Performances of a heat exchanger and pilot boiler for the development of a condensing gas boiler

被引:46
|
作者
Lee, Seungro [1 ]
Kum, Sung-Min [2 ]
Lee, Chang-Eon [1 ]
机构
[1] Inha Univ, Dept Mech Engn, Inchon 402751, South Korea
[2] Halla Univ, Sch Mech & Automot Engn, Wonju 220712, South Korea
关键词
Condensing boiler; Heat exchanger; Pilot boiler; NO(x) and CO emissions; HELICAL BAFFLES; FLAMES;
D O I
10.1016/j.energy.2011.05.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this research, design factors for a heat exchanger and boiler were investigated using a simplified model of a heat exchanger and pilot condensing boiler, respectively. Specifications of each heat exchanger component (e.g., upper heat exchanger (UHE) and lower heat exchanger (LHE): coil heat exchanger (CHE); baffles) were investigated using a model apparatus, and the comprehensive performance of the pilot gas boiler was examined experimentally. The heating efficiency of the boiler developed was about 90% when using the optimal designed heat exchangers. Compared to a conventional Bunsen-type boiler, the heating efficiency was improved about 10%. Additionally, NO(x), and CO emissions were about 30 ppm and 160 ppm, respectively, based on a 0% O(2) basis at an equivalence ratio of 0.70, which is an appropriate operating condition. However, the pollutant emission of the boiler developed is satisfactory considering the emission performance of a condensing boiler, even though CO emission must be reduced. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3945 / 3951
页数:7
相关论文
共 50 条
  • [31] Erosion durability of steels in steam boiler heat exchanger tubes
    Meuronen, V
    WEAR, 2000, 240 (1-2) : 164 - 167
  • [32] Numerical prediction of high efficiency boiler heat exchanger performance
    Huang, LY
    Wen, JX
    Karayiannis, TG
    Matthews, RD
    APPLIED THERMAL ENGINEERING, 1998, 18 (11) : 1089 - 1099
  • [33] DETECTION AND LOCALIZATION OF FAILURES IN A BOILER-HEAT EXCHANGER SYSTEM
    CECCHIN, T
    SAUTER, D
    SIBILLE, P
    EVRARD, JM
    REVUE GENERALE DE THERMIQUE, 1991, 30 (349): : 24 - 30
  • [34] MILP optimization of energy supply by using a boiler, a condensing turbine and a heat pump
    Bojic, M
    Dragicevic, S
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (04) : 591 - 608
  • [35] New configurations of a heat recovery absorption heat pump integrated with a natural gas boiler for boiler efficiency improvement
    Qu, Ming
    Abdelaziz, Omar
    Yin, Hongxi
    ENERGY CONVERSION AND MANAGEMENT, 2014, 87 : 175 - 184
  • [36] Heat exchanger simulation and recovery device design of waste heat boiler of gas turbine generator set on ocean platform
    Duan, Aixia
    Zhihuang, Yong
    Duan, Yanling
    Wang, Qiuhong
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2020, 38 (02) : 1257 - 1263
  • [37] Demonstration of a Martian surface power system sodium boiler heat exchanger
    Schuller, Michael
    Kurwitz, Cable
    Williams, Rube
    Best, Frederick
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM STAIF 2008, 2008, 969 : 415 - +
  • [38] Reduction of large noise generated in boiler and heat exchanger by flexible walls
    1837, Japan Society of Mechanical Engineers (79):
  • [39] COOPERATIVE DEVELOPMENT AND MANUFACTURE OF A GAS HEATING BOILER
    MEULENBRUG, GC
    LINN, W
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1986, 94 (08): : M193 - M194
  • [40] Corrosion failure analysis of the heat exchanger in a hot water heating boiler
    Liu, Shijie
    Wu, Haomin
    Zhao, Qinxin
    Liang, Zhiyuan
    ENGINEERING FAILURE ANALYSIS, 2022, 142