Streaming architectures for cone-beam CT image reconstruction and deformable registration

被引:0
|
作者
Singh, H.
Kandasamy, N.
Folkert, M.
Sharp, G.
机构
[1] Drexel Univ, Philadelphia, PA 19104 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
D O I
10.1118/1.2761696
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop data‐parallel algorithms for tomographic reconstruction and deformable registration within a stream‐processing paradigm, and execute them on cheap stream processors such as graphics processing units (GPUs). Method and Materials: In the computer sciences, the stream‐processing paradigm is emerging as a cost‐effective way of solving large‐scale parallel computing problems. This is due to the recent introduction of high‐performance stream‐processing hardware such as the Cell processor and GPUs—both are commodity stream (or vector) processors, designed specifically to support large‐scale parallel computing on a single chip. This presentation describes how to use the stream‐processing model to significantly accelerate the complex problems of data reconstruction and fusion for radiotherapy. Highly data‐parallel models were developed for: (1) the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm, and (2) Demon's algorithm for optical‐flow based deformable registration. These models were implemented within the Brook programming environment and executed on an nVIDIA 8800 GPU. Results: The performance of GPU‐based implementations of the FDK and Demon's algorithms was analyzed using data obtained from an IGRT testbed of a preserved swine lung. The results indicate a substantial speedup of up to 17 times for FDK, and up to 33 times for Demons, when compared with a 2.4 GHz Intel Duo‐Core processor. In addition, the GPU was found to be capable of high‐quality reconstructions, with differences within a few Hounsfield unit. Conclusions: Results indicate that data‐parallel image‐processing algorithms, when properly designed and executed on a GPU, achieve significant speedup when compared to high‐end desktop CPUs. The acceleration of key data‐processing stages will decrease the time needed to perform image‐guided patient positioning and analysis. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2634 / 2634
页数:1
相关论文
共 50 条
  • [21] Evaluation of Registration Accuracy for Cone-Beam CT Reconstruction Techniques
    Li, J.
    Zhang, H.
    Wang, P.
    MEDICAL PHYSICS, 2016, 43 (06) : 3656 - 3657
  • [22] Cone-Beam CT Reconstruction with Deformed Prior Image
    Zhang, H.
    Ouyang, L.
    Huang, J.
    Ma, J.
    Chen, W.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527
  • [23] Cone-Beam CT Image Reconstruction with Spherical Harmonics
    Shimomura, T.
    Haga, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E391 - E392
  • [24] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [25] Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery
    Reaungamornrat, S.
    Wang, A. S.
    Uneri, A.
    Otake, Y.
    Khanna, A. J.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3761 - 3787
  • [26] Deformable image registration for cone-beam CT guided transoral robotic base-of-tongue surgery
    Reaungamornrat, S.
    Liu, W. P.
    Swang, A.
    Otake, Y.
    Nithiananthan, S.
    Uneri, A.
    Schafer, S.
    Tryggestad, E.
    Richmon, J.
    Sorger, J. M.
    Siewerdsen, J. H.
    Taylor, R. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14): : 4951 - 4979
  • [27] Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Stayman, J. Webster
    Zbijewski, Wojciech
    Brock, Kristy K.
    Daly, Michael J.
    Chan, Harley
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2011, 38 (04) : 1785 - 1798
  • [28] A Hybrid Deformable Registration Method between Helical CT and Cone-Beam CT for Prostate Patient
    Qin, A.
    Liang, J.
    Yan, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Evaluation of the Performance of a New Deformable Image Registration Algorithms Based On Motion Modeling for Cone-Beam CT Images
    Alsbou, N.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2017, 44 (06) : 3212 - 3213
  • [30] OR-EM Method for Image Reconstruction in Cone-beam CT
    Dong, Baoyu
    PROCEEDINGS OF THE FIRST INTERNATIONAL WORKSHOP ON EDUCATION TECHNOLOGY AND COMPUTER SCIENCE, VOL I, 2009, : 635 - 639