Feasibility of Using a Factory-Calibrated Continuous Glucose Monitoring System to Diagnose Type 2 Diabetes

被引:2
|
作者
Frank, Spencer [1 ,2 ]
Hames, Kazanna C. [1 ]
Jbaily, Abdulrahman [1 ]
Park, Jee Hye [1 ]
Stroyeck, Chuck [1 ]
Price, David [1 ]
机构
[1] Dexcom Inc, R&D Dept, San Diego, CA USA
[2] Dexcom Inc, 6340 Sequence Dr, San Diego, CA 92121 USA
关键词
Continuous glucose monitoring; Type; 2; diabetes; Glucose variability; Diagnostic tests; TOLERANCE TEST; GLYCEMIC VARIABILITY; REPRODUCIBILITY; QUALITY; HBA(1C);
D O I
10.1089/dia.2022.0189
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context: Plasma glucose or A1C criteria can be used to establish the diagnosis of type 2 diabetes (T2D).Objective: We examined whether continuous glucose monitoring (CGM) data from a single 10-day wear period could form the basis of an alternative diagnostic test for T2D.Design: We developed a binary classification diagnostic CGM (dCGM) algorithm using a dataset of 716 individual CGM sensor sessions from 563 participants with associated A1C measurements from seven clinical trials. Data from 470 participants were used for training and 93 participants for testing (49 normoglycemic [A1C <5.7%], 27 prediabetes, and 17 T2D [A1C >= 6.5%] not using pharmacotherapy). dCGM performance was evaluated against the accompanying A1C measurement, which was assumed to provide the correct diagnosis.Results: The dCGM algorithm's overall sensitivity, specificity, positive predictive value, and negative predictive value were 71%, 93%, 71%, and 93%, respectively. At other clinically relevant A1C thresholds, dCGM specificity among normoglycemic participants was 98% (48/49 correctly classified), and for participants with suboptimally controlled diabetes (A1C >= 7%, above the American Diabetes Association recommended A1C goal) the sensitivity was 100% (8/8 participants correctly diagnosed with T2D).Conclusions: Classifications based on the dCGM algorithm were in good agreement with traditional methods based on A1C. The dCGM algorithm may provide an alternative method for screening and diagnosing T2D, and warrants further investigation.
引用
收藏
页码:907 / 914
页数:8
相关论文
共 50 条
  • [41] Feasibility of Continuous Glucose Monitoring in Infants and Toddlers with Type 1 Diabetes
    Tsalikian, Eva
    Fox, Larry
    Weinzimer, Stuart
    Buckingham, Bruce
    White, Neil
    Beck, Roy
    Xing, Dongyuan
    Ruedy, Katrina
    Kollman, Craig
    DIABETES, 2011, 60 : A335 - A335
  • [42] Continuous glucose monitoring in persons with type 2 diabetes not using insulin
    Cowart, Kevin
    Updike, Wendy H.
    Franks, Rachel
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (11) : 1049 - 1055
  • [43] A New Era in Continuous Glucose Monitoring: Food and Drug Administration Creates a New Category of Factory-Calibrated Nonadjunctive, Interoperable Class II Medical Devices
    Garg, Satish K.
    Akturk, H. Kaan
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (06) : 391 - 394
  • [44] Analysis of "Accuracy of a 14-Day Factory Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes"
    Kompala, Tejaswi
    Neinstein, Aaron B.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (01): : 78 - 80
  • [45] Continuous Glucose Monitoring in Patients With Type 2 Diabetes
    Beck, R. W.
    Riddlesworth, T. D.
    Ruedy, K.
    Ahmann, A.
    Haller, S.
    Kruger, D.
    McGill, J. B.
    Polonsky, W.
    Price, D.
    Aronoff, S.
    Aronson, R.
    Toschi, E.
    Kollman, C.
    Bergenstal, R.
    ANNALS OF INTERNAL MEDICINE, 2017, 167 (06) : I20 - I20
  • [46] Accuracy of continuous glucose monitoring system during exercise in type 2 diabetes
    Figueira, Franciele R.
    Umpierre, Daniel
    Ribeiro, Jorge P.
    Tetelbom, Pedro S.
    Henn, Nicoli T.
    Esteves, Jorge F.
    Schaan, Beatriz D.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2012, 98 (03) : E36 - E39
  • [47] Feasibility and acceptability of continuous glucose monitoring and accelerometer technology in exercising individuals with type 2 diabetes
    Allen, Nancy A.
    Jacelon, Cynthia S.
    Chipkin, Stuart R.
    JOURNAL OF CLINICAL NURSING, 2009, 18 (03) : 373 - 383
  • [48] Feasibility and Acceptability of Intermittently Scanned Continuous Glucose Monitoring for Women with Type 2 Diabetes in Pregnancy
    McLean, Anna
    Sinha, Ashim
    Barr, Elizabeth
    Maple-Brown, Louise
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 256 - 258
  • [50] Continuous Glucose Monitoring in Non-Insulin-Using Individuals with Type 2 Diabetes: Acceptability, Feasibility, and Teaching Opportunities
    Allen, Nancy A.
    Fain, James A.
    Braun, Barry
    Chipkin, Stuart R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (03) : 151 - 158