Quantitative and rapid detection of C-reactive protein using quantum dot-based lateral flow test strip

被引:71
|
作者
Wu, Ruili [1 ]
Zhou, Shuai [2 ]
Chen, Ting [2 ]
Li, Jinjie [1 ]
Shen, Huaibin [1 ]
Chai, Yujuan [2 ]
Li, Lin Song [1 ]
机构
[1] Henan Univ, Key Lab Special Funct Mat, Minist Educ, Kaifeng 475004, Henan, Peoples R China
[2] NepQD Biotech Corp, Taizhou 225300, Peoples R China
基金
中国国家自然科学基金;
关键词
C-reactive protein; Quantum dots; QD-based lateral flow immunoassays; SENSITIVE DETECTION; IMMUNOCHROMATOGRAPHIC ASSAY; IMMUNOASSAY; LABELS;
D O I
10.1016/j.aca.2017.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel QD-based immunoassay on a paper-based lateral flow system has been developed to quantitatively detect C-reactive protein (CRP). Different standard CRP antigens from 1 to 200 mu g mL(-1) were diluted 200-fold and only 60 mu L diluted sample were needed to load onto the sample pad. The QD fluorescence signals on the test line and the control line were able to be observed within 3 min after the initiation of assay, and the limit of detection was as sensitive as 0.30 ng mL(-1) by measuring the fluorescence intensity immediately afterwards with fluorescence immunoassay analyzer. The linearity on the detection of QD fluorescence signals has been established well in the range of 0.5 ng mL(-1) and 1 mu g mL(-1) for CRP. The precision of the assay has been confirmed for low coefficient of variation (CV), satisfying less than 15% (intra-assay and inter-assay), and the accuracy of assay meets the requirements with the mean recovery of the control was 102.63%. These results indicated that such newly developed platform was reliable with high sensitivity, rapidness, and could cover a broad range of target concentrations. Furthermore, a total of 135 human serum clinical samples with inflammation or infection with the concentration of CRP from 0.2 to 200 mu g mL(-1) has been used to check the performance of this QD-based LFIA, it correlated very well with Roche Tina-quant CRP (Latex) (r = 0.966, n = 135). (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [31] Sensitive and Quantitative Detection of C-Reaction Protein Based on Immunofluorescent Nanospheres Coupled with Lateral Flow Test Strip
    Hu, Jiao
    Zhang, Zhi-Ling
    Wen, Cong-Ying
    Tang, Man
    Wu, Ling-Ling
    Liu, Cui
    Zhu, Lian
    Pang, Dai-Wen
    ANALYTICAL CHEMISTRY, 2016, 88 (12) : 6577 - 6584
  • [32] A quantum dot-based lateral flow immunoassay for the rapid, quantitative, and sensitive detection of specific IgE for mite allergens in sera from patients with allergic rhinitis
    Zheng-Yan Liang
    Yu-Qin Deng
    Ze-Zhang Tao
    Analytical and Bioanalytical Chemistry, 2020, 412 : 1785 - 1794
  • [33] Quantum Dot-Based Aptasensor for Sensitive Protein Detection
    Shin, Seonmi
    Kim, Yea Seul
    Kang, Ho-Jung
    Hah, Sang Soo
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (07): : 2091 - 2093
  • [34] A quantum dot-based lateral flow immunoassay for the rapid, quantitative, and sensitive detection of specific IgE for mite allergens in sera from patients with allergic rhinitis
    Liang, Zheng-Yan
    Deng, Yu-Qin
    Tao, Ze-Zhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (08) : 1785 - 1794
  • [35] Rapid and Quantitative Detection of Prostate Specific Antigen with a Quantum Dot Nanobeads-Based Immunochromatography Test Strip
    Li, Xue
    Li, Wenbin
    Yang, Qiuhua
    Gong, Xiaoqun
    Guo, Weisheng
    Dong, Chunhong
    Liu, Junqing
    Xuan, Lixue
    Chang, Jin
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (09) : 6406 - 6414
  • [36] Sensitive and rapid quantification of C-reactive protein using quantum dot-labeled microplate immunoassay
    Luo, Yang
    Zhang, Bo
    Chen, Ming
    Jiang, Tianlun
    Zhou, Daiyang
    Huang, Junfu
    Fu, Weiling
    JOURNAL OF TRANSLATIONAL MEDICINE, 2012, 10
  • [37] Sensitive and rapid quantification of C-reactive protein using quantum dot-labeled microplate immunoassay
    Yang Luo
    Bo Zhang
    Ming Chen
    Tianlun Jiang
    Daiyang Zhou
    Junfu Huang
    Weiling Fu
    Journal of Translational Medicine, 10
  • [38] Rapid detection of coliform bacteria using a lateral flow test strip assay
    Tominaga, Tatsuya
    JOURNAL OF MICROBIOLOGICAL METHODS, 2019, 160 : 29 - 35
  • [39] A portable fluorescence biosensor for rapid and sensitive glutathione detection by using quantum dots-based lateral flow test strip
    Liu, Juanzu
    Ji, Danyang
    Meng, Hongmin
    Zhang, Lin
    Wang, Junyan
    Huang, Zhongming
    Chen, Juan
    Li, Jianjun
    Li, Zhaohui
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 : 486 - 492
  • [40] Development of a lateral flow immunoassay of C-reactive protein detection based on red fluorescent nanoparticles
    Cai, Yanxue
    Kang, Keren
    Liu, Yujia
    Wang, Yu
    He, Xiaowei
    ANALYTICAL BIOCHEMISTRY, 2018, 556 : 129 - 135