Mechanical Assistance by Intra-Aortic Balloon Pump Counterpulsation During Reperfusion Increases Coronary Blood Flow and Mitigates the No-Reflow Phenomenon: An Experimental Study

被引:24
|
作者
Pierrakos, Charalampos N. [1 ]
Bonios, Michael J. [1 ]
Drakos, Stavros G. [1 ]
Charitos, Efstratios I. [1 ]
Tsolakis, Elias J. [1 ]
Ntalianis, Argirios [1 ]
Nanas, Serafim N. [2 ]
Charitos, Christos E. [3 ]
Nanas, John N. [1 ]
Terrovitis, John V. [1 ]
机构
[1] Univ Athens, Sch Med, Dept Cardiol 3, GR-11527 Athens, Greece
[2] Univ Athens, Sch Med, Dept Pulm & Crit Care Med, GR-11527 Athens, Greece
[3] Evangelismos Med Ctr, Dept Cardiac Surg 2, Athens, Greece
关键词
Myocardial infarction; Intra-aortic balloon pump; Coronary circulation; Blood flow; Reperfusion; ACUTE MYOCARDIAL-INFARCTION; CARDIOGENIC-SHOCK; MICROVASCULAR OBSTRUCTION; LEUKOCYTE ACCUMULATION; ISCHEMIA; SIZE; THROMBOLYSIS; SURVIVAL; INJURY; AUGMENTATION;
D O I
10.1111/j.1525-1594.2011.01241.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effects of the intra-aortic balloon pump (IABP) counterpulsation on the extent of myocardial infarction (MI), the no-reflow phenomenon (NRP), and coronary blood flow (CBF) during reperfusion in an ischemia-reperfusion experimental model have not been clarified. Eleven pigs underwent occlusion of the mid left anterior descending coronary artery for 1 h, followed by reperfusion for 2 h. CBF, distal to the occlusion site, was measured. In six experiments, IABP support began 10 min before, and continued throughout reperfusion (IABP Group). Five pigs without IABP support served as controls. At the end of each experiment, the myocardial area at risk (MAR) of infarction and the extent of MI and NRP were measured. Hemodynamic measurements at baseline and during coronary occlusion were similar in both groups. During reperfusion, systolic aortic blood pressure was significantly lower in the IABP Group than in controls. In the IABP Group, CBF reached a peak at 5 min of reperfusion, gradually decreased, but remained higher than at baseline, and significantly higher than in controls throughout the 2 h of reperfusion. In controls, CBF increased significantly above baseline immediately after the onset of reperfusion, then returned to baseline within 90 min. The extent of NRP (37 +/- 25% vs. 68 +/- 17%, P = 0.047) and MI (39 +/- 23% vs. 67 +/- 13%, P = 0.036), both expressed as percentage of MAR, was significantly less in the IABP group than in controls. After prolonged myocardial ischemia, IABP assistance started just 10 min before and throughout reperfusion increased CBF and limited infarct size and extent of NRP.
引用
收藏
页码:867 / 874
页数:8
相关论文
共 50 条
  • [21] THE EFFECT OF INTRA-AORTIC BALLOON COUNTERPULSATION COMBINED WITH PROPRANOLOL ADMINISTRATION ON CORONARY BLOOD-FLOW IN NORMAL AND ISCHEMIC MYOCARDIUM
    GABAUER, I
    NOSALOVA, V
    OKOLICANY, J
    TRNOVEC, T
    STYK, J
    HOLEC, V
    PHYSIOLOGIA BOHEMOSLOVACA, 1981, 30 (02): : 168 - 169
  • [22] Combined impella and intra-aortic balloon pump support to improve both ventricular unloading and coronary blood flow for myocardial recovery: An experimental study
    Sauren, Loes D. C.
    Accord, Ryan E.
    Hamzeh, Khaled
    de Jong, Monique
    van der Nagel, Theo
    van der Veen, Frederik H.
    Maessen, Jos G.
    ARTIFICIAL ORGANS, 2007, 31 (11) : 839 - 842
  • [23] Does intra-aortic balloon counterpulsation influence coronary blood flow velocity spectrum in patients with AMI without cardiogenic shock?
    Prunier, F
    Furber, A
    Delépine, S
    Geslin, P
    EUROPEAN HEART JOURNAL, 2001, 22 : 513 - 513
  • [24] SIMILARITIES BETWEEN EXTERNAL COUNTERPULSATION AND INTRA-AORTIC BALLOON PUMPING - INFLUENCE ON COLLATERAL CORONARY BLOOD-FLOW IN ISCHEMIC MYOCARDIUM
    SUGG, WL
    WATSON, JT
    PLATT, MR
    WILLERSO.JT
    CIRCULATION, 1974, 50 (04) : 69 - 69
  • [25] Comparison of coronary artery blood flow and hemodynamic energy in a pulsatile pump versus a combined nonpulsatile pump and an intra-aortic balloon pump
    Lim, Choon Hak
    Son, Ho Sung
    Baek, Kwang Je
    Lee, Jung Joo
    Ahn, Chi Bum
    Moon, Ki Chul
    Khi, Woong
    Lee, HyeWon
    Sun, Kyung
    ASAIO JOURNAL, 2006, 52 (05) : 595 - 597
  • [26] Short intra-aortic counterpulsation balloon prevents visceral hypoperfusion enhancing myocardial blood flow and hemodynamics in a porcine model of ischemia reperfusion
    Gelsomino, S.
    Luca, F.
    Rao, C. M.
    Lozekoot, P. W. J.
    Puntrello, C.
    Francese, G. M.
    Parise, O.
    De Jong, M. M. J.
    Narendra, K.
    Benedetto, F.
    Romano, M.
    Lorusso, R.
    Lameir, M.
    Gulizia, M. M.
    Maessen, J. G.
    EUROPEAN HEART JOURNAL, 2016, 37 : 372 - 373
  • [27] INCREASE OF NUTRIENT MYOCARDIAL BLOOD-FLOW BY INTRA-AORTIC BALLOON PUMPING IN EXPERIMENTAL CORONARY ISCHEMIA
    SAINI, VK
    WRIGHT, W
    BERGER, RL
    HECHTMAN, H
    HOOD, WB
    CIRCULATION, 1972, 46 (04) : 99 - &
  • [28] Effects of Intra-Aortic Balloon Pump on Coronary Artery Bypass Grafts Blood Flow: Differences by Graft Type and Coronary Target
    Onorati, Francesco
    Santini, Francesco
    Rubino, Antonino Salvatore
    Amoncelli, Enrico
    Gianbruno, Vincenzo
    Renzulli, Attilio
    Faggian, Giuseppe
    Mazzucco, Alessandro
    ARTIFICIAL ORGANS, 2011, 35 (09) : 849 - 856
  • [29] INTRA-AORTIC BALLOON COUNTERPULSATION - ITS INFLUENCE ALONE AND COMBINED WITH VARIOUS PHARMACOLOGICAL AGENTS ON REGIONAL MYOCARDIAL BLOOD-FLOW DURING EXPERIMENTAL ACUTE CORONARY-OCCLUSION
    JETT, GK
    DENGLE, SK
    BARNETT, PA
    PLATT, MR
    WILLERSON, JT
    WATSON, JT
    EBERHART, RC
    ANNALS OF THORACIC SURGERY, 1981, 31 (02): : 144 - 154
  • [30] Use of Intra-aortic Balloon Pump to Augment Treatment of No Reflow Phenomenon After Percutaneous Coronary Intervention of Non St Segment Elevation Myocardial Infarction
    Garber, V.
    Saad, P.
    Thomas, S.
    Hawatameh, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207