Monte Carlo simulations for the characterization of position-sensitive x-ray detectors dedicated to Compton polarimetry

被引:16
|
作者
Weber, G. [1 ,2 ]
Braeuning, H. [1 ]
Maertin, R. [1 ,3 ]
Spillmann, U. [1 ]
Stoehlker, Th [1 ,2 ,3 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, D-64921 Darmstadt, Germany
[2] Helmholtz Inst Jena, D-07743 Jena, Germany
[3] Univ Heidelberg, Inst Phys, D-69120 Heidelberg, Germany
关键词
PHOTONS;
D O I
10.1088/0031-8949/2011/T144/014034
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We present here a Monte Carlo program based on the EGS5 package for modeling the detector response of position-sensitive x-ray detectors. The program is used to estimate the polarimeter quality of two novel detector systems applied in Compton polarimetry. The validity of the underlying physical models is verified by comparing the simulation output to experimental data obtained at the experimental storage ring, ESR.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] POSITION-SENSITIVE X-RAY DETECTOR.
    Duval, B.P.
    Barth, J.
    Deslattes, R.D.
    Henins, A.
    Luther, G.G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1983, 222 (1-2) : 274 - 278
  • [22] Characterization of X-ray Detectors in the MIT X-ray Polarimetry Beamline
    Heine, Sarah N. T.
    Marshall, Herman L.
    Schneider, Benjamin
    LaMarr, Beverly
    Kothnur, Nithya
    Garner, Alan
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY XI, 2024, 13103
  • [23] Performance of a position sensitive Si(Li) x-ray detector dedicated to Compton polarimetry of stored and trapped highly-charged ions
    Weber, G.
    Braeuning, H.
    Hess, S.
    Maertin, R.
    Spillmann, U.
    Stoehlker, Th
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [24] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [25] Improving the energy resolution of bent crystal X-ray spectrometers with position-sensitive detectors
    Honkanen, Ari-Pekka
    Verbeni, Roberto
    Simonelli, Laura
    Sala, Marco Moretti
    Al-Zein, Ali
    Krisch, Michael
    Monaco, Giulio
    Huotari, Simo
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 762 - 767
  • [26] OBSERVATION OF X-RAY RAMAN, COMPTON AND PLASMON SCATTERING USING A POSITION-SENSITIVE PROPORTIONAL COUNTER
    PATTISON, P
    BLEIF, HJ
    SCHNEIDER, JR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (01): : 95 - 99
  • [27] ENERGY RESOLUTIONS OF A POSITION-SENSITIVE NAI DETECTOR BY MONTE-CARLO SIMULATIONS
    TANG, SM
    HSU, HH
    SIMMONS, JE
    KAPUSTINSKY, J
    PENG, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 254 (01): : 129 - 134
  • [28] ENERGY RESOLUTIONS OF A POSITION-SENSITIVE NaI DETECTOR BY MONTE CARLO SIMULATIONS.
    Tang, S.M.
    Hsu, H.H.
    Simmons, J.E.
    Kapustinsky, J.
    Peng, J.C.
    Nuclear instruments and methods in physics research, 1987, A254 (01): : 129 - 134
  • [29] Optimised filtering for improved energy and position resolution in position-sensitive TES based X-ray detectors
    Smith, SJ
    Whitford, CH
    Fraser, GW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01): : 237 - 245
  • [30] Monte Carlo simulations in X-ray imaging
    Giersch, Juergen
    Durst, Juergen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 300 - 305