Comparison of corona degree between the stranded and the shaped wires of HVDC transmission lines

被引:1
|
作者
Mo, Juan [1 ,2 ]
Zhou, Chao [3 ]
Yuan, Jiansheng [4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian, Shaanxi, Peoples R China
[2] China Elect Power Res Inst, Beijing, Peoples R China
[3] Shandong Elect Power Res Inst, Jinan, Shandong, Peoples R China
[4] Tsinghua Univ, Dept Elect Engn, Beijing, Peoples R China
关键词
Corona loss; high voltage transmission line; shaped wire; stranded wire; DISCHARGES;
D O I
10.3233/JAE-170065
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most of high voltage transmission lines use the stranded wire, while the surface of the shaped wire is smoother than the stranded one. It is investigated in this paper that how much the corona can be weakened by the shaped wire, by calculating the ion flow. The steady state corona model is employed, and a local domain surrounding the wire is chosen as the field domain to simulate the corona phenomena near the wire precisely. The equation system of corona model is a multi-physics coupled problem with electric field and particle diffusion and migration. The approach of defining and applying the boundary conditions for negative and positive wires is proposed, and the solution of coupled problem is implemented by using software COMSOL. By the simulation of 500 kV transmission line, the corona current of the shaped wire is around 35% less than that of the stranded wire.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [41] A New AC/DC Converter for the Interconnections between Wind Farms and HVDC Transmission Lines
    Nouri, Soheil
    Babaei, Ebrahim
    Hosseini, Seyyed Hossein
    JOURNAL OF POWER ELECTRONICS, 2014, 14 (03) : 592 - 597
  • [42] Comparison between theory and experiment in T-shaped quantum well wires
    Brinkmann, D
    Fishman, G
    MICROELECTRONICS JOURNAL, 1997, 28 (8-10) : 1037 - 1041
  • [43] A current differential protection using time-domain waveform comparison for HVDC transmission lines
    School of Electrical Engineering, Xi'an Jiaotong University, Xi'an
    710049, China
    不详
    710054, China
    Dianli Xitong Zidonghue, 24 (87-95):
  • [44] Fast Corona Discharge Assessment Using FDM integrated With Full Multigrid Method in HVDC Transmission Lines Considering Wind Impact
    Abouelatta, Mohamed A.
    Ward, Sayed A.
    Sayed, Ahmad M.
    Mahmoud, Karar
    Lehtonen, Matti
    Darwish, Mohamed M. F.
    IEEE ACCESS, 2020, 8 (08): : 225872 - 225883
  • [45] MUTUAL CAPACITANCE BETWEEN GROUND WIRES AND PHASE CONDUCTORS OF EHV TRANSMISSION-LINES
    JOHNSON, GL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (06): : 2264 - &
  • [46] Between Wires and Wings: What Are the Impacts of Power Transmission Lines on the Diversity of Insectivorous Bats?
    Falcao, Fabio
    Mira-Mendes, Caio Vinicius de
    Herrera-Lopera, Jorge Mario
    SUSTAINABILITY, 2024, 16 (13)
  • [47] Traveling Wave Current Polarity Comparison Protection Using Wavelet Modulus Maxima for HVDC Transmission Lines
    Duan Jiandong
    Lu Wen
    An Lin
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 5327 - +
  • [48] INTENSITY OF EMISSION LINES OF THE QUIESCENT SOLAR CORONA: COMPARISON BETWEEN CALCULATED AND OBSERVED VALUES
    Krissinel, B. B.
    SOLAR-TERRESTRIAL PHYSICS, 2018, 4 (01): : 12 - 24
  • [49] Environmental Licensing Comparison between Brazil and European Union for Transmission Lines
    Brandao, Flavia de Paiva
    Felix Cardoso Junior, Ricardo Abrauches
    2013 4TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY (IYCE), 2013,
  • [50] Identification of transmission lines: A comparison between the Laplace domain and the Warburg domain
    De Block, W
    Rolain, Y
    IMTC/2000: PROCEEDINGS OF THE 17TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE: SMART CONNECTIVITY: INTEGRATING MEASUREMENT AND CONTROL, 2000, : 891 - 896