Streaming architectures for cone-beam CT image reconstruction and deformable registration

被引:0
|
作者
Singh, H.
Kandasamy, N.
Folkert, M.
Sharp, G.
机构
[1] Drexel Univ, Philadelphia, PA 19104 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
D O I
10.1118/1.2761696
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop data‐parallel algorithms for tomographic reconstruction and deformable registration within a stream‐processing paradigm, and execute them on cheap stream processors such as graphics processing units (GPUs). Method and Materials: In the computer sciences, the stream‐processing paradigm is emerging as a cost‐effective way of solving large‐scale parallel computing problems. This is due to the recent introduction of high‐performance stream‐processing hardware such as the Cell processor and GPUs—both are commodity stream (or vector) processors, designed specifically to support large‐scale parallel computing on a single chip. This presentation describes how to use the stream‐processing model to significantly accelerate the complex problems of data reconstruction and fusion for radiotherapy. Highly data‐parallel models were developed for: (1) the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm, and (2) Demon's algorithm for optical‐flow based deformable registration. These models were implemented within the Brook programming environment and executed on an nVIDIA 8800 GPU. Results: The performance of GPU‐based implementations of the FDK and Demon's algorithms was analyzed using data obtained from an IGRT testbed of a preserved swine lung. The results indicate a substantial speedup of up to 17 times for FDK, and up to 33 times for Demons, when compared with a 2.4 GHz Intel Duo‐Core processor. In addition, the GPU was found to be capable of high‐quality reconstructions, with differences within a few Hounsfield unit. Conclusions: Results indicate that data‐parallel image‐processing algorithms, when properly designed and executed on a GPU, achieve significant speedup when compared to high‐end desktop CPUs. The acceleration of key data‐processing stages will decrease the time needed to perform image‐guided patient positioning and analysis. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2634 / 2634
页数:1
相关论文
共 50 条
  • [1] GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration
    Sharp, G. C.
    Kandasamy, N.
    Singh, H.
    Folkert, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5771 - 5783
  • [2] Deformable image registration of CT and truncated cone-beam CT for adaptive radiation therapy
    Zhen, Xin
    Yan, Hao
    Zhou, Linghong
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22): : 7979 - 7993
  • [3] Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration
    Kearney, V.
    Gu, X.
    Chen, S.
    Jiang, L.
    Liu, H.
    Chiu, T.
    Yordy, J.
    Nedzi, L.
    Mao, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 500 - 500
  • [4] Evaluation of a CT to cone-beam CT deformable registration algorithm
    Piper, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S418 - S419
  • [5] Effects of cone-beam CT noise and cupping artifacts on deformable image registration
    Murphy, M.
    Lu, L.
    Crimaldi, A.
    Cuttino, L.
    Shield, C.
    Keall, P.
    Siebers, J.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1996 - 1996
  • [6] Converting Cone-Beam CT to In-Room Conventional CT by a Deformable Image Registration Method
    Zhang, Y.
    Yang, J.
    Zhang, L.
    Dong, L.
    MEDICAL PHYSICS, 2009, 36 (06) : 2477 - +
  • [7] Deformable planning CT to cone-beam CT image registration in head-and-neck cancer
    Hou, Jidong
    Guerrero, Mariana
    Chen, Wenjuan
    D'Souza, Warren D.
    MEDICAL PHYSICS, 2011, 38 (04) : 2088 - 2094
  • [8] Deformable image registration in cone-beam CT images for image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Zhu, X.
    Garden, A.
    Ahamad, A.
    Ang, K.
    Mohan, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 1995 - 1995
  • [9] CT to Cone-Beam CT Deformable Registration With Simultaneous Intensity Correction
    Zhen, X.
    Yan, H.
    Gu, X.
    Zhou, L.
    Jia, X.
    Jiang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3960 - 3960
  • [10] CT to cone-beam CT deformable registration with simultaneous intensity correction
    Zhen, Xin
    Gu, Xuejun
    Yan, Hao
    Zhou, Linghong
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21): : 6807 - 6826