2017,
1046
: 98
-
101