Development of shielded reflection type pulsed eddy current testing probes for thickness evaluation

被引:2
|
作者
Shin, Young-Kil [1 ]
Choi, Dong-Myung [1 ]
Jang, Kwan-Seob [2 ]
机构
[1] Kunsan Natl Univ, Sch Elect & Informat Engn, Kunsan 573701, Chonbuk, South Korea
[2] Sae An Engn Corp, R&D Inst, Seoul 153803, South Korea
来源
MODERN PHYSICS LETTERS B | 2008年 / 22卷 / 11期
关键词
D O I
10.1142/S0217984908015619
中图分类号
O59 [应用物理学];
学科分类号
摘要
Reflection and send-receive type probe shielded by ferrite is designed to evaluate the thickness of test plate by a pulsed eddy current (PEC) method and effects of pulse width to PEC signal are investigated when a 10.5 mm thick, nonmagnetic plate is inspected. Results show that the best sensitivity to thickness variation can be achieved by the peak value of a PEC signal. Pulse width variation study suggests that the shorter pulse width is desired if the peak value or the zero crossing time is used to evaluate the thickness, while the longer pulse width is needed if the time to peak value is used to evaluate it.
引用
收藏
页码:923 / 928
页数:6
相关论文
共 50 条
  • [21] Comparative evaluation of coil and hall probes in hole detection and thickness measurement on aluminum plates using eddy current testing
    J. Garcia-Martin
    J. Gomez-Gil
    Russian Journal of Nondestructive Testing, 2013, 49 : 482 - 491
  • [22] Pulsed Eddy Current Non-destructive Testing and Evaluation:A Review
    Ali Sophian
    Guiyun Tian
    Mengbao Fan
    Chinese Journal of Mechanical Engineering, 2017, 30 (03) : 500 - 514
  • [23] Pulsed Eddy Current Non-destructive Testing and Evaluation: A Review
    Sophian, Ali
    Tian, Guiyun
    Fan, Mengbao
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2017, 30 (03) : 500 - 514
  • [24] Thickness evaluation of thermal spraying on boiler tubes by eddy current testing
    Takahashi, Yohei
    Urayama, Ryoichi
    Uchimoto, Tetsuya
    Takagi, Toshiyuki
    Naganuma, Hiroshi
    Sugawara, Kazufumi
    Sasaki, Yoriaki
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2012, 39 (1-4) : 419 - 425
  • [25] Evaluation of Pulsed Eddy Current Response and Detection of the Thickness Variation in the Stainless Steel
    Park, D. G.
    Angani, C. S.
    Kim, G. D.
    Kim, C. G.
    Cheong, Y. M.
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (10) : 3893 - 3896
  • [26] Experimental investigation of low-frequency and pulsed eddy current testing in thickness measurement
    Ge, Jiuhao
    Xu, Fei
    Yusa, Noritaka
    NONDESTRUCTIVE TESTING AND EVALUATION, 2024,
  • [27] Analytical modeling for pulsed eddy current testing
    Fan, Meng-Bao
    Huang, Ping-Jie
    Ye, Bo
    Hou, Di-Bo
    Zhang, Guang-Xin
    Zhou, Ze-Kui
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2009, 43 (09): : 1621 - 1624
  • [29] Effects of crack thickness in eddy current testing
    Albanese, R
    Rubinacci, G
    Tamburrino, A
    Villone, F
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (IV), 2000, 17 : 25 - 31
  • [30] Erratum to: Pulsed Eddy Current Non-destructive Testing and Evaluation: A Review
    Ali Sophian
    Guiyun Tian
    Mengbao Fan
    Chinese Journal of Mechanical Engineering, 2017, 30 : 1474 - 1474