Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients

被引:18
|
作者
Huang, Jinhai [1 ,2 ,3 ]
Zhao, Yuyu [1 ,2 ]
Savini, Giacomo [4 ]
Yu, Guanshun [1 ,2 ]
Yu, Jinjin [1 ,2 ]
Chen, Zhongxing [1 ,2 ]
Tu, Ruixue [1 ,2 ,3 ]
Zhao, Yune [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Eye Hosp, Wenzhou, Zhejiang, Peoples R China
[3] Minist Hlth China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] GB Bietti Fdn IRCCS, Rome, Italy
关键词
INTRAOCULAR-LENS POWER; CALCULATION FORMULAS; MYOPIC PROGRESSION; AXIAL LENGTH; REPEATABILITY; AGREEMENT; ACCURACY; ANTERIOR; REPRODUCIBILITY; PARAMETERS;
D O I
10.1155/2020/8946364
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. Methods. A total of 301 eyes from 301 consecutive subjects were enrolled prospectively. Two experienced operators measured each eye three times consecutively with the IOLMaster 700. The axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), and white-to-white (WTW) distance were recorded. Intraoperator repeatability and interoperator reproducibility of the IOLMaster 700 were analyzed using the test-retest (TRT), coefficients of variation (CoV), and intraclass correlation coefficients (ICCs). The agreement between the two devices was evaluated using the Bland-Altman method. Results. The repeatability and reproducibility of the SS-OCT optical biometer were high for all ocular biometry parameters in all groups, except for the WTW in cataract patients (TRT, 0.27-0.44 mm; ICC, 0.86-0.95). The reproducibility of averaged measurements from three consecutive readings (TRT : AL = 0.02 mm, CCT = 5.41 mu m, ACD = 0.03 mm, LT = 0.03 mm, Km = 0.17 D, and WTW = 0.22 mm) was higher than the reproducibility of single measurements (TRT : AL = 0.04 mm, CCT = 7.43 mu m, ACD = 0.06 mm, LT = 0.05 mm, Km = 0.26 D, and WTW = 0.35 mm) in the three groups. The consistency in the data between the two biometers was high, with narrow 95% LoAs in the three groups. Conclusion. Repeatability and reproducibility of the new SS-OCT optical biometer were excellent and consistent with that of the standard biometer with respect to healthy children, healthy adults, and cataract patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography
    He, Wenwen
    Zhu, Xiangjia
    Wolff, Don
    Zhao, Zhennan
    Sun, Xinghuai
    Lu, Yi
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [22] Comparison of Clinical Outcomes between Swept-source Optical Coherence Tomography Biometer and Partial Coherence Interferometer
    Jang, Mirinae
    Lee, Hye Jin
    Lee, Sang-Yoon
    Kim, Jin Young
    Ma, Dae Joong
    Jeong, Jin Ho
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (08): : 905 - 910
  • [23] Repeatability and reproducibility of a new fully automatic measurement optical low coherence reflectometry biometer and agreement with swept-source optical coherence tomography-based biometer
    Yu, Jinjin
    Zhao, Guoli
    Lei, Chak Seng
    Wan, Ting
    Ning, Rui
    Xing, Wenqian
    Ma, Xindi
    Pan, Hongxian
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (05) : 673 - 678
  • [24] Refractive surprise after cataract surgery secondary to smeared optics of swept-source optical coherence tomography biometer: a case report
    Francis Carr
    Vinod Gangwani
    BMC Ophthalmology, 20
  • [25] The Precision of a New Anterior Segment Optical Coherence Tomographer and Its Comparison With a Swept-Source OCT-Based Optical Biometer in Patients With Cataract
    Wang, Qinmei
    Chen, Min
    Ning, Rui
    Savini, Giacomo
    Wang, Yiran
    Zhang, Tianjiao
    Lin, Xuanqiao
    Chen, Xin
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (09) : 616 - +
  • [26] Refractive surprise after cataract surgery secondary to smeared optics of swept-source optical coherence tomography biometer: a case report
    Carr, Francis
    Gangwani, Vinod
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [27] Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
    Higashiyama, Tomoaki
    Iwasa, Maki
    Ohji, Masahito
    PLOS ONE, 2017, 12 (08):
  • [28] Accuracy of a New Swept-Source Optical Coherence Tomography Biometer for IOL Power Calculation and Comparison to IOL Master
    Savini, Giacomo
    Hoffer, Kenneth J.
    Shammas, H. John
    Aramberri, Jaime
    Huang, Jinhai
    Barboni, Piero
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (10) : 690 - 695
  • [29] Clinical Evaluation of a New Swept-Source Optical Coherence Biometer That Uses Individual Refractive Indices to Measure Axial Length in Cataract Patients
    Tamaoki, Akeno
    Kojima, Takashi
    Hasegawa, Asato
    Yamamoto, Mana
    Kaga, Tatsushi
    Tanaka, Kiyoshi
    Ichikawa, Kazuo
    OPHTHALMIC RESEARCH, 2019, 62 (01) : 11 - 23
  • [30] Normal and Cataract Crystalline Lens Evaluation with Swept-Source Optical Coherence Tomography
    De Castro, Alberto
    Benito, Antonio
    Manzanera, Silvestre
    Mompean, Juan
    Canizares, Belen
    Maria Marin, Jose
    Grulkowski, Ireneusz
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)