Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

被引:38
|
作者
Schutten, M.
Peters, D.
Back, N. K. T.
Beld, M.
Beuselinck, K.
Foulongne, V.
Geretti, A.-M.
Pandiani, L.
Tiemann, C.
Niesters, H. G. M.
机构
[1] Erasmus MC, Dept Virol, NL-3015 GD Rotterdam, Netherlands
[2] InnovirGrp Co, ZA-2047 Gardenview, South Africa
[3] Univ Amsterdam, Acad Med Ctr, Dept Med Microbiol, NL-1105 AZ Amsterdam, Netherlands
[4] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Lab Mol Diagnost, Louvain, Belgium
[5] Montpellier Univ Hosp, Virol Lab, F-34295 Montpellier, France
[6] UCL Royal Free Hosp, Dept Virol, London NW3 2PF, England
[7] UCL Royal Free & Univ Coll Med Sch, London NW3 2PF, England
[8] Labs Marcel Merieux, F-69357 Lyon 07, France
[9] Lab Dr Krone & Partner, LABCON OWL, Herford, Germany
关键词
D O I
10.1128/JCM.02385-06
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS TaqMan assays. Two different protocols used during the testing period with and without a pre-m1000 RNA isolation spin were compared. The difference proved to be nonsignificant. A uracil-N-glycosylase (UNG) contamination control option in the HCV test for previous Roche COBAS Amplicor users was evaluated. It proved to decrease amplicon carryover by 100-fold independent of the amplicon input concentration. The protocol including UNG proved to overcome problems with false-positive negative controls. Comparison with other assays revealed only minor differences. The largest difference was observed between the Abbott HCV RealTime assay and the Roche COBAS Amplicor HCV Monitor version 2.0 assay.
引用
收藏
页码:1712 / 1717
页数:6
相关论文
共 50 条
  • [21] Mini review: Current molecular methods for the detection and quantification of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus type 1
    Albertoni, Guilherme
    Batista Castelo Girao, Manoel Joao
    Schor, Nestor
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2014, 25 : 145 - 149
  • [22] Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma
    Foulongne, Vincent
    Montes, Brigitte
    Didelot-Rousseau, Marie-Noelle
    Segondy, Michel
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (08) : 2963 - 2966
  • [23] Improved methods for quantification of human immunodeficiency virus type 1 RNA and hepatitis C virus RNA in blood using spin column technology and chemiluminescent assays of PCR products
    Lin, HJ
    Tanwandee, T
    Hollinger, FB
    JOURNAL OF MEDICAL VIROLOGY, 1997, 51 (01) : 56 - 63
  • [24] High prevalence of GB virus C/hepatitis G virus RNA and antibodies in patients infected with human immunodeficiency virus type 1
    Rey, D
    Vidinic-Moularde, J
    Meyer, P
    Schmitt, C
    Fritsch, S
    Lang, JM
    Stoll-Keller, F
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2000, 19 (09) : 721 - 724
  • [25] High Prevalence of GB Virus C/Hepatitis G Virus RNA and Antibodies in Patients Infected with Human Immunodeficiency Virus Type 1
    D. Rey
    J. Vidinic-Moularde
    P. Meyer
    C. Schmitt
    S. Fritsch
    J. M. Lang
    F. Stoll-Keller
    European Journal of Clinical Microbiology and Infectious Diseases, 2000, 19 : 721 - 724
  • [26] MULTICENTER EVALUATION OF QUANTIFICATION METHODS FOR PLASMA HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 RNA
    LIN, HJ
    MYERS, LE
    YENLIEBERMAN, B
    HOLLINGER, FB
    HENRARD, D
    HOOPER, CJ
    KOKKA, R
    KWOK, S
    RASHEED, S
    VAHEY, M
    WINTERS, MA
    MCQUAY, LJ
    NARA, PL
    REICHELDERFER, P
    COOMBS, RW
    JACKSON, JB
    JOURNAL OF INFECTIOUS DISEASES, 1994, 170 (03): : 553 - 562
  • [27] Multicenter evaluation of use of dried blood and plasma spot specimens in quantitative assays for human immunodeficiency virus RNA: Measurement, precision, and RNA stability
    Brambilla, D
    Jennings, C
    Aldrovandi, G
    Bremer, J
    Comeau, AM
    Cassol, SA
    Dickover, R
    Jackson, JB
    Pitt, J
    Sullivan, JL
    Butcher, A
    Grosso, L
    Reichelderfer, P
    Fiscus, SA
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) : 1888 - 1893
  • [28] Evaluation of three quantitative assays for hepatitis C virus.
    Oshita, M
    Hayashi, N
    Kasahara, A
    Hagiwara, H
    Yuki, N
    Takehara, T
    Katayama, K
    Sasaki, Y
    Fusamoto, H
    Kamada, T
    GASTROENTEROLOGY, 1996, 110 (04) : A1287 - A1287
  • [29] Multiplex Fluorescence Quantitative Polymerase Chain Reaction for Simultaneous Detection of Hepatitis B Virus, Hepatitis C Virus and Human Immunodeficiency Virus
    Tan, Bin
    Qin, Li
    Chen, ChunXia
    Huang, ChunYan
    Han, Bing
    Wang, LiXin
    Wei, ZengZhen
    CLINICAL LABORATORY, 2015, 61 (1-2) : 53 - 59
  • [30] Performance of the Abbott RealTime and Roche Cobas TaqMan Hepatitis C Virus (HCV) Assays for Quantification of HCV Genotypes
    LaRue, Heidi
    Rigali, Lisa
    Balada-Llasat, Joan-Miquel
    Pancholi, Preeti
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (05) : 1769 - 1772