Effects of Intra-Aortic Balloon Pump on Coronary Artery Bypass Grafts Blood Flow: Differences by Graft Type and Coronary Target

被引:4
|
作者
Onorati, Francesco [1 ]
Santini, Francesco [1 ]
Rubino, Antonino Salvatore [2 ]
Amoncelli, Enrico [1 ]
Gianbruno, Vincenzo [1 ]
Renzulli, Attilio [2 ]
Faggian, Giuseppe [1 ]
Mazzucco, Alessandro [1 ]
机构
[1] Univ Verona, Div Cardiac Surg, Sch Med, I-37126 Verona, Italy
[2] Magna Graecia Univ Catanzaro, Cardiac Surg Unit, Catanzaro, Italy
关键词
Intra-aortic balloon pump; Perfusion; Coronary disease; Bypass grafts; Hemodynamics; RADIAL ARTERY; PROLIFERATION; PRESSURE; PATENCY;
D O I
10.1111/j.1525-1594.2011.01285.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The intra-aortic balloon pump (IABP) is used worldwide as an anti-ischemic strategy. However, little is known about the modifications of the graft blood flow during IABP. A retrospective study aimed at analyzing transit-time flow measurements during 1: 1 IABP and during its cessation in 401 consecutive patients receiving IABP before coronary artery bypass grafting (n = 880 graft segments) was reported. All normally functioning grafts were considered. Mean diastolic and mean blood flow improved significantly during 1: 1 IABP compared with during IABP cessation (P < 0.001), although mean and end-diastolic arterial pressures were significantly lower (P = 0.001). Arterial and sequential saphenous vein (SV) grafts showed greater improvements in mean diastolic and mean flow compared with single venous grafts. Higher flows were also observed in the grafts directed to the circumflex territory. Surplus graft flow (SGF, defined as mean flow during 1: 1 IABP/mean flow with IABP off) was recruited (SGF >1) during 1: 1 IABP, with higher values in single arterial or sequential SV grafts versus single venous grafts (both P < 0.001). Y-conduit radial artery (RA) grafts showed higher maximum diastolic flow, mean flow, and SGF compared to aortocoronary RA or SV grafts. In this retrospective analysis, IABP was associated with improved diastolic and mean blood flow in bypass grafts. Arterial, sequential, and Y-conduit grafts were associated with greater improvements in blood flow and SGF than aortocoronary SV grafts.
引用
收藏
页码:849 / 856
页数:8
相关论文
共 50 条
  • [1] The use of Intra Aortic Balloon Pump in Coronary Artery Bypass Graft Surgery
    Gunnarsdottir, Sunna Lu Xi
    Gunnarsdottir, Erla Liu Ting
    Heimisdottir, Alexandra Aldis
    Heidarsdottir, Sunna Run
    Helgadottir, Solveig
    Sigurdsson, Martin Ingi
    Gudbjartsson, Tomas
    LAEKNABLADID, 2020, 106 (02): : 63 - 70
  • [2] Transbrachial intra-aortic balloon pump before urgent coronary artery bypass graft in a patient with severe peripheral atherosclerosis
    Alvarez-Roy, Laura
    Benito-Gonzalez, Tomas
    Perez de Prado, Armando
    Gualis Cardona, Javier
    del Castillo, Samuel
    Fernandez-Vazquez, Felipe
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2018, 37 (02) : 205 - 207
  • [3] Characteristics, morbidity and mortality factors associated with Intra-Aortic Balloon Pump in Coronary Artery Bypass Graft Surgery patients
    Shah, Sayed Mumtaz Anwar
    Awan, Nabil, I
    Jan, Azam
    Rehman, Mujeeb Ur
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (06) : 1318 - 1324
  • [4] Predictors of Hospital Mortality in Coronary Artery Bypass Graft Surgery Patients Requiring Intra-Aortic Balloon Pump Support
    Chen-Scarabelli, Carol
    Faggian, Giuseppe
    Petrilli, Giuseppe
    Tessari, Maddalena
    Saravolatz, Louis
    Mazzucco, Alessandro
    Scarabelli, Tiziano M.
    CIRCULATION, 2010, 122 (21)
  • [5] Intra-aortic balloon pump placement in coronary artery bypass grafting patients by day of admission
    del Carmen, Gabriel A.
    Axtell, Andrea
    Chang, David
    Melnitchouk, Serguei
    Sundt, Thoralf M., III
    Fiedler, Amy G.
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)
  • [6] Intra-aortic balloon pump placement in coronary artery bypass grafting patients by day of admission
    Gabriel A. del Carmen
    Andrea Axtell
    David Chang
    Serguei Melnitchouk
    Thoralf M. Sundt
    Amy G. Fiedler
    Journal of Cardiothoracic Surgery, 15
  • [7] Analysis of clinical outcomes of intra-aortic balloon pump during coronary artery bypass surgery
    Yumun, Gunduz
    Aydin, Ufuk
    Ata, Yusuf
    Toktas, Faruk
    Pala, Arda Aybars
    Ozyazicioglu, Ahmet Fatih
    Turk, Tamer
    Yavuz, Senol
    CARDIOVASCULAR JOURNAL OF AFRICA, 2015, 26 (03) : 130 - 133
  • [8] Augmentation of coronary blood flow with intra-aortic balloon pump counter-pulsation
    O'Rourke, MF
    CIRCULATION, 2001, 103 (25) : E129 - E129
  • [9] The effect of intra-aortic balloon counterpulsation on coronary blood flow velocity distal to coronary artery stenoses
    Anderson, RD
    Gurbel, PA
    CARDIOLOGY, 1996, 87 (04) : 306 - 312
  • [10] Factors associated with pulmonary dysfunction in patients undergoing coronary artery bypass graft surgery with use of intra-aortic balloon pump
    Goncalves Fusatto, Helena Amaral
    de Figueiredo, Luciana Castilho
    Ragonete dos Anjos Agostini, Ana Paula
    Sibinelli, Melissa
    Dragosavac, Desanka