A 2D spiral turbo-spin-echo technique

被引:17
|
作者
Li, Zhiqiang [1 ]
Karis, John P. [2 ]
Pipe, James G. [1 ]
机构
[1] Barrow Neurol Inst, Imaging Res, Phoenix, AZ 85013 USA
[2] Barrow Neurol Inst, Dept Neuroradiol, Phoenix, AZ 85013 USA
关键词
SAR; spiral; 2D TSE; BRAIN; MR; SEQUENCES; CONTRAST; SENSITIVITY; HEMORRHAGE; BEHAVIOR; DESIGN; SCANS; FIELD;
D O I
10.1002/mrm.27171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: 2D turbo-spin-echo (TSE) is widely used in the clinic for neuroimaging. However, the long refocusing radiofrequency pulse train leads to high specific absorption rate (SAR) and alters the contrast compared to conventional spin-echo. The purpose of this work is to develop a robust 2D spiral TSE technique for fast T-2-weighted imaging with low SAR and improved contrast. Methods: A spiral-in/out readout is incorporated into 2D TSE to fully take advantage of the acquisition efficiency of spiral sampling while avoiding potential off-resonance-related artifacts compared to a typical spiral- out readout. A double encoding strategy and a signal demodulation method are proposed to mitigate the artifacts because of the T-2-decay-induced signal variation. An adapted prescan phase correction as well as a concomitant phase compensation technique are implemented to minimize the phase errors. Results: Phantom data demonstrate the efficacy of the proposed double encoding/signal demodulation, as well as the prescan phase correction and concomitant phase compensation. Volunteer data show that the proposed 2D spiral TSE achieves fast scan speed with high SNR, low SAR, and improved contrast compared to conventional Cartesian TSE. Conclusion: A robust 2D spiral TSE technique is feasible and provides a potential alternative to conventional 2D Cartesian TSE for T-2-weighted neuroimaging.
引用
收藏
页码:1989 / 1996
页数:8
相关论文
共 50 条
  • [31] Compressed SENSE accelerated 3D T1w black blood turbo spin echo versus 2D T1w turbo spin echo sequence in pituitary magnetic resonance imaging
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    Wyss, Michael
    Schwenk, Arpad
    van Smoorenburg, Luuk
    Eichenberger, Barbara
    Najafi, Arash
    Binkert, Christoph
    Becker, Anton S.
    Sartoretti-Schefer, Sabine
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 120
  • [32] Rapid and motion-robust pediatric brain imaging: T2-weighted turbo-spin-echo PROPELLER acquisition with compressed sensing
    Wichtmann, Barbara Daria
    Katemann, Christoph
    Kadrija, Mergim
    Layer, Yannik C.
    Bischoff, Leon M.
    Scheuver, Yvonne
    Mezger, Madeleine
    Weber, Oliver M.
    Luetkens, Julian A.
    Attenberger, Ulrike I.
    Radbruch, Alexander
    Paech, Daniel
    PEDIATRIC RADIOLOGY, 2025, 55 (01) : 183 - 194
  • [33] Comparison of 3D turbo spin-echo SPACE sequences with conventional 2D MRI sequences to assess the shoulder joint
    Kloth, Jost Karsten
    Winterstein, Marianne
    Akbar, Michael
    Meyer, Esther
    Paul, Dominik
    Kauczor, Haus-Ulrich
    Weber, Marc-Andre
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1843 - 1849
  • [34] Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP
    Felix Christian Hasse
    Buket Selmi
    Hamed Albusaidi
    Theresa Mokry
    Philipp Mayer
    Christian Rupp
    Hans-Ulrich Kauczor
    Tim Frederik Weber
    BMC Medical Imaging, 21
  • [35] Evaluation of a single-breath-hold radial turbo-spin-echo sequence for T2 mapping of the liver at 3T
    Bencikova, Dianas
    Han, Fei
    Kannengieser, Stephan
    Raudner, Marcus
    Poetter-Lang, Sarah
    Bastati, Nina
    Reiter, Gert
    Ambros, Raphael
    Ba-Ssalamah, Ahmed
    Trattnig, Siegfried
    Krssak, Martin
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 3388 - 3397
  • [36] MRI of the regions of inner ear and cerebellopontine angle using a 3D T-2-weighted turbo spin-echo sequence: Comparison with conventional 2D T-2-weighted turbo spin-echo sequences and T-1-weighted spin-echo sequences.
    Czerny, C
    Trattnig, S
    Baumgartner, WD
    Gstottner, W
    Imhof, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04): : 377 - 383
  • [37] Reducing Contrast Contamination in Radial Turbo-Spin-Echo Acquisitions by Combining a Narrow-Band KWIC Filter with Parallel Imaging
    Neumann, Daniel
    Breuer, Felix A.
    Voelker, Michael
    Brandt, Tobias
    Griswold, Mark A.
    Jakob, Peter M.
    Blaimer, Martin
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) : 1680 - 1686
  • [38] Three-dimensional spiral fMRI technique: A comparison with 2D spiral acquisition
    Lai, S
    Glover, GH
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) : 68 - 78
  • [39] ULTRAFAST BIOMECHANICAL T2 MAPPING OF KNEE ARTICULAR CARTILAGE USING A RADIAL TURBO-SPIN-ECHO SEQUENCE AT 3TINITIAL RESULTS
    Janacova, V.
    Juras, V.
    Szomolanyi, P.
    Bencikova, D.
    Trattnig, S.
    OSTEOARTHRITIS AND CARTILAGE, 2023, 31 : S267 - S268
  • [40] Three-dimensional turbo-spin-echo amide proton transfer-weighted mri for cervical cancer: A preliminary study
    He, Yong-Lan
    Li, Yuan
    Lin, Cheng-Yu
    Qi, Ya-Fei
    Wang, Xiaoqi
    Zhou, Hai-Long
    Yang, Jun-Jun
    Xiang, Yang
    Xue, Hua-Dan
    Jin, Zheng-Yu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) : 1318 - 1325