Comparison of corona degree between the stranded and the shaped wires of HVDC transmission lines

被引:1
|
作者
Mo, Juan [1 ,2 ]
Zhou, Chao [3 ]
Yuan, Jiansheng [4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian, Shaanxi, Peoples R China
[2] China Elect Power Res Inst, Beijing, Peoples R China
[3] Shandong Elect Power Res Inst, Jinan, Shandong, Peoples R China
[4] Tsinghua Univ, Dept Elect Engn, Beijing, Peoples R China
关键词
Corona loss; high voltage transmission line; shaped wire; stranded wire; DISCHARGES;
D O I
10.3233/JAE-170065
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most of high voltage transmission lines use the stranded wire, while the surface of the shaped wire is smoother than the stranded one. It is investigated in this paper that how much the corona can be weakened by the shaped wire, by calculating the ion flow. The steady state corona model is employed, and a local domain surrounding the wire is chosen as the field domain to simulate the corona phenomena near the wire precisely. The equation system of corona model is a multi-physics coupled problem with electric field and particle diffusion and migration. The approach of defining and applying the boundary conditions for negative and positive wires is proposed, and the solution of coupled problem is implemented by using software COMSOL. By the simulation of 500 kV transmission line, the corona current of the shaped wire is around 35% less than that of the stranded wire.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [31] Simulation of Impulse Corona on HVDC Overhead Transmission Lines With Background DC Space Charges by Method of Characteristics
    Zhang, Bo
    Xiao, Fengnyu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (03) : 2032 - 2039
  • [32] Behavior comparison of corona inception and flashover voltage between HVAC and HVDC insulator
    Karn, A.
    Potivejkul, S.
    Pattanadech, N.
    Yutthagowith, P.
    IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 334 - 338
  • [33] A NEW ALGORITHM FOR EVALUATING THE FIELDS ASSOCIATED WITH HVDC POWER TRANSMISSION-LINES IN THE PRESENCE OF CORONA AND STRONG WIND
    YU, M
    KUFFEL, E
    IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (02) : 1985 - 1988
  • [34] Calculation of Ion-Flow Field Near the Crossing of HVdc Transmission Lines Using Equivalent Corona Conductors
    Wang, Donglai
    Lu, Tiebing
    Hao, Liming
    Zhang, Qian
    Chen, Bo
    Li, Xuebao
    IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (08)
  • [35] Measurement of Corona Characteristics and Electromagnetic Environment of ±800 kV HVDC Transmission Lines under High Altitude Condition
    Zhang, Zheng
    Zeng, Rong
    Yu, Zhanqing
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 61 - 65
  • [36] Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line
    Liu, Yingyi
    Zhou, Lijuan
    Liu, Yuanqing
    Yuan, Haiwen
    Ji, Liang
    PHYSICS OF PLASMAS, 2017, 24 (11)
  • [37] Reliability analysis and comparison of long-distance HVAC and HVDC power transmission lines
    Alekseeva, ND
    Bubnova, AV
    Chudny, VS
    Tikhodeev, NN
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 375 - 379
  • [39] Clinical comparison between Multi-Stranded Wires and Single strand Ribbon wires used for lingual fixed retainers
    Valiollah Arash
    Mehran Teimoorian
    Yasamin Farajzadeh Jalali
    Sedigheh Sheikhzadeh
    Progress in Orthodontics, 21
  • [40] Clinical comparison between Multi-Stranded Wires and Single strand Ribbon wires used for lingual fixed retainers
    Arash, Valiollah
    Teimoorian, Mehran
    Farajzadeh Jalali, Yasamin
    Sheikhzadeh, Sedigheh
    PROGRESS IN ORTHODONTICS, 2020, 21 (01)