Intra-session repeatability of anterior chamber depth across the chamber width using Pentacam Scheimpflug imaging in healthy subjects

被引:3
|
作者
Phu, Jack [1 ,2 ]
Tong, Janelle [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
机构
[1] Univ New South Wales, Ctr Eye Hlth, Kensington, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Kensington, NSW, Australia
关键词
angle closure; angle closure disease; glaucoma; narrow angles; Pentacam; Scheimpflug imaging; OPTICAL COHERENCE TOMOGRAPHY; PATTERN-RECOGNITION ANALYSIS; ANGLE-CLOSURE; CORNEAL; AGREEMENT; VALIDITY; AGE;
D O I
10.1111/opo.12880
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Despite the importance of anterior chamber depth (ACD) measurements in disease and ageing, the repeatability and their threshold for change is not known. Our purpose was to determine the intra-session repeatability of Pentacam Scheimpflug photography for measuring the ACD across the chamber width in healthy subjects and thus inform expected limits of normality. Methods Pentacam Scheimpflug photography was used to obtain ACD measurements at 57 points across the central 8mm of the chamber width from one randomly selected eye of 130 healthy (normal vision and no ocular diseases, except age-normal cataracts) subjects (median age 58.0 years, interquartile range 46.3-63.0 years; 48 males, 82 females). Intra-session ACD measurements were compared. Univariate and multivariate linear regression was performed to identify categorical and continuous variables demonstrating a significant relationship with ACD and its repeatability. Results Bland-Altman analyses showed no directional or depth-dependent bias in the difference between the first and second tests (mean bias -0.003 mm, 95% limits of agreement -0.115 to +0.109 mm). Multivariate analysis found gender to be a significant factor (p < 0.0001), but not age (p = 0.69) nor ethnicity (p = 0.65), although the model fit was poor (R-2 = 0.004). There were no regional differences in repeatability measures found in males, but six locations in the superior aspect in females were found to be significantly different in their repeatability characteristics. Tolerance limits used to calculate the number of step sizes between 60-year-old age groups found 8.1-11.5 steps for females, and 7.5-9.2 steps for males. Conclusions Scheimpflug imaging using the Pentacam has excellent intra-session repeatability. Only gender appeared to affect repeatability characteristics, manifesting with a greater number of meaningful steps of change between two extremes of age range in females compared to males, which provides guidance for identifying clinically significant and measurable change between tests.
引用
收藏
页码:1273 / 1284
页数:12
相关论文
共 47 条
  • [21] Intra-observer repeatability and interobserver agreement of the Smith method of measuring the anterior chamber depth
    Osuobeni, EP
    Oduwaiye, KA
    Ogbuehi, KC
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2000, 20 (02) : 153 - 159
  • [22] Anterior chamber parameters measured using the Pentacam Scheimpflug imaging device before and after cataract surgery in eyes with primary angle closure
    Omura, Tetsurou
    Tanito, Masaki
    Doi, Ryoko
    Ishida, Rina
    Ohira, Akihiro
    ACTA OPHTHALMOLOGICA, 2012, 90 (08) : e654 - e655
  • [23] Predicting postoperative anterior chamber depth in cataract patients using Scheimpflug slit photography
    Sasaki, H
    Sakamoto, Y
    Harada, S
    Sakamoto, A
    Kawakami, Y
    Nagai, K
    Takahashi, N
    Sasaki, K
    OPHTHALMIC RESEARCH, 2002, 34 (05) : 265 - 272
  • [24] Anterior Chamber Depth Measurements Obtained With Pentacam HR® Imaging System and Conventional A-scan Ultrasound
    Szalai, Eszter
    Berta, Andras
    Nemeth, Gabor
    Hassan, Ziad
    Modis, Laszlo
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (03) : 248 - 253
  • [25] Anterior Chamber and Aqueous Depth Measurement in Pseudophakic Eyes: Agreement Between Ultrasound Biometry and Scheimpflug Imaging
    Savini, Giacomo
    Hoffer, Kenneth J.
    Carbonelli, Michele
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (02) : 121 - 125
  • [26] Intra-session repeatability of quantitative metrics using widefield optical coherence tomography angiography (OCTA) in elderly subjects
    Hong, Jimmy
    Tan, Bingyao
    Quang, Nguyen Duc
    Gupta, Preeti
    Lin, Emily
    Wong, Damon
    Ang, Marcus
    Lamoureux, Ecosse
    Schmetterer, Leopold
    Chua, Jacqueline
    ACTA OPHTHALMOLOGICA, 2020, 98 (05) : E570 - E578
  • [27] Assessment and Comparison of Automated Anterior Chamber Metrics between Casia Swept-Source OCT vs Pentacam Scheimpflug Imaging
    Marion, Kenneth
    Dastiridou, Anna
    Francis, Brian
    Chopra, Vikas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [28] Anterior chamber depth and iridocorneal angle in healthy White subjects: effects of age, gender and refraction
    Ruefer, Florian
    Schroeder, Anke
    Klettner, Alexa
    Frimpong-Boateng, Adjoa
    Roider, Johann B.
    Erb, Carl
    ACTA OPHTHALMOLOGICA, 2010, 88 (08) : 885 - 890
  • [29] Scheimpflug vs Scanning-Slit Corneal Tomography: Comparison of Corneal and Anterior Chamber Tomography Indices for Repeatability and Agreement in Healthy Eyes
    Kanellopoulos, Anastasios John
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2583 - 2592
  • [30] Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and Pentacam
    Yazici, Ahmet Taylan
    Bozkurt, Ercument
    Alagoz, Cengiz
    Alagoz, Nese
    Pekel, Gokhan
    Kaya, Vedat
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) : 127 - 133