Simultaneous optimization of design and operation of an air-cooled geothermal ORC under consideration of multiple operating points

被引:8
|
作者
Langiu, Marco
Dahmen, Manuel
Mitsos, Alexander
机构
[1] Forschungszentrum Julich GmbH, Institute of Energy and Climate Research, Energy Systems Engineering (IEK-10), Julich
[2] JARA-ENERGY, Julich
[3] RWTH Aachen University, Process Systems Engineering (AVT.SVT), Aachen
关键词
Design and operation; ORC; Optimization; Two-stage stochastic programming; Artificial neural networks; ORGANIC RANKINE-CYCLE; WASTE HEAT-RECOVERY; OFF-DESIGN; POWER-PLANTS; NUMERICAL OPTIMIZATION; GLOBAL OPTIMIZATION; GENERAL CORRELATION; WORKING FLUID; PART; SYSTEMS;
D O I
10.1016/j.compchemeng.2022.107745
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We simultaneously optimize both the design and operation of an air-cooled geothermal organic Rankine cycle, maximizing total annual return (TAR), while considering multiple operating scenarios based on different ambient temperatures. In order to accurately capture realistic off-design behavior of the heat exchangers and turbine, as well as for the overall system, we incorporate component models that consider performance variations with both size and operating conditions. We employ a hybrid mechanistic data-driven modeling approach, involving artificial neural networks (ANNs) as surrogate models for accurate fluid properties, as well as for intermediate expressions for which ANNs improve tractability of the optimization problem. We demonstrate the importance of considering multiple operating conditions within design problems and propose a methodology for formulating and solving such problems globally, using our open-source solver MAiNGO. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Optimization Design of Refuse-Incinerating Power Plant With Air-Cooled Heat Exchanger
    Zhang, Dongjie
    Chen, Qin
    Wang, Qiuwang
    Xu, Xiangyang
    HEAT TRANSFER ENGINEERING, 2014, 35 (6-8) : 711 - 720
  • [22] Economic system optimization of air-cooled organic Rankine cycles powered by low-temperature geothermal heat sources
    Walraven, Daniel
    Laenen, Ben
    D'haeseleer, William
    ENERGY, 2015, 80 : 104 - 113
  • [23] Operation characteristics of air-cooled proton exchange membrane fuel cell stacks under ambient pressure
    Pei, Houchang
    Shen, Jun
    Cai, Yonghua
    Tu, Zhengkai
    Wan, Zhongmin
    Liu, Zhichun
    Liu, Wei
    APPLIED THERMAL ENGINEERING, 2014, 63 (01) : 227 - 233
  • [24] Temperature profiles of an air-cooled PEM fuel cell stack under active and passive cooling operation
    Atan, R.
    Najmi, W. A. W. M.
    INTERNATIONAL SYMPOSIUM ON ROBOTICS AND INTELLIGENT SENSORS 2012 (IRIS 2012), 2012, 41 : 1735 - 1742
  • [25] NUMERICAL INVESTIGATION AND PERFORMANCE OPTIMIZATION OF AN AIR-COOLED STEAM CONDENSER CELL UNDER AMBIENT CONDITIONS
    He, Weifeng
    Dai, Yiping
    Ma, Qingzhong
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 5, PTS A AND B, 2012, : 2061 - 2068
  • [26] Configuration, design, and optimization of air-cooled battery thermal management system for electric vehicles: A review
    Akinlabi, A. Hakeem
    Solyali, Davut
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 125
  • [27] Design and operation of the air-cooled beam dump for the extraction line of CERN's proton synchrotron booster
    Perillo-Marcone, A.
    Calviani, M.
    Solieri, N.
    Ciccotelli, A.
    Kaiser, P.
    Sarrio, A.
    Venturi, V.
    Vlachoudis, V.
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2020, 23 (06):
  • [28] Optimization design of the forced air-cooled battery thermal management system with a stepped divergence plenum
    Suo, Yaohong
    Tang, Chengbo
    Yang, Huai
    JOURNAL OF ENERGY STORAGE, 2023, 73
  • [29] A CFD-based design optimization of air-cooled passive decay heat removal system
    Kim, Do Yun
    No, Hee Cheon
    NUCLEAR ENGINEERING AND DESIGN, 2018, 337 : 351 - 363
  • [30] Operation optimization of cold-end system of direct air-cooled units considering the effect of environmental wind
    Zhu, Xingrong
    Zhan, Jianyong
    HEAT TRANSFER, 2023, 52 (06) : 4337 - 4356