Feasibility of Using a Factory-Calibrated Continuous Glucose Monitoring System to Diagnose Type 2 Diabetes

被引:2
|
作者
Frank, Spencer [1 ,2 ]
Hames, Kazanna C. [1 ]
Jbaily, Abdulrahman [1 ]
Park, Jee Hye [1 ]
Stroyeck, Chuck [1 ]
Price, David [1 ]
机构
[1] Dexcom Inc, R&D Dept, San Diego, CA USA
[2] Dexcom Inc, 6340 Sequence Dr, San Diego, CA 92121 USA
关键词
Continuous glucose monitoring; Type; 2; diabetes; Glucose variability; Diagnostic tests; TOLERANCE TEST; GLYCEMIC VARIABILITY; REPRODUCIBILITY; QUALITY; HBA(1C);
D O I
10.1089/dia.2022.0189
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context: Plasma glucose or A1C criteria can be used to establish the diagnosis of type 2 diabetes (T2D).Objective: We examined whether continuous glucose monitoring (CGM) data from a single 10-day wear period could form the basis of an alternative diagnostic test for T2D.Design: We developed a binary classification diagnostic CGM (dCGM) algorithm using a dataset of 716 individual CGM sensor sessions from 563 participants with associated A1C measurements from seven clinical trials. Data from 470 participants were used for training and 93 participants for testing (49 normoglycemic [A1C <5.7%], 27 prediabetes, and 17 T2D [A1C >= 6.5%] not using pharmacotherapy). dCGM performance was evaluated against the accompanying A1C measurement, which was assumed to provide the correct diagnosis.Results: The dCGM algorithm's overall sensitivity, specificity, positive predictive value, and negative predictive value were 71%, 93%, 71%, and 93%, respectively. At other clinically relevant A1C thresholds, dCGM specificity among normoglycemic participants was 98% (48/49 correctly classified), and for participants with suboptimally controlled diabetes (A1C >= 7%, above the American Diabetes Association recommended A1C goal) the sensitivity was 100% (8/8 participants correctly diagnosed with T2D).Conclusions: Classifications based on the dCGM algorithm were in good agreement with traditional methods based on A1C. The dCGM algorithm may provide an alternative method for screening and diagnosing T2D, and warrants further investigation.
引用
收藏
页码:907 / 914
页数:8
相关论文
共 50 条
  • [31] Modeling the error of factory-calibrated continuous glucose monitoring sensors: application to Dexcom G6 sensor data
    Vettoretti, Martina
    Del Favero, Simone
    Sparacino, Giovanni
    Facchinetti, Andrea
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 750 - 753
  • [32] FEASIBILITY AND ACCEPTABILITY OF CONTINUOUS GLUCOSE MONITORING IN YOUTH WITH TYPE 2 DIABETES
    Patel, Tejal
    Estrada, Doris Elizabeth
    Chung, Stephanie
    HORMONE RESEARCH IN PAEDIATRICS, 2024, 97 : 244 - 245
  • [33] Continuous Glucose Monitoring in Youth with Type 2 Diabetes: A Pilot and Feasibility Study
    Chesser, Hannah
    Srinivasan, Shylaja
    Wong, Jenise C.
    DIABETES, 2021, 70
  • [34] A continuous glucose monitoring in type 2 diabetes
    Pavlicek, Vojtech
    DIABETOLOGE, 2017, 13 (07): : 522 - 524
  • [35] Continuous glucose monitoring in type 2 diabetes
    Harman-Boehm, Ilana
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2008, 82 : S118 - S121
  • [36] Impact of factory-calibrated Freestyle Libre System with new glucose algorithm measurement accuracy and clinical performance in children with type 1 diabetes during summer camp
    Szadkowska, Agnieszka
    Michalak, Arkadiusz
    Losiewicz, Aleksandra
    Kusmierczyk, Hanna
    Krawczyk-Rusiecka, Kinga
    Chrzanowski, Jedrzej
    Gawrecki, Andrzej
    Zozulinska-Ziolkiewicz, Dorota
    Fendler, Wojciech
    PEDIATRIC DIABETES, 2021, 22 (02) : 261 - 270
  • [37] The Feasibility of Continuous Glucose Monitoring in Youth with Type 2 Diabetes Mellitus: A Pilot Study
    Laroche, Allison
    Utzschneider, Kristina
    Pihoker, Catherine
    DIABETES, 2019, 68
  • [38] Use of Factory-Calibrated Real-time Continuous Glucose Monitoring Improves Time in Target and HbA1c in a Multiethnic Cohort of Adolescents and Young Adults With Type 1 Diabetes: The MILLENNIALS Study
    Thabit, Hood
    Prabhu, Joshi Navis
    Mubita, Womba
    Fullwood, Catherine
    Azmi, Shazli
    Urwin, Andrea
    Doughty, Ian
    Leelarathna, Lalantha
    DIABETES CARE, 2020, 43 (10) : 2537 - 2543
  • [39] Improved Accuracy of 14-Day Factory-Calibrated FreeStyle Libre System with New Glucose Algorithm
    Karinka, Shridhara Alva
    Bailey, Timothy S.
    Brazg, Ronald L.
    Budiman, Erwin S.
    Castorino, Kristin
    Christiansen, Mark P.
    Liljenquist, David R.
    Liu, Hanqing
    DIABETES, 2019, 68
  • [40] Feasibility of prolonged continuous glucose monitoring in toddlers with type 1 diabetes
    Tsalikian, Eva
    Fox, Larry
    Weinzimer, Stuart
    Buckingham, Bruce
    White, Neilh
    Beck, Roy
    Kollman, Craig
    Xing, Dongyuan
    Ruedy, Katrina
    PEDIATRIC DIABETES, 2012, 13 (04) : 294 - 300