Chemically selective polymer substrate based direct isotope dilution alpha spectrometry of Pu

被引:19
|
作者
Paul, Sumana [1 ]
Pandey, Ashok K. [2 ]
Shah, R. V. [1 ]
Aggarwal, S. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiochem Div, Mumbai 400085, Maharashtra, India
关键词
Plutonium(IV) selective; Membrane; Surface grafting; Alpha spectrometry; Isotope dilution; Dissolver solutions; EXTRACTION CHROMATOGRAPHY; PLUTONIUM CONCENTRATION; ENVIRONMENTAL-SAMPLES; MASS-SPECTROMETRY; SEPARATION; ACTINIDES; SOIL; MEMBRANES;
D O I
10.1016/j.aca.2015.04.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantification of actinides in the complex environmental, biological, process and waste streams samples requires multiple steps like selective preconcentration and matrix elimination, solid source preparations generally by evaporation or electrodeposition, and finally alpha spectrometry. To minimize the sample manipulation steps, a membrane based isotope dilution alpha spectrometry method was developed for the determination of plutonium concentrations in the complex aqueous solutions. The advantages of this method are that it is Pu(IV) selective at 3 M HNO3, high preconcentration factor can be achieved, and obviates the need of solid source preparation. For this, a thin phosphate-sulfate bifunctional polymer layer was anchored on the surface of microporous poly(ethersulfone) membrane by UV induced surface grafting. The thickness of the bifunctional layer on one surface of the poly(ethersulfone) membrane was optimized. The thickness, physical and chemical structures of the bifunctional layer were studied by secondary ionization mass spectrometry (SIMS), scanning electron microscopy (SEM) and SEM-EDS (energy-dispersive spectroscopy). The optimized membrane was used for preconcentration of Pu(IV) from aqueous solutions having 3-4 M HNO3, followed by direct quantification of the preconcentrated Pu (IV) by isotope dilution alpha spectrometry using Pu-238 spike. The chemical recovery efficiency of Pu(IV) was found to be 86 +/- 3% below Pu(IV) loading capacity (1.08 mu g in 2 x 1cm(2)) of the membrane sample. The experiments with single representative actinides indicated that Am(III) did not sorb to significant extent (7%) but U(VI) sorbed with 78 +/- 3% efficiency from the solutions having 3 M HNO3 concentration. However, Pu(IV) chemical recovery in the membrane remained unaffected from the solution containing 1:1000 wt. proportion of Pu(IV) to U(VI). Pu concentrations in the (U, Pu)C samples and in the irradiated fuel dissolver solutions were determined. The results thus obtained were found to be in good agreement with those obtained by conventional alpha spectrometry, biamperometry and thermal ionization mass spectrometry. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 50 条
  • [41] Ultrafast selective quantification of methotrexate in human plasma by high-throughput MALDI-isotope dilution mass spectrometry
    Meestersy, Roland J. W.
    den Boer, Ethan
    Mathot, Ron A. A.
    de Jonge, Robert
    van Klaveren, Rob J.
    Lindemans, Jan
    Luider, Theo M.
    BIOANALYSIS, 2011, 3 (12) : 1369 - 1378
  • [42] Direct determination of urinary iodine by inductively coupled plasma mass spectrometry using isotope dilution with iodine-129
    Haldimann, M
    Zimmerli, B
    Als, C
    Gerber, H
    CLINICAL CHEMISTRY, 1998, 44 (04) : 817 - 824
  • [43] BARIUM AND STRONTIUM CONCENTRATIONS IN PACIFIC AND MEDITERRANEAN SEA-WATER PROFILES BY DIRECT ISOTOPE DILUTION MASS-SPECTROMETRY
    BERNAT, M
    ALLEGRE, CJ
    CHURCH, T
    EARTH AND PLANETARY SCIENCE LETTERS, 1972, 16 (01) : 75 - &
  • [44] DETERMINATION OF ZIRCONIUM IN U-ZR-AL AND PU-ZR-AL ALLOYS BY ISOTOPE-DILUTION THERMAL IONIZATION MASS-SPECTROMETRY
    RAMAKUMAR, KL
    SAXENA, MK
    RAMAN, VA
    SANT, VL
    KAVIMANDAN, VD
    DATTA, BP
    JAIN, HC
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 158 (01): : 13 - 21
  • [45] Chemically selective soft X-ray direct-write patterning of multilayer polymer films
    Wang, Jian
    Stoever, Harald D. H.
    Hitchcock, Adam P.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (44): : 16330 - 16338
  • [46] Analysis of plutonium isotope ratios including 238Pu/239Pu in individual U-Pu mixed oxide particles by means of a combination of alpha spectrometry and ICP-MS
    Esaka, Fumitaka
    Yasuda, Kenichiro
    Suzuki, Daisuke
    Miyamoto, Yutaka
    Magara, Masaaki
    TALANTA, 2017, 165 : 122 - 127
  • [47] ASSAY OF BLOOD AND TISSUE OXALOACETATE AND ALPHA-KETOGLUTARATE BY ISOTOPE-DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    LAPLANTE, A
    COMTE, B
    DESROSIERS, C
    ANALYTICAL BIOCHEMISTRY, 1995, 224 (02) : 580 - 587
  • [48] NEW METHOD FOR DETERMINATION OF MAJOR METABOLITE OF PROSTAGLANDIN-F2-ALPHA IN HUMAN URINE BASED ON STABLE ISOTOPE DILUTION AND GAS CHROMATOGRAPHY MASS SPECTROMETRY
    BRASH, AR
    DRAFFAN, GH
    CLARE, RA
    BAILLIE, TA
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1976, 4 (04) : 706 - 708
  • [49] Determination of Ba, Cd, Cu, Pb and Zn in saliva by isotope dilution direct injection inductively coupled plasma mass spectrometry
    Menegário, AA
    Packer, AP
    Giné, MF
    ANALYST, 2001, 126 (08) : 1363 - 1366
  • [50] Direct determination of mercury in cosmetic samples by isotope dilution inductively coupled plasma mass spectrometry after dissolution with formic acid
    Gao, Ying
    Shi, Zeming
    Zong, Qinxia
    Wu, Peng
    Su, Jing
    Liu, Rui
    ANALYTICA CHIMICA ACTA, 2014, 812 : 6 - 11