Intra-session repeatability of anterior chamber depth across the chamber width using Pentacam Scheimpflug imaging in healthy subjects

被引:3
|
作者
Phu, Jack [1 ,2 ]
Tong, Janelle [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
机构
[1] Univ New South Wales, Ctr Eye Hlth, Kensington, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Kensington, NSW, Australia
关键词
angle closure; angle closure disease; glaucoma; narrow angles; Pentacam; Scheimpflug imaging; OPTICAL COHERENCE TOMOGRAPHY; PATTERN-RECOGNITION ANALYSIS; ANGLE-CLOSURE; CORNEAL; AGREEMENT; VALIDITY; AGE;
D O I
10.1111/opo.12880
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Despite the importance of anterior chamber depth (ACD) measurements in disease and ageing, the repeatability and their threshold for change is not known. Our purpose was to determine the intra-session repeatability of Pentacam Scheimpflug photography for measuring the ACD across the chamber width in healthy subjects and thus inform expected limits of normality. Methods Pentacam Scheimpflug photography was used to obtain ACD measurements at 57 points across the central 8mm of the chamber width from one randomly selected eye of 130 healthy (normal vision and no ocular diseases, except age-normal cataracts) subjects (median age 58.0 years, interquartile range 46.3-63.0 years; 48 males, 82 females). Intra-session ACD measurements were compared. Univariate and multivariate linear regression was performed to identify categorical and continuous variables demonstrating a significant relationship with ACD and its repeatability. Results Bland-Altman analyses showed no directional or depth-dependent bias in the difference between the first and second tests (mean bias -0.003 mm, 95% limits of agreement -0.115 to +0.109 mm). Multivariate analysis found gender to be a significant factor (p < 0.0001), but not age (p = 0.69) nor ethnicity (p = 0.65), although the model fit was poor (R-2 = 0.004). There were no regional differences in repeatability measures found in males, but six locations in the superior aspect in females were found to be significantly different in their repeatability characteristics. Tolerance limits used to calculate the number of step sizes between 60-year-old age groups found 8.1-11.5 steps for females, and 7.5-9.2 steps for males. Conclusions Scheimpflug imaging using the Pentacam has excellent intra-session repeatability. Only gender appeared to affect repeatability characteristics, manifesting with a greater number of meaningful steps of change between two extremes of age range in females compared to males, which provides guidance for identifying clinically significant and measurable change between tests.
引用
收藏
页码:1273 / 1284
页数:12
相关论文
共 47 条
  • [41] Agreement between peripheral anterior chamber depth evaluation using the van Herick technique and angle width evaluation using the Shaffer system in Japanese
    Kashiwagi, K
    Tokunaga, T
    Iwase, A
    Yamamoto, T
    Tsukahara, S
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2005, 49 (02) : 134 - 136
  • [42] Agreement between peripheral anterior chamber depth evaluation using the van Herick technique and angle width evaluation using the Shaffer system in Japanese
    Kenji Kashiwagi
    Takaharu Tokunaga
    Aiko Iwase
    Tetsuya Yamamoto
    Shigeo Tsukahara
    Japanese Journal of Ophthalmology, 2005, 49 : 134 - 136
  • [43] Comparison of anterior chamber depth measurements by 3-dimensional optical coherence tomography, partial coherence interferometry biometry, Scheimpflug rotating camera imaging, and ultrasound biomicroscopy
    Nakakura, Shunsuke
    Mori, Etsuko
    Nagatomi, Nozomi
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1207 - 1213
  • [44] Repeatability of Manual Subfoveal Choroidal Thickness Measurements in Healthy Subjects Using the Technique of Enhanced Depth Imaging Optical Coherence Tomography
    Rahman, Waheeda
    Chen, Fred Kuanfu
    Yeoh, Jonathan
    Patel, Praveen
    Tufail, Adnan
    Da Cruz, Lyndon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2267 - 2271
  • [45] In vivo measurement of anterior chamber pulsation in healthy subjects using full-range complex spectral domain optical coherence tomography
    An, Lin
    Wu, Xiaocui
    Wang, Shuna
    He, Ke
    Chen, Yongran
    Lan, Gongpu
    Huang, Yanping
    Xu, Jingjiang
    Ou, Chubin
    Zeng, Xi
    Zhao, Yansong
    Wang, Xiaoli
    Long, Jinfeng
    Wei, Xunbin
    Qin, Jia
    OPTICS CONTINUUM, 2022, 1 (02): : 325 - 334
  • [46] Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation
    Doors, Muriel
    Cruysberg, Lars P. J.
    Berendschot, Tos T. J. M.
    de Brabander, John
    Verbakel, Frenne
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (08) : 1139 - 1146
  • [47] Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation
    Muriël Doors
    Lars P. J. Cruysberg
    Tos T. J. M. Berendschot
    John de Brabander
    Frenne Verbakel
    Carroll A. B. Webers
    Rudy M. M. A. Nuijts
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 1139 - 1146