Resolution limits of silicon detectors and electronics for soft X-ray spectroscopy at non cryogenic temperatures

被引:27
|
作者
Pullia, A
Bertuccio, G
机构
[1] Dipto. di Elettronica e Informazione, Politecnico di Milano, 20133, Milano
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1996年 / 380卷 / 1-2期
关键词
D O I
10.1016/S0168-9002(96)00476-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper deals with the limits of the resolution achievable in soft X-ray spectroscopy using silicon detectors of different dimensions (pad, pixel and drift detectors) operated at non-cryogenic temperatures. The role of the front-end electronics in achieving high resolution is examined with special care. It is found that in a common experimental setup the ultimate performance of the spectrometer is not limited by the thermal and shot white noises: the main contribution to the resolution performance arises from the non-white component of parallel noise due to the dielectric losses in the passive devices connected to the preamplifier input, especially when the detector leakage current is in the pA range. By using high quality feedback capacitors we have obtained significant improvements in the resolution performance. With a ceramic feedback capacitor and a commercial device as input transistor we have obtained at room temperature an Equivalent Noise Charge as low as 15 electrons rms (130 eV FWHM). We discuss the ultimate limits and the perspectives for room temperature operation of silicon soft X-ray detectors.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] Fundamental spatial resolution limits in existing diagnostic x-ray detectors
    Hajdok, G
    Cunningham, I
    MEDICAL PHYSICS, 2003, 30 (07) : 1947 - 1947
  • [22] Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector
    Chen, Er-Lei
    Feng, Chang-Qing
    Liu, Shu-Bin
    Ye, Chun-Feng
    Jin, Dong-Dong
    Lian, Jian
    Hu, Hui-Jun
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (01)
  • [23] Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector
    Er-Lei Chen
    Chang-Qing Feng
    Shu-Bin Liu
    Chun-Feng Ye
    Dong-Dong Jin
    Jian Lian
    Hui-Jun Hu
    Nuclear Science and Techniques, 2017, 28
  • [24] Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector
    Er-Lei Chen
    Chang-Qing Feng
    Shu-Bin Liu
    Chun-Feng Ye
    Dong-Dong Jin
    Jian Lian
    Hui-Jun Hu
    Nuclear Science and Techniques, 2017, 28 (01) : 69 - 74
  • [25] Cryogenic X-ray detectors for synchrotron science
    Friedrich, S
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 159 - 171
  • [26] An Automated System for Testing Readout Electronics of Silicon Strip X-ray Detectors
    Maj, Piotr
    Goral, Adrian
    Grybos, Pawel
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1060 - 1068
  • [27] Soft x-ray quantum efficiency of Silicon hybrid CMOS detectors
    Prieskorn, Zachary R.
    Bongiorno, Stephen D.
    Burrows, David N.
    Falcone, Abraham D.
    Griffith, Christopher V.
    Nikoleyczik, Jonathan
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VI, 2014, 9154
  • [28] Silicon photodiode soft x-ray detectors for pulsed power experiments
    Idzorek, GC
    Bartlett, RJ
    11TH IEEE INTERNATIONAL PULSED POWER CONFERENCE - DIGEST OF TECHNICAL PAPERS, VOLS. 1 & 2, 1997, : 1274 - 1279
  • [29] Microcalorimeter arrays for high resolution soft X-ray spectroscopy
    Stahle, CK
    Kelley, RL
    McCammon, D
    Moseley, SH
    Szymkowiak, AE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (01): : 173 - 176
  • [30] SEMICONDUCTOR DRIFT DETECTORS FOR HIGH-RESOLUTION X-RAY SPECTROSCOPY
    CASTOLDI, A
    SAMPIETRO, M
    SENSORS AND ACTUATORS A-PHYSICAL, 1992, 31 (1-3) : 245 - 249