A 2D spiral turbo-spin-echo technique

被引:17
|
作者
Li, Zhiqiang [1 ]
Karis, John P. [2 ]
Pipe, James G. [1 ]
机构
[1] Barrow Neurol Inst, Imaging Res, Phoenix, AZ 85013 USA
[2] Barrow Neurol Inst, Dept Neuroradiol, Phoenix, AZ 85013 USA
关键词
SAR; spiral; 2D TSE; BRAIN; MR; SEQUENCES; CONTRAST; SENSITIVITY; HEMORRHAGE; BEHAVIOR; DESIGN; SCANS; FIELD;
D O I
10.1002/mrm.27171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: 2D turbo-spin-echo (TSE) is widely used in the clinic for neuroimaging. However, the long refocusing radiofrequency pulse train leads to high specific absorption rate (SAR) and alters the contrast compared to conventional spin-echo. The purpose of this work is to develop a robust 2D spiral TSE technique for fast T-2-weighted imaging with low SAR and improved contrast. Methods: A spiral-in/out readout is incorporated into 2D TSE to fully take advantage of the acquisition efficiency of spiral sampling while avoiding potential off-resonance-related artifacts compared to a typical spiral- out readout. A double encoding strategy and a signal demodulation method are proposed to mitigate the artifacts because of the T-2-decay-induced signal variation. An adapted prescan phase correction as well as a concomitant phase compensation technique are implemented to minimize the phase errors. Results: Phantom data demonstrate the efficacy of the proposed double encoding/signal demodulation, as well as the prescan phase correction and concomitant phase compensation. Volunteer data show that the proposed 2D spiral TSE achieves fast scan speed with high SNR, low SAR, and improved contrast compared to conventional Cartesian TSE. Conclusion: A robust 2D spiral TSE technique is feasible and provides a potential alternative to conventional 2D Cartesian TSE for T-2-weighted neuroimaging.
引用
收藏
页码:1989 / 1996
页数:8
相关论文
共 50 条
  • [41] ELECTRON-SPIN-ECHO-DETECTED 2D EPR SPECTROSCOPY
    ZHONG, YC
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (01) : 117 - 120
  • [42] MULTIPLE-SPIN-ECHO IMAGING WITH A 2D FOURIER METHOD
    GRAUMANN, R
    OPPELT, A
    STETTER, E
    MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) : 707 - 721
  • [43] Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images
    Sylvain R. Duc
    Bernard Mengiardi
    Christian W. A. Pfirrmann
    Juerg Hodler
    Marco Zanetti
    European Radiology, 2007, 17 : 1162 - 1171
  • [44] Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images
    Duc, Sylvain R.
    Mengiardi, Bernard
    Pfirrmann, Christian W. A.
    Hodler, Juerg
    Zanetti, Marco
    EUROPEAN RADIOLOGY, 2007, 17 (05) : 1162 - 1171
  • [45] Pancreaticobiliary diseases - Comparison of 2D single-shot turbo spin-echo MR cholangiopancreatography with endoscopic retrograde cholangiopancreatography
    Arslan, A
    Geitung, JT
    Viktil, E
    Abdelnoor, M
    Osnes, M
    ACTA RADIOLOGICA, 2000, 41 (06) : 621 - 626
  • [46] A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo
    Li, Z.
    Hu, H. H.
    Miller, J. H.
    Karis, J. P.
    Cornejo, P.
    Wang, D.
    Pipe, J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 642 - 647
  • [47] CINE Turbo Spin Echo Imaging
    Mendes, Jason
    Parker, Dennis L.
    Hulet, Jordan
    Treiman, Gerald S.
    Kim, Seong-Eun
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (05) : 1286 - 1292
  • [48] The feasibility of a radial turbo-spin-echo T2 mapping for preoperative prediction of the histological grade and lymphovascular space invasion of cervical squamous cell carcinoma
    Li, Shujian
    Zhang, Zanxia
    Liu, Jie
    Zhang, Feifei
    Yang, Meng
    Lu, Huifang
    Zhang, Yong
    Han, Fei
    Cheng, Jingliang
    Zhu, Jinxia
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139
  • [49] 2D photon echo
    Noriaki Horiuchi
    Nature Photonics, 2016, 10 (12) : 751 - 751
  • [50] Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging
    Zhang, Qinwei
    van Houdt, Petra J.
    Lambregts, Doenja M. J.
    van Triest, Baukelien
    Kop, Marnix P. M.
    Coolen, Bram F.
    Strijkers, Gustav J.
    van der Heide, Uulke A.
    Nederveen, Aart J.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)