Purpose. To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. Methods. A total of 301 eyes from 301 consecutive subjects were enrolled prospectively. Two experienced operators measured each eye three times consecutively with the IOLMaster 700. The axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), and white-to-white (WTW) distance were recorded. Intraoperator repeatability and interoperator reproducibility of the IOLMaster 700 were analyzed using the test-retest (TRT), coefficients of variation (CoV), and intraclass correlation coefficients (ICCs). The agreement between the two devices was evaluated using the Bland-Altman method. Results. The repeatability and reproducibility of the SS-OCT optical biometer were high for all ocular biometry parameters in all groups, except for the WTW in cataract patients (TRT, 0.27-0.44 mm; ICC, 0.86-0.95). The reproducibility of averaged measurements from three consecutive readings (TRT : AL = 0.02 mm, CCT = 5.41 mu m, ACD = 0.03 mm, LT = 0.03 mm, Km = 0.17 D, and WTW = 0.22 mm) was higher than the reproducibility of single measurements (TRT : AL = 0.04 mm, CCT = 7.43 mu m, ACD = 0.06 mm, LT = 0.05 mm, Km = 0.26 D, and WTW = 0.35 mm) in the three groups. The consistency in the data between the two biometers was high, with narrow 95% LoAs in the three groups. Conclusion. Repeatability and reproducibility of the new SS-OCT optical biometer were excellent and consistent with that of the standard biometer with respect to healthy children, healthy adults, and cataract patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Repeatability and Agreement of a Swept-Source Optical Coherence Tomography-Based Biometer IOLMaster 700 Versus a Scheimpflug Imaging-Based Biometer AL-Scan in Cataract Patients
    Chan, Tommy C. Y.
    Wan, Kelvin H.
    Tang, Fang Yao
    Wang, Yu Meng
    Yu, Marco
    Cheung, Carol
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (01): : 35 - 45
  • [42] Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
    Tommy C. Y. Chan
    Marco C. Y. Yu
    Vivian Chiu
    Gilda Lai
    Christopher K. S. Leung
    Poemen P. M. Chan
    Scientific Reports, 11
  • [43] Role of swept-source anterior segment optical coherence tomography in imaging pediatric cataract
    Bhardwaj, Anand
    Kaur, Savleen
    Sukhija, Jaspreet
    Gupta, Parul Chawla
    Ram, Jagat
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (05) : 2132 - 2138
  • [44] Novel perspectives on swept-source optical coherence tomography
    Lavinsky F.
    Lavinsky D.
    International Journal of Retina and Vitreous, 2 (1)
  • [45] Comparison of axial length using a new swept-source optical coherence tomography-based biometer - ARGOS with partial coherence interferometry- based biometer -IOLMaster among school children
    Hussaindeen, Jameel Rizwana
    Mariam, Ephrame G.
    Arunachalam, Sushil
    Bhavatharini, Ramakrishnan
    Gopalakrishnan, Aparna
    Narayanan, Anuradha
    Agarkar, Sumita
    Sivaraman, Viswanathan
    PLOS ONE, 2018, 13 (12):
  • [46] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06): : 802 - 814
  • [47] Widefield Swept-Source Optical Coherence Tomography Angiography
    Shahidzadeh, Anoush
    Kim, Alice Yon
    Aziz, Hassan A.
    Durbin, Mary K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [48] Swept-Source Optical Coherence Tomography Angiography Findings in Adults with a History of Prematurity
    Knapp, Austen
    Chen, Cindy
    Baynes, Kimberly
    Burton, Danielle
    Kaiser, Peter K.
    Srivastava, Sunil K.
    Rachitskaya, Aleksandra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [49] Scleral, Choroidal and Retinal Thickness in Healthy Chinese Children Measured by Swept-source Optical Coherence Tomography
    He, Xiangui
    Deng, Junjie
    Jin, Jiali
    Lv, Minzhi
    Zhu, Jianfeng
    Zou, Haidong
    Xu, Xun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [50] Evaluation of a new dynamic real-time visualization 25 kHz swept-source optical coherence tomography based biometer
    Yu, Jinjin
    Lin, Xuanqiao
    Huang, Xiaomin
    Xu, Zhenyu
    Ning, Rui
    Li, Kexin
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    EYE AND VISION, 2024, 11 (01)