This paper deals with the limits of the resolution achievable in soft X-ray spectroscopy using silicon detectors of different dimensions (pad, pixel and drift detectors) operated at non-cryogenic temperatures. The role of the front-end electronics in achieving high resolution is examined with special care. It is found that in a common experimental setup the ultimate performance of the spectrometer is not limited by the thermal and shot white noises: the main contribution to the resolution performance arises from the non-white component of parallel noise due to the dielectric losses in the passive devices connected to the preamplifier input, especially when the detector leakage current is in the pA range. By using high quality feedback capacitors we have obtained significant improvements in the resolution performance. With a ceramic feedback capacitor and a commercial device as input transistor we have obtained at room temperature an Equivalent Noise Charge as low as 15 electrons rms (130 eV FWHM). We discuss the ultimate limits and the perspectives for room temperature operation of silicon soft X-ray detectors.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [31] Silicon drift detectors for exotic atomsApplication for kaonic X-ray spectroscopy
    T. Ishiwatari
    Hyperfine Interactions, 2009, 194 : 165 - 170
  • [32] Fundamental x-ray interaction limits in diagnostic imaging detectors: Spatial resolution
    Hajdok, G.
    Battista, J. J.
    Cunningham, I. A.
    MEDICAL PHYSICS, 2008, 35 (07) : 3180 - 3193
  • [33] X-ray irradiation of silicon detectors
    Chmill, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02): : 722 - 726
  • [34] Amorphous silicon X-ray detectors
    Hoheisel, M.
    Arques, M.
    Chabbal, J.
    Chaussat, C.
    Ducourant, T.
    Hahm, G.
    Horbaschek, H.
    Schulz, R.
    Spahn, M.
    Journal of Non-Crystalline Solids, 227-230 (Pt 2): : 1300 - 1305
  • [35] Amorphous silicon X-ray detectors
    Hoheisel, M
    Arques, M
    Chabbal, J
    Chaussat, C
    Ducourant, T
    Hahm, G
    Horbaschek, H
    Schulz, R
    Spahn, M
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 227 : 1300 - 1305
  • [36] Silicon Absolute X-Ray Detectors
    Seely, John F.
    Korde, Raj
    Sprunck, Jacob
    Medjoubi, Kadda
    Hustache, Stephanie
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 842 - +
  • [37] AREA DETECTORS FOR X-RAY SPECTROSCOPY
    CALLCOTT, TA
    TSANG, KL
    ZHANG, CH
    EDERER, DL
    ARAKAWA, ET
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 578 - 585
  • [38] Diamond detectors for x-ray spectroscopy
    Allegrini, P.
    Girolami, M.
    Calvani, P.
    Conte, G.
    Salvatori, S.
    Spiriti, E.
    Ralchenko, V.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS III, 2008, 7077
  • [39] Discrete analog electronics for high-resistivity silicon detectors used for x-ray and γ-ray spectroscopy in whole-body monitoring
    Inst de Protection et de Surete, Nucleaire, Fontenay-aux-Roses, France
    Nucl Instrum Methods Phys Res Sect A, 1-2 (371-375):
  • [40] High-resolution X-ray diffraction of silicon at low temperatures
    Lu, Z.
    Munakata, K.
    Kohno, A.
    Soejima, Y.
    Nuovo Cimento Della Societa Italiana Di Fisica. D, Condensed Matter, Atomic, Molecular and Chemical Physics, Biophysics, 19 (2-4):