Quantitative and rapid detection of C-reactive protein using quantum dot-based lateral flow test strip

被引:71
|
作者
Wu, Ruili [1 ]
Zhou, Shuai [2 ]
Chen, Ting [2 ]
Li, Jinjie [1 ]
Shen, Huaibin [1 ]
Chai, Yujuan [2 ]
Li, Lin Song [1 ]
机构
[1] Henan Univ, Key Lab Special Funct Mat, Minist Educ, Kaifeng 475004, Henan, Peoples R China
[2] NepQD Biotech Corp, Taizhou 225300, Peoples R China
基金
中国国家自然科学基金;
关键词
C-reactive protein; Quantum dots; QD-based lateral flow immunoassays; SENSITIVE DETECTION; IMMUNOCHROMATOGRAPHIC ASSAY; IMMUNOASSAY; LABELS;
D O I
10.1016/j.aca.2017.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel QD-based immunoassay on a paper-based lateral flow system has been developed to quantitatively detect C-reactive protein (CRP). Different standard CRP antigens from 1 to 200 mu g mL(-1) were diluted 200-fold and only 60 mu L diluted sample were needed to load onto the sample pad. The QD fluorescence signals on the test line and the control line were able to be observed within 3 min after the initiation of assay, and the limit of detection was as sensitive as 0.30 ng mL(-1) by measuring the fluorescence intensity immediately afterwards with fluorescence immunoassay analyzer. The linearity on the detection of QD fluorescence signals has been established well in the range of 0.5 ng mL(-1) and 1 mu g mL(-1) for CRP. The precision of the assay has been confirmed for low coefficient of variation (CV), satisfying less than 15% (intra-assay and inter-assay), and the accuracy of assay meets the requirements with the mean recovery of the control was 102.63%. These results indicated that such newly developed platform was reliable with high sensitivity, rapidness, and could cover a broad range of target concentrations. Furthermore, a total of 135 human serum clinical samples with inflammation or infection with the concentration of CRP from 0.2 to 200 mu g mL(-1) has been used to check the performance of this QD-based LFIA, it correlated very well with Roche Tina-quant CRP (Latex) (r = 0.966, n = 135). (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [21] Dual-Fluorescent Quantum Dot Nanobead-Based Lateral Flow Immunoassay for Simultaneous Detection of C-Reactive Protein and Procalcitonin
    Tang, Xinyue
    Xia, Wenwen
    Han, Huanxing
    Wang, Yucheng
    Wang, Bolong
    Gao, Shouhong
    Zhang, Pengfei
    ACS APPLIED BIO MATERIALS, 2024, 7 (11): : 7659 - 7665
  • [22] Silanized quantum dots as labels in lateral flow test strips for C-reactive protein
    Sobolev, Aleksandr M.
    Byzova, Nadezhda A.
    Goryacheva, Irina Yu
    Zherdev, Anatoly, V
    ANALYTICAL LETTERS, 2019, 52 (12) : 1874 - 1887
  • [23] Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor Based on Quantum Dots and a Lateral Flow Test Strip
    Li, Zhaohui
    Wang, Ying
    Wang, Jun
    Tang, Zhiwen
    Pounds, Joel G.
    Lin, Yuehe
    ANALYTICAL CHEMISTRY, 2010, 82 (16) : 7008 - 7014
  • [24] Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay
    Yanbing Lv
    Ruili Wu
    Kunrui Feng
    Jinjie Li
    Qing Mao
    Hang Yuan
    Huaibin Shen
    Xiangdong Chai
    Lin Song Li
    Journal of Nanobiotechnology, 15
  • [25] Distance-based lateral flow immunoassay for quantitative detection of C-reactive protein in cardiovascular risk assessment
    Ruantip, Sirowan
    Pimpitak, Umaporn
    Puthong, Songchan
    Rengpipat, Sirirat
    Yakoh, Abdulhadee
    Sain, Mohini M.
    Komolpis, Kittinan
    Chaiyo, Sudkate
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 434
  • [26] Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay
    Lv, Yanbing
    Wu, Ruili
    Feng, Kunrui
    Li, Jinjie
    Mao, Qing
    Yuan, Hang
    Shen, Huaibin
    Chai, Xiangdong
    Li, Lin Song
    JOURNAL OF NANOBIOTECHNOLOGY, 2017, 15
  • [27] Evaluation of a rapid bedside test for the quantitative determination of C-reactive protein
    Esposito, S
    Tremolati, E
    Begliatti, E
    Bosis, S
    Gualtieri, L
    Principi, N
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (04) : 438 - 440
  • [28] Dual-Quantum-Dots-Labeled Lateral Flow Strip Rapidly Quantifies Procalcitonin and C-reactive Protein
    XiaoPing Qi
    YunYe Huang
    ZhongShi Lin
    Liang Xu
    Hao Yu
    Nanoscale Research Letters, 2016, 11
  • [29] Dual-Quantum-Dots-Labeled Lateral Flow Strip Rapidly Quantifies Procalcitonin and C-reactive Protein
    Qi, XiaoPing
    Huang, YunYe
    Lin, ZhongShi
    Xu, Liang
    Yu, Hao
    NANOSCALE RESEARCH LETTERS, 2016, 11
  • [30] A pressure-based bioassay for the rapid, portable and quantitative detection of C-reactive protein
    Ji, Tianhai
    Liu, Dan
    Liu, Fang
    Li, Jiuxing
    Ruan, Qingyu
    Song, Yanling
    Tian, Tian
    Zhu, Zhi
    Zhou, Leiji
    Lin, Hui
    Yang, Chaoyong
    Wang, Dong
    CHEMICAL COMMUNICATIONS, 2016, 52 (54) : 8452 - 8454