Feasibility of Using a Factory-Calibrated Continuous Glucose Monitoring System to Diagnose Type 2 Diabetes

被引:2
|
作者
Frank, Spencer [1 ,2 ]
Hames, Kazanna C. [1 ]
Jbaily, Abdulrahman [1 ]
Park, Jee Hye [1 ]
Stroyeck, Chuck [1 ]
Price, David [1 ]
机构
[1] Dexcom Inc, R&D Dept, San Diego, CA USA
[2] Dexcom Inc, 6340 Sequence Dr, San Diego, CA 92121 USA
关键词
Continuous glucose monitoring; Type; 2; diabetes; Glucose variability; Diagnostic tests; TOLERANCE TEST; GLYCEMIC VARIABILITY; REPRODUCIBILITY; QUALITY; HBA(1C);
D O I
10.1089/dia.2022.0189
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context: Plasma glucose or A1C criteria can be used to establish the diagnosis of type 2 diabetes (T2D).Objective: We examined whether continuous glucose monitoring (CGM) data from a single 10-day wear period could form the basis of an alternative diagnostic test for T2D.Design: We developed a binary classification diagnostic CGM (dCGM) algorithm using a dataset of 716 individual CGM sensor sessions from 563 participants with associated A1C measurements from seven clinical trials. Data from 470 participants were used for training and 93 participants for testing (49 normoglycemic [A1C <5.7%], 27 prediabetes, and 17 T2D [A1C >= 6.5%] not using pharmacotherapy). dCGM performance was evaluated against the accompanying A1C measurement, which was assumed to provide the correct diagnosis.Results: The dCGM algorithm's overall sensitivity, specificity, positive predictive value, and negative predictive value were 71%, 93%, 71%, and 93%, respectively. At other clinically relevant A1C thresholds, dCGM specificity among normoglycemic participants was 98% (48/49 correctly classified), and for participants with suboptimally controlled diabetes (A1C >= 7%, above the American Diabetes Association recommended A1C goal) the sensitivity was 100% (8/8 participants correctly diagnosed with T2D).Conclusions: Classifications based on the dCGM algorithm were in good agreement with traditional methods based on A1C. The dCGM algorithm may provide an alternative method for screening and diagnosing T2D, and warrants further investigation.
引用
收藏
页码:907 / 914
页数:8
相关论文
共 50 条
  • [1] FEASIBILITY OF USING A FACTORY-CALIBRATED CGM SYSTEM TO DIAGNOSE TYPE 2 DIABETES
    Frank, S.
    Hames, K.
    Jbaily, A.
    Welsh, J.
    Stroyeck, C.
    Price, D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A48 - A48
  • [2] Factory-Calibrated Continuous Glucose Monitoring System Accuracy During Exercise in Adolescents With Type 1 Diabetes Mellitus
    Dyess, Ryan J.
    McKay, Timothy
    Feygin, Yana
    Wintergerst, Kupper
    Thrasher, Bradly J.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (03): : 584 - 591
  • [3] The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
    Bailey, Timothy
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    Alva, Shridhara
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 787 - 794
  • [4] Accuracy of a Factory-Calibrated Continuous Glucose Monitor in Individuals With Diabetes on Hemodialysis
    Villard, Orianne
    Breton, Marc D.
    Rao, Swati
    Voelmle, Mary K.
    Fuller, Morgan R.
    Myers, Helen E.
    McFadden, Ryan K.
    Luke, Zander S.
    Wakeman, Christian A.
    Clancy-Oliveri, Mary
    Basu, Ananda
    Stumpf, Meaghan M.
    DIABETES CARE, 2022, 45 (07) : 1666 - 1669
  • [5] Continuous Glucose Monitoring in Subcutaneous Tissue Using Factory-Calibrated Sensors: A Pilot Study
    Hoss, Udo
    Jeddi, Iman
    Schulz, Mark
    Budiman, Erwin
    Bhogal, Claire
    McGarraugh, Geoffrey
    DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (08) : 591 - 597
  • [6] Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
    Nishimura, Eri
    Oka, Shuntaro
    Ozawa, Junichi
    Tanaka, Kosuke
    Momose, Taichi
    Kabe, Kazuhiko
    Namba, Fumihiko
    TURKISH ARCHIVES OF PEDIATRICS, 2021, 56 (02): : 115 - 120
  • [7] Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
    Aida, Azusa
    Noto, Hiroshi
    AMERICAN JOURNAL OF CASE REPORTS, 2022, 23
  • [8] Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use
    Lundemose, Sissel Banner
    Laugesen, Christian
    Ranjan, Ajenthen Gayathri
    Norgaard, Kirsten
    SENSORS, 2023, 23 (22)
  • [9] Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes
    Alva, Shridhara
    Bailey, Timothy
    Brazg, Ronald
    Budiman, Erwin S.
    Castorino, Kristin
    Christiansen, Mark P.
    Forlenza, Gregory
    Kipnes, Mark
    Liljenquist, David R.
    Liu, Hanqing
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (01): : 70 - 77
  • [10] Consistent Accuracy over 10 Days with a Factory-Calibrated Continuous Glucose Monitoring System in Children and Adults
    Zhang, Xiaohe
    Johnson, Terri
    Price, David A.
    Balo, Andrew
    DIABETES, 2018, 67