Posterior osteosynthesis with monoaxial lateral mass screw-rod system for unstable C1 burst fractures

被引:31
|
作者
Zhang, Yin-shun [1 ]
Zhang, Jian-xiang [1 ]
Yang, Qing-guo [1 ]
Li, Wei [1 ]
Tao, Hui [1 ]
Shen, Cai-liang [1 ]
机构
[1] Anhui Med Univ, Dept Orthopaed, Affiliated Hosp 1, 218 Jixi Rd, Hefei 230022, Anhui, Peoples R China
来源
SPINE JOURNAL | 2018年 / 18卷 / 01期
关键词
Atlas fractures; C1; fractures; Jefferson fractures; Open reduction and internal fixation (ORIF); Osteosynthesis; Transverse atlantal ligament; JEFFERSON FRACTURES; ATLAS FRACTURES; BIOMECHANICAL ANALYSIS; PRESERVING REDUCTION; FIXATION; LIGAMENT; CLASSIFICATION; CONSTRUCT;
D O I
10.1016/j.spinee.2017.06.029
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Surgical treatment for unstable atlas fractures has evolved in recent decades from C1-C2 or C0-C2 fusion to motion-preservation techniques of open reduction and internal fixation (ORIF). However, regardless of a transoral or a posterior approach, the reduction is still not satisfactory. PURPOSE: The article describes and evaluates a new technique for treating unstable atlas fractures by using a monoaxial screw-rod system. STUDY DESIGN: This is a retrospective study. PATIENT SAMPLE: The sample includes adult patients with unstable C1 fractures treated with a posterior monoaxial screw-rod system. OUTCOME MEASURES: The outcome measures included a visual analog pain scale, radiographic reduction (lateral mass displacement [LMD]), maintenance of reduction, C1-C2 instability (anterior atlantodens interval), and complications. MATERIALS AND METHODS: From August 2013 to May 2016, nine consecutive patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with posterior ORIF by using a monoaxial screw-rod system. The medical records and the preoperative and postoperative radiographs were reviewed. Preoperative and postoperative computed tomography scans were used to specify the fracture types and to assess the reduction. RESULTS: All nine patients with a mean age of 50.3 years successfully underwent surgery with this technique, and a follow-up of 17.4 +/- 9.3 months was performed. Transverse atlantal ligament (TAL) injury was found in eight of the nine patients: one of type I and seven of type II. The preoperative LMD averaged 7.0 +/- 2.2 mm and was restored completely after surgery; all the fractures achieved bony healing without loss of reduction or implant failure. None of the patients had complications of neurologic deficit, vertebral artery injury, or wound infection associated with the surgical procedure. Two patients complained of greater occipital nerve neuralgia after the operation, which gradually disappeared in 1 month. All patients had a well-preserved range of motion of the upper cervical spine at the final follow-up. CONCLUSIONS: Posterior osteosynthesis with a monoaxial screw-rod system is capable of an almost anatomical reduction for the unstable atlas fractures. The TAL incompetence may not be a contraindication to ORIF for C1 fractures, but the long-term effect of C1-C2 instability remains to be further investigated. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [41] Freehand C1 lateral mass screw fixation technique: our experience
    Simsek, Serkan
    Yigitkanli, Kazim
    Seckin, Hakan
    Akyol, Cetin
    Belen, Deniz
    Bavbek, Murad
    SURGICAL NEUROLOGY, 2009, 72 (06): : 676 - 681
  • [42] CT evaluation of occipitocervical joint violation by C1 lateral mass screw
    Yang, Jun-Song
    Chen, Hao
    Yan, Liang
    Liu, Peng
    Liu, Tuan-Jiang
    Huang, Da-Geng
    Hao, Ding-Jun
    SPINE JOURNAL, 2019, 19 (11): : 1902 - 1902
  • [43] Biomechanical comparison of the pullout strengths of C1 lateral mass screws and C1 posterior arch screws
    Zarro, Christopher M.
    Ludwig, Steven C.
    Hsieh, Adam H.
    Seal, Charles N.
    Gelb, Daniel E.
    SPINE JOURNAL, 2013, 13 (12): : 1892 - 1896
  • [44] Posterior Atalntoaxial Fusion with C1 Lateral Mass Screw and C2 Pedicle Screw Supplemented with Miniplate Fixation for Interlaminar Fusion: A Preliminary Report
    Yoon, Sang-Mok
    Baek, Jin-Wook
    Kim, Dae-Hyun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 52 (02) : 120 - 125
  • [45] Posterior C1-C2 screw-rod fixation and autograft fusion for the treatment of os odontoideum with C1-C2 instability
    Huang, Da-Geng
    Wang, Tao
    Hao, Ding-Jun
    He, Bao-Rong
    Liu, Tuan-Jiang
    Ma, Xiao-Wen
    Yu, Cheng-Cheng
    Feng, Hang
    Zhao, Song-Chum
    Hui, Hua
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 163 : 71 - 75
  • [46] Iliac screw for reconstructing posterior pelvic ring in Tile type C1 pelvic fractures
    Li, Yonggang
    Sang, Xiguang
    Wang, Zhiyong
    Cheng, Lin
    Liu, Hao
    Qin, Tao
    Di, Kai
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (06) : 923 - 928
  • [47] C2 Nerve Dysfunction Associated with C1 Lateral Mass Screw Fixation
    Huang, Da-geng
    Hao, Ding-jun
    Li, Guang-lin
    Guo, Hao
    Zhang, Yu-chen
    He, Bao-rong
    ORTHOPAEDIC SURGERY, 2014, 6 (04) : 269 - 273
  • [48] Endovascular Treatment of Vertebral Artery Injury during Cervical Posterior Fusion (C1 Lateral Mass Screw) A Case Report
    Yoon, Kyeong-Wook
    Ko, Jung-Ho
    Cho, Chun-Sung
    Lee, Sang-Koo
    Kim, Young-Joon
    Kim, Young Jin
    INTERVENTIONAL NEURORADIOLOGY, 2013, 19 (03) : 370 - 376
  • [49] Aberrant posterior inferior cerebellar artery injury with C1 lateral mass screw placement: a case report and review of the literature
    Nassr, Ahmad N.
    Swann, Presley P.
    Huston, John, III
    Abdelfatah, Mohamed M.
    Rose, Peter S.
    Currier, Bradford L.
    SPINE JOURNAL, 2014, 14 (09): : E7 - E14
  • [50] Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation
    Eck, Jason C.
    Walker, Matt P.
    Currier, Bradord L.
    Chen, Qingshan
    Yaszemski, Michael J.
    An, Kai-Nan
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (07): : 505 - 508