Corrosion failure analysis of the heat exchanger in a hot water heating boiler

被引:9
|
作者
Liu, Shijie [1 ]
Wu, Haomin [1 ]
Zhao, Qinxin [1 ]
Liang, Zhiyuan [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermal Fluid Sci & Engn MOE, Xian 710049, Peoples R China
关键词
Corrosion; 20G steel; Failure analysis; Water quality; Electrochemical; STRESS-CORROSION; WALL TUBE; CRACKING;
D O I
10.1016/j.engfailanal.2022.106847
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The corrosion failure of the heat-exchanger made of 20G steel in a hot water heating boiler was investigated. The morphology and phase compositions of the corrosion products were analyzed using X-ray diffraction (XRD), scanning electron microscope (SEM) with energy disperse spec-troscopy (EDS). The results showed that the boiler feed water did not meet the water quality standard, which contained excessive ion concentrations of Ca and Mg and dissolved oxygen content. At the surface of failed tubes, loose corrosive products containing numerous cracks provided micro-channels for Cl- diffusion into the matrix of 20G steel, thus leading to the local electrochemical reaction. This continuous and Cl-induced electrochemical erosion at some posi-tions led to a vicious cycle which caused more severe damage to the tube, finally resulting in a perforation failure of the tube. To avoid this kind of accident happening, some suggestions are given in this paper.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Corrosion failure analysis for heat exchanger
    Jing, Hongyang
    Shang, Jin
    Xu, Lianyong
    Han, Yongdian
    Hanjie Xuebao/Transactions of the China Welding Institution, 2016, 37 (09): : 1 - 4
  • [2] Corrosion Failure Analysis on Heat Exchanger Pipes
    Qiankun Z.
    Yafei S.
    Sixian R.
    Huifeng L.
    Xingjiang Z.
    Journal of Failure Analysis and Prevention, 2017, 17 (2) : 349 - 353
  • [3] Corrosion failure of titanium tubes of a heat exchanger for the heating of dissolving lye
    Romanovski, Valentin
    Hedberg, Yolanda S.
    Paspelau, Andrei
    Frantskevich, Vitali
    Noel, James J.
    Romanovskaia, Elena
    ENGINEERING FAILURE ANALYSIS, 2021, 129
  • [4] Hot corrosion resistance of NiCr based Cermet coatings for the protection of boiler heat exchanger tubes
    Ding, ZX
    Pei, ZL
    Zhan, WB
    Wang, Q
    CONTRIBUTIONS OF SURFACE ENGINEERING TO MODERN MANUFACTURING AND REMANUFACTURING, 2002, : 188 - 192
  • [5] Analysis of a load-side heat exchanger for a solar domestic hot water heating system
    Smith, TR
    Burns, PJ
    HIttle, DC
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04): : 270 - 274
  • [6] Hot corrosion Type II of FeCr-based model alloys for boiler and heat exchanger applications
    Koenig, Till
    Montero, Xabier
    Galetz, Mathias C.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2019, 70 (08): : 1371 - 1384
  • [7] Horizontal Shower Heat Exchanger as an Effective Domestic Hot Water Heating Alternative
    Kordana-Obuch, Sabina
    Starzec, Mariusz
    ENERGIES, 2022, 15 (13)
  • [8] The corrosion failure analysis of plate pipe for plate heat exchanger
    Song Wen-ming
    Yang Gui-rong
    Hao Yuan
    Zhang Yu-fu
    ADVANCED ENGINEERING MATERIALS III, PTS 1-3, 2013, 750-752 : 2252 - +
  • [9] Corrosion Failure Analysis of Flow Plate in Plate Heat Exchanger
    Song, Min Ji
    Choi, Gahyun
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Heesan
    Kim, Jung-Gu
    Lee, Soo Yeol
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2021, 20 (04): : 204 - 209
  • [10] Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler
    Kim, Youngsu
    Chae, Hobyung
    Hong, Minki
    Song, Min Ji
    Cho, Jeongmin
    Kim, Woo Cheol
    Ha, Tae Baek
    Lee, Soo Yeol
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2019, 18 (02): : 55 - 60