Chemically selective polymer substrate based direct isotope dilution alpha spectrometry of Pu

被引:19
|
作者
Paul, Sumana [1 ]
Pandey, Ashok K. [2 ]
Shah, R. V. [1 ]
Aggarwal, S. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiochem Div, Mumbai 400085, Maharashtra, India
关键词
Plutonium(IV) selective; Membrane; Surface grafting; Alpha spectrometry; Isotope dilution; Dissolver solutions; EXTRACTION CHROMATOGRAPHY; PLUTONIUM CONCENTRATION; ENVIRONMENTAL-SAMPLES; MASS-SPECTROMETRY; SEPARATION; ACTINIDES; SOIL; MEMBRANES;
D O I
10.1016/j.aca.2015.04.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantification of actinides in the complex environmental, biological, process and waste streams samples requires multiple steps like selective preconcentration and matrix elimination, solid source preparations generally by evaporation or electrodeposition, and finally alpha spectrometry. To minimize the sample manipulation steps, a membrane based isotope dilution alpha spectrometry method was developed for the determination of plutonium concentrations in the complex aqueous solutions. The advantages of this method are that it is Pu(IV) selective at 3 M HNO3, high preconcentration factor can be achieved, and obviates the need of solid source preparation. For this, a thin phosphate-sulfate bifunctional polymer layer was anchored on the surface of microporous poly(ethersulfone) membrane by UV induced surface grafting. The thickness of the bifunctional layer on one surface of the poly(ethersulfone) membrane was optimized. The thickness, physical and chemical structures of the bifunctional layer were studied by secondary ionization mass spectrometry (SIMS), scanning electron microscopy (SEM) and SEM-EDS (energy-dispersive spectroscopy). The optimized membrane was used for preconcentration of Pu(IV) from aqueous solutions having 3-4 M HNO3, followed by direct quantification of the preconcentrated Pu (IV) by isotope dilution alpha spectrometry using Pu-238 spike. The chemical recovery efficiency of Pu(IV) was found to be 86 +/- 3% below Pu(IV) loading capacity (1.08 mu g in 2 x 1cm(2)) of the membrane sample. The experiments with single representative actinides indicated that Am(III) did not sorb to significant extent (7%) but U(VI) sorbed with 78 +/- 3% efficiency from the solutions having 3 M HNO3 concentration. However, Pu(IV) chemical recovery in the membrane remained unaffected from the solution containing 1:1000 wt. proportion of Pu(IV) to U(VI). Pu concentrations in the (U, Pu)C samples and in the irradiated fuel dissolver solutions were determined. The results thus obtained were found to be in good agreement with those obtained by conventional alpha spectrometry, biamperometry and thermal ionization mass spectrometry. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 50 条
  • [31] Direct measurement of serum free testosterone by ultralfiltration and liquid chromatography-isotope dilution tandem mass spectrometry
    Chen, Y.
    Yazdanpanah, M.
    Wang, Y.
    Hoffman, B.
    Diamandis, E.
    Wong, P.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A178 - A178
  • [32] Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry
    Li, Xue
    Fang, Xiaowei
    Yu, Zhiqiang
    Sheng, Guoying
    Wu, Minghong
    Fu, Jiamo
    Chen, Huanwen
    ANALYTICA CHIMICA ACTA, 2012, 748 : 53 - 57
  • [33] Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry
    Li, Xue
    Fang, Xiaowei
    Yu, Zhiqiang
    Sheng, Guoying
    Wu, Minghong
    Fu, Jiamo
    Chen, Huanwen
    Analytica Chimica Acta, 2012, 748 : 53 - 57
  • [34] Direct isotope dilution measurement of trace level Cr(VI) using ion chromatography tandem mass spectrometry
    Furdui, Vasile
    Maedler, Stefanie
    Switzer, Teresa
    Sun, Fengrong
    Tat, Cindy
    Tooley, Robert
    Pamuku, Matt
    Kingston, Howard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [35] CP actuator based on chemically-deposited polypyrrole and PU based solid polymer electrolyte working in air
    Choi, Hwa Jeong
    Lim, Hyun-Ok
    Chung, Ildoo
    Ryu, Kwang-Sun
    Jo, Nam-Ju
    INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, PTS 1-3, 2007, 6423
  • [36] Application of isotope-dilution laser ablation ICP–MS for direct determination of Pu concentrations in soils at pg g−1 levels
    Sergei F. Boulyga
    Markus Tibi
    Klaus G. Heumann
    Analytical and Bioanalytical Chemistry, 2004, 378 : 342 - 347
  • [37] Development of an isotope dilution mass spectrometry assay for the quantification of insulin based on signature peptide analysis
    Ma, Shangying
    He, Rimei
    Jiang, Tingting
    Hu, Zhishang
    Ye, Zihong
    Mi, Wei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (12) : 3085 - 3096
  • [38] Development of an isotope dilution mass spectrometry assay for the quantification of insulin based on signature peptide analysis
    Shangying Ma
    Rimei He
    Tingting Jiang
    Zhishang Hu
    Zihong Ye
    Wei Mi
    Analytical and Bioanalytical Chemistry, 2024, 416 : 3085 - 3096
  • [39] ISOTOPE-DILUTION ALPHA-SPECTROMETRY WITH SPIKE ENRICHED IN U-233 FOR THE DETERMINATION OF URANIUM IN GEOLOGICAL SAMPLES
    SHIHOMATSU, HM
    IYER, SS
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1988, 128 (05): : 393 - 401
  • [40] An accurate and transferable protocol for reproducible quantification of organic pollutants in human serum using direct isotope dilution mass spectrometry
    Boggess, Andrew J.
    Rahman, G. M. Mizanur
    Pamukcu, Matt
    Faber, Scott
    Kingston, H. M. Skip
    ANALYST, 2014, 139 (23) : 6223 - 6231