Chemically selective polymer substrate based direct isotope dilution alpha spectrometry of Pu

被引:19
|
作者
Paul, Sumana [1 ]
Pandey, Ashok K. [2 ]
Shah, R. V. [1 ]
Aggarwal, S. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiochem Div, Mumbai 400085, Maharashtra, India
关键词
Plutonium(IV) selective; Membrane; Surface grafting; Alpha spectrometry; Isotope dilution; Dissolver solutions; EXTRACTION CHROMATOGRAPHY; PLUTONIUM CONCENTRATION; ENVIRONMENTAL-SAMPLES; MASS-SPECTROMETRY; SEPARATION; ACTINIDES; SOIL; MEMBRANES;
D O I
10.1016/j.aca.2015.04.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantification of actinides in the complex environmental, biological, process and waste streams samples requires multiple steps like selective preconcentration and matrix elimination, solid source preparations generally by evaporation or electrodeposition, and finally alpha spectrometry. To minimize the sample manipulation steps, a membrane based isotope dilution alpha spectrometry method was developed for the determination of plutonium concentrations in the complex aqueous solutions. The advantages of this method are that it is Pu(IV) selective at 3 M HNO3, high preconcentration factor can be achieved, and obviates the need of solid source preparation. For this, a thin phosphate-sulfate bifunctional polymer layer was anchored on the surface of microporous poly(ethersulfone) membrane by UV induced surface grafting. The thickness of the bifunctional layer on one surface of the poly(ethersulfone) membrane was optimized. The thickness, physical and chemical structures of the bifunctional layer were studied by secondary ionization mass spectrometry (SIMS), scanning electron microscopy (SEM) and SEM-EDS (energy-dispersive spectroscopy). The optimized membrane was used for preconcentration of Pu(IV) from aqueous solutions having 3-4 M HNO3, followed by direct quantification of the preconcentrated Pu (IV) by isotope dilution alpha spectrometry using Pu-238 spike. The chemical recovery efficiency of Pu(IV) was found to be 86 +/- 3% below Pu(IV) loading capacity (1.08 mu g in 2 x 1cm(2)) of the membrane sample. The experiments with single representative actinides indicated that Am(III) did not sorb to significant extent (7%) but U(VI) sorbed with 78 +/- 3% efficiency from the solutions having 3 M HNO3 concentration. However, Pu(IV) chemical recovery in the membrane remained unaffected from the solution containing 1:1000 wt. proportion of Pu(IV) to U(VI). Pu concentrations in the (U, Pu)C samples and in the irradiated fuel dissolver solutions were determined. The results thus obtained were found to be in good agreement with those obtained by conventional alpha spectrometry, biamperometry and thermal ionization mass spectrometry. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 50 条
  • [1] Effect of radioactive decay of Pu isotopes on the determination of Pu concentration with high accuracy by isotope dilution mass spectrometry (IDMS) and isotope dilution alpha spectrometry (IDAS)
    Alamelu, D.
    Aggarwal, S. K.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2007, 444 : 643 - 646
  • [2] Effect of radioactive decay of Pu isotopes on the determination of Pu concentration with high accuracy by isotope dilution mass spectrometry (IDMS) and isotope dilution alpha spectrometry (IDAS)
    Alamelu, D.
    Aggarwal, S.K.
    Journal of Alloys and Compounds, 2007, 444-445 (SPEC. ISS.): : 643 - 646
  • [3] Isotope dilution gamma spectrometry for Pu using low energy photons
    Paul, S.
    Sarkar, A.
    Alamelu, D.
    Shah, R. V.
    Aggarwal, S. K.
    RADIOCHIMICA ACTA, 2012, 100 (05) : 291 - 296
  • [4] determination of 239,240Pu in soil by isotope dilution-α spectrometry
    Wu, Lun-Qiang
    Yang, Ming-Tai
    Xiang, Fang-Shou
    Gao, Ge
    Liu, Jun
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 2002, 24 (04):
  • [5] Measurement of Alpha-Fetoprotein by Isotope Dilution Mass Spectrometry
    Liu Y.
    Song D.-W.
    Zhang F.-Y.
    Li H.-M.
    Xu B.
    Dai X.-H.
    Sun H.-Y.
    Chen B.-R.
    Song, De-Wei (songdw@nim.ac.cn), 1600, Chinese Society for Mass Spectrometry (38): : 640 - 646
  • [6] Determination of the isotope composition and content of U and Pu in environmental samples on the ultrasmall level by isotope dilution mass spectrometry
    Stepanov A.V.
    Makarova T.P.
    Domkin V.D.
    Pevtsova E.V.
    Aleksandruk V.M.
    Nikolaeva O.V.
    Chubinskii-Nadezhdin I.V.
    Kulikov Yu.V.
    Radiochemistry, 2004, 46 (5) : 500 - 507
  • [7] ON THE CAPABILITIES OF ISOTOPE-DILUTION ALPHA SPECTROMETRY IN THE DETERMINATION OF PLUTONIUM CONCENTRATION
    PARUS, J
    RAAB, W
    SWIETLY, H
    CAPPIS, J
    DERON, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2): : 278 - 283
  • [8] PREPARATION OF A PU-238 STANDARD SOURCE .1. ISOTOPE-DILUTION ALPHA-RAY SPECTROMETRY USED FOR STANDARDIZATION
    SHINOHARA, N
    KOHNO, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 270 (2-3): : 239 - 242
  • [9] HALF-LIFE OF PU-241 BY AM-241 GROWTH METHOD USING ISOTOPE-DILUTION ALPHA SPECTROMETRY
    AGGARWAL, SK
    ACHARYA, SN
    PARAB, AR
    JAIN, HC
    RADIOCHIMICA ACTA, 1981, 29 (2-3) : 65 - 69
  • [10] PREPARATION OF A 238Pu STANDARD SOURCE. I. ISOTOPE DILUTION ALPHA-RAY SPECTROMETRY USED FOR STANDARDIZATION.
    Shinohara, Nubuo
    Kohno, Nobuaki
    Nuclear instruments and methods in physics research, 1988, A270 (2-3): : 239 - 242