Comparison of corona degree between the stranded and the shaped wires of HVDC transmission lines

被引:1
|
作者
Mo, Juan [1 ,2 ]
Zhou, Chao [3 ]
Yuan, Jiansheng [4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian, Shaanxi, Peoples R China
[2] China Elect Power Res Inst, Beijing, Peoples R China
[3] Shandong Elect Power Res Inst, Jinan, Shandong, Peoples R China
[4] Tsinghua Univ, Dept Elect Engn, Beijing, Peoples R China
关键词
Corona loss; high voltage transmission line; shaped wire; stranded wire; DISCHARGES;
D O I
10.3233/JAE-170065
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most of high voltage transmission lines use the stranded wire, while the surface of the shaped wire is smoother than the stranded one. It is investigated in this paper that how much the corona can be weakened by the shaped wire, by calculating the ion flow. The steady state corona model is employed, and a local domain surrounding the wire is chosen as the field domain to simulate the corona phenomena near the wire precisely. The equation system of corona model is a multi-physics coupled problem with electric field and particle diffusion and migration. The approach of defining and applying the boundary conditions for negative and positive wires is proposed, and the solution of coupled problem is implemented by using software COMSOL. By the simulation of 500 kV transmission line, the corona current of the shaped wire is around 35% less than that of the stranded wire.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] DEGREE OF CORONA SATURATION FOR HVDC TRANSMISSION-LINES
    JOHNSON, GB
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (02) : 695 - 707
  • [2] COMPUTATION OF CORONA CHARACTERISTICS FOR STRANDED ELECTRICAL TRANSMISSION LINES
    ALEKSANDROV, GN
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1957, 2 (04): : 711 - 728
  • [3] Optimization of Corona Radio Interference Levels in HVDC Transmission Lines
    Tejada-Martinez, Carlos
    Espino-Cortes, Fermin P.
    Ilhan, Suat
    Ozdemir, Aydogan
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [4] Computation of Corona Radio Interference Levels in HVDC Transmission Lines
    Tejada-Martinez, Carlos
    Espino-Cortes, Fermin P.
    Ilhan, Suat
    Ozdemir, Aydogan
    2017 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2017, : 206 - 210
  • [5] Analysis of the relationship between DC component and spectral components of corona current on HVDC transmission lines
    Liu, Yingyi
    Liu, Yuanqing
    Cui, Yong
    Yuan, Haiwen
    Lv, Jianxun
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (10) : 1952 - 1959
  • [6] CORONA LOSS CHARACTERISTICS OF PRACTICAL HVDC TRANSMISSION LINES .2. BIOPOLAR LINES
    SARMA, MP
    JANISCHE.W
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (03): : 1055 - &
  • [7] On the corona voltage-current characteristic of unipolar HVDC transmission lines
    Li, X
    Raghuveer, MR
    Ciric, IR
    IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 654 - 657
  • [8] Influence of Ambient Electric Field on the Corona Performance of HVdc Transmission Lines
    Maruvada, P. Sarma
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) : 691 - 698
  • [9] Noise Suppression of Corona Current Measurement From HVdc Transmission Lines
    Wang, Qiusheng
    Kundur, Deepa
    Yuan, Haiwen
    Liu, Yuanqing
    Lu, Jiayu
    Ma, Zhao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (02) : 264 - 275
  • [10] CORONA LOSS CHARACTERISTICS OF PRACTICAL HVDC TRANSMISSION LINES .1. UNIPOLAR LINES
    SARMA, MP
    JANISCHE.W
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (05): : 860 - &