Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery

被引:34
|
作者
Mercier, Laurence [1 ]
Fonov, Vladimir [1 ]
Haegelen, Claire [1 ,2 ,3 ,4 ]
Del Maestro, Rolando F. [5 ]
Petrecca, Kevin [5 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, McConnell Brain Imaging Ctr, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
[2] Univ Rennes 1, INSERM, U746, Fac Med, Rennes, France
[3] Univ Rennes 1, INRIA, VisAGeSUnit Project, Rennes, France
[4] Univ Rennes 1, CNRS, UMR 6074, IRISA, Rennes, France
[5] McGill Univ, Brain Tumour Res Ctr, Montreal, PQ H3A 2B4, Canada
基金
加拿大健康研究院;
关键词
Intraoperative ultrasound; Brain tumors; Multimodal registration; Validation; VESSEL-BASED REGISTRATION; INTRAOPERATIVE ULTRASOUND; GUIDED NEUROSURGERY; BRAIN-SHIFT; TUMOR RESECTION; 3-D ULTRASOUND; 3D ULTRASOUND; MR-IMAGES; VALIDATION; INFORMATION;
D O I
10.1007/s11548-011-0620-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose We present a new technique for registering magnetic resonance (MR) and ultrasound images in the context of neurosurgery. It involves generating a pseudo-ultrasound (pseudo-US) from a segmented MR image and uses cross-correlation as the cost function to register the pseudo-US to the real ultrasound data. The algorithm's performance is compared with that of a state-of-the-art technique that uses a median-filtered MR image to register to a Gaussian-blurred ultrasound using a normalized mutual information (NMI) objective function. Methods The two methods were tested on data from 15 patients with brain tumor, including low-and high-grade gliomas, in both first operations and reoperations. Two metrics were used to evaluate registration accuracy: (1) the mean distance between corresponding points, identified on both MR and ultrasound images by two experts, and (2) ratings based on visual comparison by one neurosurgeon. Results The mean residual distance of the pseudo-US technique, 2.97mm, is significantly more accurate (p =. 0011) than that of the NMI approach, 4.86mm. The visual assessment shows that only 4 of the 15 cases had a satisfactory initial alignment based on homologous skin-point registration. There is a significant correlation between the quantitative distance measures and the qualitative ratings (rho=0.785). Conclusion The results show that the pseudo-US rigid registration technique robustly improves the MRI-ultrasound alignment when compared with the initial alignment, even when applied to highly distorted brains and a large range of tumor sizes and appearances.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 50 条
  • [41] Detection of suspected malignant patterns in three-dimensional magnetic resonance breast images
    Essam A. El-Kwae
    Joel E. Fishman
    Maria J. Bianchi
    Pradip M. Pattany
    Mansur R. Kabuka
    Journal of Digital Imaging, 1998, 11
  • [42] Estimation of Tendon Moment Arms from Three-Dimensional Magnetic Resonance Images
    Wilson, David L.
    Zhu, Qian
    Duerk, Jeffrey L.
    Mansour, Joseph M.
    Kilgore, Kevin
    Crago, Patrick E.
    Annals of Biomedical Engineering, 27 (02): : 247 - 256
  • [43] Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
    Division of Radiological Sciences, U. Med. Dent. Schools Guy's St. T., Guy's Hospital, London Bridge, London, SE1 9RT, United Kingdom
    MED. PHYS., 1 (25-35):
  • [44] Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
    Studholme, C
    Hill, DLG
    Hawkes, DJ
    MEDICAL PHYSICS, 1997, 24 (01) : 25 - 35
  • [45] Estimation of Tendon Moment Arms from Three-Dimensional Magnetic Resonance Images
    David L. Wilson
    Qian Zhu
    Jeffrey L. Duerk
    Joseph M. Mansour
    Kevin Kilgore
    Patrick E. Crago
    Annals of Biomedical Engineering, 1999, 27 : 247 - 256
  • [46] A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images
    Mahfouz, MR
    Hoff, WA
    Komistek, RD
    Dennis, DA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (12) : 1561 - 1574
  • [47] NEAR REAL-TIME ROBUST NON-RIGID REGISTRATION OF VOLUMETRIC ULTRASOUND IMAGES FOR NEUROSURGERY
    Rivaz, Hassan
    Collins, D. Louis
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (02): : 574 - 587
  • [48] Development of fetal brain sulci and gyri: assessment through two and three-dimensional ultrasound and magnetic resonance imaging
    Rolo, Liliam Cristine
    Araujo, Edward, Jr.
    Machado Nardozza, Luciano Marcondes
    de Oliveira, Patricia Soares
    Ajzen, Sergio Aron
    Moron, Antonio Fernandes
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2011, 283 (02) : 149 - 158
  • [49] Development of fetal brain sulci and gyri: assessment through two and three-dimensional ultrasound and magnetic resonance imaging
    Liliam Cristine Rolo
    Edward Araujo
    Luciano Marcondes Machado Nardozza
    Patrícia Soares de Oliveira
    Sérgio Aron Ajzen
    Antonio Fernandes Moron
    Archives of Gynecology and Obstetrics, 2011, 283 : 149 - 158
  • [50] Agreement of two-dimensional and three-dimensional transvaginal ultrasound with magnetic resonance imaging in assessment of parametrial infiltration in cervical cancer
    Chiappa, V.
    Di Legge, A.
    Valentini, A. L.
    Gui, B.
    Micco, M.
    Ludovisi, M.
    Giansiracusa, C.
    Testa, A. C.
    Valentin, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (04) : 459 - 469