Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery

被引:34
|
作者
Mercier, Laurence [1 ]
Fonov, Vladimir [1 ]
Haegelen, Claire [1 ,2 ,3 ,4 ]
Del Maestro, Rolando F. [5 ]
Petrecca, Kevin [5 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, McConnell Brain Imaging Ctr, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
[2] Univ Rennes 1, INSERM, U746, Fac Med, Rennes, France
[3] Univ Rennes 1, INRIA, VisAGeSUnit Project, Rennes, France
[4] Univ Rennes 1, CNRS, UMR 6074, IRISA, Rennes, France
[5] McGill Univ, Brain Tumour Res Ctr, Montreal, PQ H3A 2B4, Canada
基金
加拿大健康研究院;
关键词
Intraoperative ultrasound; Brain tumors; Multimodal registration; Validation; VESSEL-BASED REGISTRATION; INTRAOPERATIVE ULTRASOUND; GUIDED NEUROSURGERY; BRAIN-SHIFT; TUMOR RESECTION; 3-D ULTRASOUND; 3D ULTRASOUND; MR-IMAGES; VALIDATION; INFORMATION;
D O I
10.1007/s11548-011-0620-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose We present a new technique for registering magnetic resonance (MR) and ultrasound images in the context of neurosurgery. It involves generating a pseudo-ultrasound (pseudo-US) from a segmented MR image and uses cross-correlation as the cost function to register the pseudo-US to the real ultrasound data. The algorithm's performance is compared with that of a state-of-the-art technique that uses a median-filtered MR image to register to a Gaussian-blurred ultrasound using a normalized mutual information (NMI) objective function. Methods The two methods were tested on data from 15 patients with brain tumor, including low-and high-grade gliomas, in both first operations and reoperations. Two metrics were used to evaluate registration accuracy: (1) the mean distance between corresponding points, identified on both MR and ultrasound images by two experts, and (2) ratings based on visual comparison by one neurosurgeon. Results The mean residual distance of the pseudo-US technique, 2.97mm, is significantly more accurate (p =. 0011) than that of the NMI approach, 4.86mm. The visual assessment shows that only 4 of the 15 cases had a satisfactory initial alignment based on homologous skin-point registration. There is a significant correlation between the quantitative distance measures and the qualitative ratings (rho=0.785). Conclusion The results show that the pseudo-US rigid registration technique robustly improves the MRI-ultrasound alignment when compared with the initial alignment, even when applied to highly distorted brains and a large range of tumor sizes and appearances.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 50 条
  • [21] Rigid Registration of 3D Ultrasound and MRI: Comparing Two Approaches on Nine Tumor Cases
    Mercier, Laurence
    Fonov, Vladimir
    Del Maestro, Rolando F.
    Petrecca, Kevin
    Ostergaard, Lasse R.
    Collins, D. Louis
    BRAIN, BODY AND MACHINE, 2010, 83 : 33 - +
  • [22] Registration of cardiac magnetic resonance images with three-dimensional electroanatomical mapping to guide catheter ablation in the left ventricle
    Reddy, VY
    Malchano, ZJ
    Holmvang, G
    Schmidt, EJ
    Houghtaling, C
    Chan, RC
    Ruskin, JN
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 130A - 130A
  • [23] Three-Dimensional Registration of Freehand-Tracked Ultrasound to CT Images of the Talocrural Joint
    Tumer, Nazli
    Kok, Aimee C.
    Vos, Frans M.
    Streekstra, Geert J.
    Askeland, Christian
    Tuijthof, Gabrielle J. M.
    Zadpoor, Amir A.
    SENSORS, 2018, 18 (07)
  • [24] An adaptive fuzzy segmentation algorithm for three-dimensional magnetic resonance images
    Pham, DL
    Prince, JL
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 1999, 1613 : 140 - 153
  • [25] Unsupervised algorithm for the segmentation of three-dimensional magnetic resonance brain images
    Capelle, AS
    Alata, O
    Fernandez-Maloigne, C
    Ferrie, JC
    2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL III, PROCEEDINGS, 2001, : 1047 - 1050
  • [26] Quantification of regional deformation of the lungs by non-rigid registration of three-dimensional contrast-enhanced magnetic resonance imaging
    Shao, Jiaxin
    Hu, Peng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2017, 7 (02) : 177 - 186
  • [27] Combination of ultrasound, magnetic resonance imaging and virtual reality technologies to generate immersive three-dimensional fetal images
    Werner, H.
    Lopes Dos Santos, J. R.
    Ribeiro, G.
    Belmonte, S. L.
    Daltro, P.
    Araujo Junior, E.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 50 (02) : 271 - +
  • [28] Semiautomatic three-dimensional segmentation of the prostate using two-dimensional ultrasound images
    Wang, YQ
    Cardinal, HN
    Downey, DB
    Fenster, A
    MEDICAL PHYSICS, 2003, 30 (05) : 887 - 897
  • [29] Three-dimensional registration and analysis for brain SPECT images
    Liao, YL
    Sun, YN
    Chiu, NT
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2715 - 2719
  • [30] Elastic & efficient three-dimensional registration for abdominal images
    Wang, XiuYing
    Ballangan, Cherry
    Feng, David
    ISDA 2006: SIXTH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND APPLICATIONS, VOL 2, 2006, : 502 - +