A study of atypical APTT derivative curves on the ACL TOP coagulation analyser

被引:40
|
作者
Solano, C. [1 ]
Zerafa, P. [1 ]
Bird, R. [1 ]
机构
[1] Princess Alexandra Hosp, Dept Haematol, Clin & Statewide Serv Div, Queensland Hlth, Brisbane, Qld 4102, Australia
关键词
Activated partial thromboplastin time; clot reaction curve; second derivative; first derivative; WAVE-FORM ANALYSIS; DISSEMINATED INTRAVASCULAR COAGULATION; HEMOPHILIA-A; DISORDERS; DIAGNOSIS;
D O I
10.1111/j.1751-553X.2010.01248.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P>Introduction: The graphical representation of clotting data can provide useful information. A novel feature of the ACL TOP software allows display of clot reaction curves with superimposed first and second derivative curves. We noted atypical derivative plots associated with normal 'S'-shaped clot reaction curves in some abnormal activated partial thromboplastin time (APTT). Methods: We tested 179 citrate plasmas with four different APTT reagents on the ACL TOP. We documented the prevalence and utility of these APTT atypical derivative curves in these patients. Results: Ellagic acid APTT reagents commonly produce atypical derivative curves despite normal 'S'-shaped clot reaction curves. Occasionally, these atypical second derivative curves may cause incorrect APTT results. With silica activator APTT reagents, atypical derivative curves were associated with genuine coagulation abnormalities such as single factor deficiencies and lupus anticoagulants (LAs). To our knowledge, this novel finding has not been reported. Conclusion: Atypical derivative curves seen in ellagic acid APTTs are of limited diagnostic use because of the frequency with which they occur. This may be related to the need to optimize the data reduction utilized on the ACL TOP for these reagents. With silica activator APTTs, the presence of atypical derivative curves proved to be a very simple tool when troubleshooting unexpected abnormal APTT results, commonly predicting a factor deficiency or LA that would warrant further investigation. The cause of these aberrant derivative curves is probably related to abnormal thrombin generation in the APTT test and warrants further study.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 43 条
  • [21] Analytical Performance of Modified Anti-FXa Assays for Andexanet Alfa-Containing Plasma Samples on the ACL TOP/TOP 50 Coagulation Analyzers
    Khan, Anuja
    Shishko, Krisjela
    Marett, Ryan
    Arcidiacono, Sam
    Vy Nguyen
    Lu, Genmin
    Bui, Khanh
    Conley, Pamela B.
    Winkler, Anne
    BLOOD, 2020, 136
  • [22] Measurement uncertainty of coagulation assays using the ACL TOP 750 CTS and the Stago STA Compact haemostasis testing systems
    Kim, H. R.
    Lim, Y. K.
    Cho, S. R.
    Ahn, J.
    CLINICA CHIMICA ACTA, 2019, 493 : S408 - S408
  • [23] Verification of the ACL Top 50 Family (350, 550, and 750) for Harmonization of Routine Coagulation Assays in a Large Network of 60 Laboratories
    Favaloro, Emmanuel J.
    Mohammed, Soma
    Vong, Ronny
    McVicker, Wendy
    Chapman, Kent
    Swanepoel, Priscilla
    Kershaw, Geoff
    Cai, Nancy
    Just, Sarah
    Connelly, Lynne
    Prasad, Ritam
    Brighton, Timothy
    Pasalic, Leonardo
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2021, 156 (04) : 661 - 678
  • [24] EVALUATION OF ACTIVATED PARTIAL THROMBOPLASTIN TIME COAGULATION WAVEFORMS GENERATED BY ACL TOP SERIES COAGULATION ANALYZERS CAN HELP IDENTIFY PATIENTS WITH ACQUIRED FACTOR VIII INHIBITORS.
    McGinnis, Eric
    Wong, Steven K. W.
    Smith, Tyler W.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 114 - 115
  • [25] Numerical study of a quasi 3D top-hat solar wind plasma analyser
    D'Amicis, R
    Bruno, R
    Bavassano, B
    Cattaneo, MB
    Baldetti, P
    Pallocchia, G
    SOLAR ENCOUNTER, 2001, 493 : 205 - 209
  • [26] Knee performance and self-efficacy trajectory curves after ACL reconstruction: A longitudinal study
    Pua, Yong-Hao
    Low, Juanita
    Woon, Ee-Lin
    Tay, Olivia Shi-Min
    Cheong, Philip
    Thumboo, Julian
    Clark, Ross Allan
    Chang, Paul
    Tan, Andrew
    Ho, Jia-Ying
    PHYSICAL THERAPY IN SPORT, 2021, 49 : 157 - 163
  • [27] Precision and accuracy study of a table top coagulation analyzer with expanded test menu
    Porche-Sorbet, R.
    Hughes, J.
    Barnes, P.
    Cutsforth, G.
    Whelchel, K.
    Eby, C. S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 1091 - 1091
  • [28] IDENTIFYING FACTOR DEFICIENCY WITH THE COAGPIA® APTT FS REAGENT AND THE AUTOMATED MIXING STUDY APPLICATION OF THE CP3000 COAGULATION SYSTEM
    Harper, Sarah
    Baker, Peter
    Smith, Larry
    Lakos, Gabriella
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 71 - 71
  • [29] Female Collegiate Soccer Player With Atypical Healing Following ACL Reconstruction: A Level 3 Case Study
    Pyne, Jessica
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 920 - 920
  • [30] Retrospective comparison of standard clotting tests and novel clot waveform parameters in dogs using the turbidimetric ACL-TOP CTS 300 coagulation analyzer
    Yagneswar, Hamsini
    Todd, Jeffrey M.
    Sharkey, Leslie C.
    Rendahl, Aaron
    Tart, Kelly
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2018, 30 (06) : 868 - 877