Posterior osteosynthesis with monoaxial lateral mass screw-rod system for unstable C1 burst fractures

被引:31
|
作者
Zhang, Yin-shun [1 ]
Zhang, Jian-xiang [1 ]
Yang, Qing-guo [1 ]
Li, Wei [1 ]
Tao, Hui [1 ]
Shen, Cai-liang [1 ]
机构
[1] Anhui Med Univ, Dept Orthopaed, Affiliated Hosp 1, 218 Jixi Rd, Hefei 230022, Anhui, Peoples R China
来源
SPINE JOURNAL | 2018年 / 18卷 / 01期
关键词
Atlas fractures; C1; fractures; Jefferson fractures; Open reduction and internal fixation (ORIF); Osteosynthesis; Transverse atlantal ligament; JEFFERSON FRACTURES; ATLAS FRACTURES; BIOMECHANICAL ANALYSIS; PRESERVING REDUCTION; FIXATION; LIGAMENT; CLASSIFICATION; CONSTRUCT;
D O I
10.1016/j.spinee.2017.06.029
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Surgical treatment for unstable atlas fractures has evolved in recent decades from C1-C2 or C0-C2 fusion to motion-preservation techniques of open reduction and internal fixation (ORIF). However, regardless of a transoral or a posterior approach, the reduction is still not satisfactory. PURPOSE: The article describes and evaluates a new technique for treating unstable atlas fractures by using a monoaxial screw-rod system. STUDY DESIGN: This is a retrospective study. PATIENT SAMPLE: The sample includes adult patients with unstable C1 fractures treated with a posterior monoaxial screw-rod system. OUTCOME MEASURES: The outcome measures included a visual analog pain scale, radiographic reduction (lateral mass displacement [LMD]), maintenance of reduction, C1-C2 instability (anterior atlantodens interval), and complications. MATERIALS AND METHODS: From August 2013 to May 2016, nine consecutive patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with posterior ORIF by using a monoaxial screw-rod system. The medical records and the preoperative and postoperative radiographs were reviewed. Preoperative and postoperative computed tomography scans were used to specify the fracture types and to assess the reduction. RESULTS: All nine patients with a mean age of 50.3 years successfully underwent surgery with this technique, and a follow-up of 17.4 +/- 9.3 months was performed. Transverse atlantal ligament (TAL) injury was found in eight of the nine patients: one of type I and seven of type II. The preoperative LMD averaged 7.0 +/- 2.2 mm and was restored completely after surgery; all the fractures achieved bony healing without loss of reduction or implant failure. None of the patients had complications of neurologic deficit, vertebral artery injury, or wound infection associated with the surgical procedure. Two patients complained of greater occipital nerve neuralgia after the operation, which gradually disappeared in 1 month. All patients had a well-preserved range of motion of the upper cervical spine at the final follow-up. CONCLUSIONS: Posterior osteosynthesis with a monoaxial screw-rod system is capable of an almost anatomical reduction for the unstable atlas fractures. The TAL incompetence may not be a contraindication to ORIF for C1 fractures, but the long-term effect of C1-C2 instability remains to be further investigated. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [21] Atlantoaxial Stabilization by Posterior C1 and C2 Screw-Rod Fixation for Various Pathologies: Case Series and Comprehensive Review of Literature
    Unni, Chandramohan
    Pettakkandy, Vijayan
    Jaleel, Abdul P.
    Soren, Subrat Kumar
    Vineeth, K. K.
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2021, 12 (02) : 228 - 235
  • [22] Lateral Mass Screw Fixation of the Atlas: Importance of Anatomy of C1 for Lateral Mass Screw Placement
    Sonntag, Volker K. H.
    WORLD NEUROSURGERY, 2010, 74 (2-3) : 270 - 271
  • [23] Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability
    Xie, Yang
    Li, Zhonghai
    Tang, Hao
    Li, Ming
    Guan, Zhengmao
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (12) : 1592 - 1594
  • [24] C1 lateral mass screw placement via the posterior arch: a technique comparison and anatomic analysis
    Lin, James M.
    Hipp, John A.
    Reitman, Charles A.
    SPINE JOURNAL, 2013, 13 (11): : 1549 - 1555
  • [25] C1 Titanium Cables Combined with C2 Pedicle Screw-Rod Fixation for Atlantoaxial Instability Not Suitable for Placement of C1 Screws
    Zhang, Jie-Hong
    Zhang, Zhi-Jing
    Zhu, Ya
    Shi, Jian-Dong
    Li, Bin
    Lu, Yi-Sheng
    WORLD NEUROSURGERY, 2018, 120 : E453 - E456
  • [26] Posterior atiantal lateral mass fixation technique with polyaxial screw and rod fixation system
    Calisaneller, Tarkan
    Yilmaz, Cem
    Ozdemir, Ozgur
    Caner, Hakan
    TURKISH NEUROSURGERY, 2008, 18 (02) : 142 - 148
  • [27] C1 anatomy and dimensions relative to lateral mass screw placement
    Christensen, David M.
    Eastlack, Robert K.
    Lynch, James J.
    Yaszemski, Michael J.
    Currier, Bradford L.
    SPINE, 2007, 32 (08) : 844 - 848
  • [28] Atlas (C1) lateral mass screw placement using the intersection between lateral mass and inferomedial edge of the posterior arch: a cadaveric study
    Liawrungrueang, Wongthawat
    Riew, K. Daniel
    Sugandhavesa, Nantawit
    Bunmaprasert, Torphong
    EUROPEAN SPINE JOURNAL, 2022, 31 (12) : 3443 - 3451
  • [29] Atlas (C1) lateral mass screw placement using the intersection between lateral mass and inferomedial edge of the posterior arch: a cadaveric study
    Wongthawat Liawrungrueang
    K. Daniel Riew
    Nantawit Sugandhavesa
    Torphong Bunmaprasert
    European Spine Journal, 2022, 31 : 3443 - 3451
  • [30] An Anatomical and Radiological Study for C1 Lateral Mass Screw Fixation
    Akay, Ali
    Ruksen, Mete
    Cagli, M. Sedat
    Kitis, Omer
    Erturk, Mete
    Zileli, Mehmet
    JOURNAL OF NEUROLOGICAL SCIENCES-TURKISH, 2013, 30 (02): : 328 - 336