Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

被引:38
|
作者
Schutten, M.
Peters, D.
Back, N. K. T.
Beld, M.
Beuselinck, K.
Foulongne, V.
Geretti, A.-M.
Pandiani, L.
Tiemann, C.
Niesters, H. G. M.
机构
[1] Erasmus MC, Dept Virol, NL-3015 GD Rotterdam, Netherlands
[2] InnovirGrp Co, ZA-2047 Gardenview, South Africa
[3] Univ Amsterdam, Acad Med Ctr, Dept Med Microbiol, NL-1105 AZ Amsterdam, Netherlands
[4] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Lab Mol Diagnost, Louvain, Belgium
[5] Montpellier Univ Hosp, Virol Lab, F-34295 Montpellier, France
[6] UCL Royal Free Hosp, Dept Virol, London NW3 2PF, England
[7] UCL Royal Free & Univ Coll Med Sch, London NW3 2PF, England
[8] Labs Marcel Merieux, F-69357 Lyon 07, France
[9] Lab Dr Krone & Partner, LABCON OWL, Herford, Germany
关键词
D O I
10.1128/JCM.02385-06
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS TaqMan assays. Two different protocols used during the testing period with and without a pre-m1000 RNA isolation spin were compared. The difference proved to be nonsignificant. A uracil-N-glycosylase (UNG) contamination control option in the HCV test for previous Roche COBAS Amplicor users was evaluated. It proved to decrease amplicon carryover by 100-fold independent of the amplicon input concentration. The protocol including UNG proved to overcome problems with false-positive negative controls. Comparison with other assays revealed only minor differences. The largest difference was observed between the Abbott HCV RealTime assay and the Roche COBAS Amplicor HCV Monitor version 2.0 assay.
引用
收藏
页码:1712 / 1717
页数:6
相关论文
共 50 条
  • [41] Automated multiplex assay system for simultaneous detection of hepatitis B virus DNA, hepatitis C virus RNA, and human immuno deficiency virus type 1 RNA
    Meng, Q
    Wong, C
    Rangachari, A
    Tamatsukuri, S
    Sasaki, M
    Fiss, E
    Cheng, L
    Ramankutty, T
    Clarke, D
    Yawata, H
    Sakakura, Y
    Hirose, T
    Impraim, C
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (08) : 2937 - 2945
  • [42] In vitro human immunodeficiency virus type 1 integrase assays
    Marchand, C
    Neamati, N
    Pommier, Y
    DRUG-NUCLEIC ACID INTERACTIONS, 2001, 340 : 624 - 633
  • [43] Sensitivity of the procleix HIV-1/HCV assay for detection of human immunodeficiency virus type 1 and hepatitis C virus RNA in a high-risk population
    Jackson, JB
    Smith, K
    Knott, C
    Korpela, A
    Simmons, A
    Piwowar-Manning, E
    McDonough, S
    Mimms, L
    Vargo, JM
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (07) : 2387 - 2391
  • [44] Simultaneous detection of multiplex-amplified human immunodeficiency virus type 1 RNA, hepatitis C virus RNA, and hepatitis B virus DNA using a flow cytometer microsphere-based hybridization assay
    Defoort, JP
    Martin, M
    Casano, B
    Prato, S
    Camilla, C
    Fert, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (03) : 1066 - 1071
  • [45] Human immunodeficiency virus and hepatitis C virus coinfection
    Cacoub, P.
    Sene, D.
    Rosenthal, E.
    Pol, S.
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2008, 32 (03): : S82 - S89
  • [46] Multicenter evaluation of a new rapid automated human immunodeficiency virus antigen detection assay
    Weber, B
    Mühlbacher, A
    Michl, U
    Paggi, G
    Bossi, V
    Sargento, C
    Camacho, R
    Fall, EHMB
    Berger, A
    Schmitt, U
    Melchior, W
    JOURNAL OF VIROLOGICAL METHODS, 1999, 78 (1-2) : 61 - 70
  • [47] Evaluation of an automated sample preparation protocol for quantitative detection of hepatitis C virus RNA
    Stelzl, E
    Kormann-Klement, A
    Haas, J
    Daghofer, E
    Santner, BI
    Marth, E
    Kessler, HH
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (04) : 1447 - 1450
  • [48] Correlates of spontaneous clearance of hepatitis C virus in a Danish human immunodeficiency virus type 1 cohort
    Clausen, Louise Nygaard
    Weis, Nina
    Schonning, Kristian
    Fenger, Mogens
    Krarup, Henrik
    Bukh, Jens
    Benfield, Thomas
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2011, 43 (10) : 798 - 803
  • [49] Hepatitis C virus (HCV) and human immunodeficiency virus type 1 (HIV-1) infections in alcoholics
    Prakash, O
    Mason, A
    Luftig, RB
    Bautista, AP
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2002, 7 : E286 - E300
  • [50] Development of multiplexed nucleic acid testing for human immunodeficiency virus type 1 and hepatitis C virus
    Cleland, A
    Davis, C
    Adams, N
    Lycett, C
    Jarvis, LM
    Holmes, H
    Simmonds, P
    VOX SANGUINIS, 2001, 81 (02) : 93 - 101