Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery

被引:34
|
作者
Mercier, Laurence [1 ]
Fonov, Vladimir [1 ]
Haegelen, Claire [1 ,2 ,3 ,4 ]
Del Maestro, Rolando F. [5 ]
Petrecca, Kevin [5 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, McConnell Brain Imaging Ctr, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
[2] Univ Rennes 1, INSERM, U746, Fac Med, Rennes, France
[3] Univ Rennes 1, INRIA, VisAGeSUnit Project, Rennes, France
[4] Univ Rennes 1, CNRS, UMR 6074, IRISA, Rennes, France
[5] McGill Univ, Brain Tumour Res Ctr, Montreal, PQ H3A 2B4, Canada
基金
加拿大健康研究院;
关键词
Intraoperative ultrasound; Brain tumors; Multimodal registration; Validation; VESSEL-BASED REGISTRATION; INTRAOPERATIVE ULTRASOUND; GUIDED NEUROSURGERY; BRAIN-SHIFT; TUMOR RESECTION; 3-D ULTRASOUND; 3D ULTRASOUND; MR-IMAGES; VALIDATION; INFORMATION;
D O I
10.1007/s11548-011-0620-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose We present a new technique for registering magnetic resonance (MR) and ultrasound images in the context of neurosurgery. It involves generating a pseudo-ultrasound (pseudo-US) from a segmented MR image and uses cross-correlation as the cost function to register the pseudo-US to the real ultrasound data. The algorithm's performance is compared with that of a state-of-the-art technique that uses a median-filtered MR image to register to a Gaussian-blurred ultrasound using a normalized mutual information (NMI) objective function. Methods The two methods were tested on data from 15 patients with brain tumor, including low-and high-grade gliomas, in both first operations and reoperations. Two metrics were used to evaluate registration accuracy: (1) the mean distance between corresponding points, identified on both MR and ultrasound images by two experts, and (2) ratings based on visual comparison by one neurosurgeon. Results The mean residual distance of the pseudo-US technique, 2.97mm, is significantly more accurate (p =. 0011) than that of the NMI approach, 4.86mm. The visual assessment shows that only 4 of the 15 cases had a satisfactory initial alignment based on homologous skin-point registration. There is a significant correlation between the quantitative distance measures and the qualitative ratings (rho=0.785). Conclusion The results show that the pseudo-US rigid registration technique robustly improves the MRI-ultrasound alignment when compared with the initial alignment, even when applied to highly distorted brains and a large range of tumor sizes and appearances.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 50 条
  • [1] Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery
    Laurence Mercier
    Vladimir Fonov
    Claire Haegelen
    Rolando F. Del Maestro
    Kevin Petrecca
    D. Louis Collins
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 125 - 136
  • [2] Nonrigid registration of three-dimensional ultrasound and magnetic resonance images of the carotid arteries
    Nanayakkara, Nuwan D.
    Chiu, Bernard
    Samani, Abbas
    Spence, J. David
    Samarabandu, Jagath
    Parraga, Grace
    Fenster, Aaron
    MEDICAL PHYSICS, 2009, 36 (02) : 373 - 385
  • [3] Registration of three-dimensional magnetic resonance and radionuclide skeletal images
    Wong, TZ
    Connolly, LP
    Treves, ST
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (11) : 859 - 863
  • [4] Three-dimensional registration of prostate images from histology and ultrasound
    Taylor, LS
    Porter, BC
    Nadasdy, G
    Di Sant'Agnese, PA
    Pasternack, D
    Wu, Z
    Baggs, RB
    Rubenst, DJ
    Parker, KJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (02): : 161 - 168
  • [5] Three-dimensional frameless fusion of color Doppler ultrasound and magnetic resonance images of the liver
    Rubens, DJ
    Strang, JG
    Porter, B
    Taylor, LS
    Parker, KJ
    RADIOLOGY, 1998, 209P : 265 - 266
  • [6] Global optimization of mutual information: application to three-dimensional retrospective registration of magnetic resonance images
    He, RJ
    Narayana, PA
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (04) : 277 - 292
  • [7] Registration and visualization of three-dimensional magnetic resonance (MR) and positron emission tomography (PET) images
    Gershon, Nahum D.
    Annals of Biomedical Engineering, 1991, 19 (05)
  • [8] Accurate three-dimensional registration of magnetic resonance images for detecting local changes in cartilage thickness
    Cheng, Yuanzhi
    Jin, Quan
    Zhao, Jie
    Guo, Changyong
    Bai, Jing
    JOURNAL OF ELECTRONIC IMAGING, 2011, 20 (02)
  • [9] Non-rigid registration of three-dimensional (3D) grayscale and Doppler ultrasound breast images
    Narayanasamy, Ganesh
    LeCarpentier, Gerald L.
    Zabuawala, Sakina
    Fowlkes, J. Brian
    Roubidoux, Marilyn
    Sinha, Sumedha
    Carson, Paul L.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 91 - 94
  • [10] Assessment of Registration Accuracy in Three-Dimensional Transrectal Ultrasound Images of Prostates
    Karnik, V.
    Fenster, A.
    Bax, J.
    Cool, D.
    Gardi, L.
    Gyacskov, Igor
    Romagnoli, C.
    Ward, A. D.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625